Multilayer thin-film phantoms for axial contrast transfer function measurement in optical coherence tomography

Anant Agrawal, Chao-Wei Chen, Jigesh Baxi, Yu Chen, and T. Joshua Pfefer  »View Author Affiliations


Biomedical Optics Express, Vol. 4, Issue 7, pp. 1166-1175 (2013)
http://dx.doi.org/10.1364/BOE.4.001166


View Full Text Article

Enhanced HTML    Acrobat PDF (2147 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

In optical coherence tomography (OCT), axial resolution is one of the most critical parameters impacting image quality. It is commonly measured by determining the point spread function (PSF) based on a specular surface reflection. The contrast transfer function (CTF) provides more insights into an imaging system’s resolving characteristics and can be readily generated in a system-independent manner, without consideration for image pixel size. In this study, we developed a test method for determination of CTF based on multi-layer, thin-film phantoms, evaluated using spectral- and time-domain OCT platforms with different axial resolution values. Phantoms representing six spatial frequencies were fabricated and imaged. The fabrication process involved spin coating silicone films with precise thicknesses in the 8-40 μm range. Alternating layers were doped with a specified concentration of scattering particles. Validation of layer optical properties and thicknesses were achieved with spectrophotometry and stylus profilometry, respectively. OCT B-scans were used to calculate CTFs and results were compared with convetional PSF measurements based on specular reflections. Testing of these phantoms indicated that our approach can provide direct access to axial resolution characteristics highly relevant to image quality. Furthermore, tissue phantoms based on our thin-film fabrication approach may have a wide range of additional applications in optical imaging and spectroscopy.

© 2013 OSA

OCIS Codes
(110.3000) Imaging systems : Image quality assessment
(110.4850) Imaging systems : Optical transfer functions
(170.4500) Medical optics and biotechnology : Optical coherence tomography
(350.4800) Other areas of optics : Optical standards and testing

ToC Category:
Optical Coherence Tomography

History
Original Manuscript: April 9, 2013
Revised Manuscript: May 28, 2013
Manuscript Accepted: May 29, 2013
Published: June 14, 2013

Citation
Anant Agrawal, Chao-Wei Chen, Jigesh Baxi, Yu Chen, and T. Joshua Pfefer, "Multilayer thin-film phantoms for axial contrast transfer function measurement in optical coherence tomography," Biomed. Opt. Express 4, 1166-1175 (2013)
http://www.opticsinfobase.org/boe/abstract.cfm?URI=boe-4-7-1166


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. M. Zysk, F. T. Nguyen, A. L. Oldenburg, D. L. Marks, and S. A. Boppart, “Optical coherence tomography: a review of clinical development from bench to bedside,” J. Biomed. Opt.12(5), 051403 (2007). [CrossRef] [PubMed]
  2. A. Agrawal, M. A. Gavrielides, S. Weininger, K. Chakrabarti, and T. J. Pfefer, “Regulatory perspectives and research activities at the FDA on the use of phantoms with in vivo diagnostic devices,” Proc. SPIE6870, 687005, 687005-8 (2008). [CrossRef]
  3. G. Lamouche, B. F. Kennedy, K. M. Kennedy, C. E. Bisaillon, A. Curatolo, G. Campbell, V. Pazos, and D. D. Sampson, “Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography,” Biomed. Opt. Express3(6), 1381–1398 (2012). [CrossRef] [PubMed]
  4. B. W. Pogue and M. S. Patterson, “Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry,” J. Biomed. Opt.11(4), 041102 (2006). [CrossRef] [PubMed]
  5. A. Agrawal, T. J. Pfefer, N. Gilani, and R. Drezek, “Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom,” Opt. Lett.35(13), 2269–2271 (2010). [CrossRef] [PubMed]
  6. P. D. Woolliams, R. A. Ferguson, C. Hart, A. Grimwood, and P. H. Tomlins, “Spatially deconvolved optical coherence tomography,” Appl. Opt.49(11), 2014–2021 (2010). [CrossRef] [PubMed]
  7. P. D. Woolliams and P. H. Tomlins, “Estimating the resolution of a commercial optical coherence tomography system with limited spatial sampling,” Meas. Sci. Technol.22(6), 065502 (2011). [CrossRef]
  8. G. V. Gelikonov, L. S. Dolin, E. A. Sergeeva, and I. V. Turchin, “Multiple backscattering effects in optical coherence tomography images of layered turbid media,” Radiophys. Quantum Electron.46(7), 565–576 (2003). [CrossRef]
  9. R. K. Wang, “Signal degradation by multiple scattering in optical coherence tomography of dense tissue: a Monte Carlo study towards optical clearing of biotissues,” Phys. Med. Biol.47(13), 2281–2299 (2002). [CrossRef] [PubMed]
  10. T. G. van Leeuwen, D. J. Faber, and M. C. Aalders, “Measurement of the axial point spread function in scattering media using single-mode fiber-based optical coherence tomography,” IEEE J. Sel. Top. Quantum Electron.9(2), 227–233 (2003). [CrossRef]
  11. D. M. de Bruin, R. H. Bremmer, V. M. Kodach, R. de Kinkelder, J. van Marle, T. G. van Leeuwen, and D. J. Faber, “Optical phantoms of varying geometry based on thin building blocks with controlled optical properties,” J. Biomed. Opt.15(2), 025001 (2010). [CrossRef] [PubMed]
  12. R. Y. Gu, K. L. Lurie, M. Pipes, and A. K. Ellerbee, “Variable-sized bar targets for characterizing three-dimensional resolution in OCT,” Biomed. Opt. Express3(9), 2317–2325 (2012). [CrossRef] [PubMed]
  13. A. Curatolo, B. F. Kennedy, and D. D. Sampson, “Structured three-dimensional optical phantom for optical coherence tomography,” Opt. Express19(20), 19480–19485 (2011). [CrossRef] [PubMed]
  14. R. C. Chang, P. Johnson, C. M. Stafford, and J. Hwang, “Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials,” Biomed. Opt. Express3(6), 1326–1339 (2012). [CrossRef] [PubMed]
  15. IEC International Standard 61223–2-6, “Evaluation and routine testing in medical imaging departments – Part 2–6: Constancy tests – Imaing performance of computed tomography X-ray equipment” (International Electrotechnical Commission, Geneva, Switzerland, 2006).
  16. U. E. K. Wolf-Schnurrbusch, L. Ceklic, C. K. Brinkmann, M. E. Iliev, M. Frey, S. P. Rothenbuehler, V. Enzmann, and S. Wolf, “Macular thickness measurements in healthy eyes using six different optical coherence tomography instruments,” Invest. Ophthalmol. Vis. Sci.50(7), 3432–3437 (2009). [CrossRef] [PubMed]
  17. M. Hammer, D. Schweitzer, E. Thamm, and A. Kolb, “Optical properties of ocular fundus tissues determined by optical coherence tomography,” Opt. Commun.186(1-3), 149–153 (2000). [CrossRef]
  18. M. Hammer, A. Roggan, D. Schweitzer, and G. Müller, “Optical properties of ocular fundus tissues--an in vitro study using the double-integrating-sphere technique and inverse Monte Carlo simulation,” Phys. Med. Biol.40(6), 963–978 (1995). [CrossRef] [PubMed]
  19. P. Ciullo, Industrial Minerals and Their Uses: A Handbook and Formulary (Noyes, 1996).
  20. J. H. Koschwanez, R. H. Carlson, and D. R. Meldrum, “Thin PDMS films using long spin times or tert-butyl alcohol as a solvent,” PLoS ONE4(2), e4572 (2009). [CrossRef] [PubMed]
  21. D. X. Hammer, N. V. Iftimia, R. D. Ferguson, C. E. Bigelow, T. E. Ustun, A. M. Barnaby, and A. B. Fulton, “Foveal fine structure in retinopathy of prematurity: an adaptive optics Fourier domain optical coherence tomography study,” Invest. Ophthalmol. Vis. Sci.49(5), 2061–2070 (2008). [CrossRef] [PubMed]
  22. A. Agrawal, S. Huang, A. Wei Haw Lin, M. H. Lee, J. K. Barton, R. A. Drezek, and T. J. Pfefer, “Quantitative evaluation of optical coherence tomography signal enhancement with gold nanoshells,” J. Biomed. Opt.11(4), 041121 (2006). [CrossRef] [PubMed]
  23. A. A. Michelson, Studies in Optics (Univ. Chicago Press, 1927).
  24. E. Hecht, Optics (Addison-Wesley, 1998).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.