Abstract

Point-scanning reflectance confocal microscopes continue to be successfully translated for detection of skin cancer. Line-scanning, with the use of a single scanner and a linear-array detector, offers a potentially smaller, simpler and lower cost alternative approach, to accelerate widespread dissemination into the clinic. However, translation will require an understanding of imaging performance deep within scattering and aberrating human tissues. We report the results of an investigation of the performance of a full-pupil line-scanning reflectance confocal microscope in human skin and oral mucosa, in terms of resolution, optical sectioning, contrast, signal-to-noise ratio, imaging and the effect of speckle noise.

© 2011 OSA

OCIS Codes
(120.3890) Instrumentation, measurement, and metrology : Medical optics instrumentation
(120.4570) Instrumentation, measurement, and metrology : Optical design of instruments
(170.1790) Medical optics and biotechnology : Confocal microscopy
(180.1790) Microscopy : Confocal microscopy
(180.5810) Microscopy : Scanning microscopy

ToC Category:
Microscopy

History
Original Manuscript: May 2, 2011
Revised Manuscript: June 14, 2011
Manuscript Accepted: June 21, 2011
Published: June 27, 2011

Virtual Issues
Advances in Optics for Biotechnology, Medicine, and Surgery (2011) Biomedical Optics Express

Citation
Bjorg Larson, Sanjeewa Abeytunge, and Milind Rajadhyaksha, "Performance of full-pupil line-scanning reflectance confocal microscopy in human skin and oral mucosa in vivo," Biomed. Opt. Express 2, 2055-2067 (2011)
http://www.opticsinfobase.org/boe/abstract.cfm?URI=boe-2-7-2055


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. S. G. Gonzalez, M. Gill, and A. C. Halpern, eds., Reflectance Confocal Microscopy of Cutaneous Tumors—An Atlas with Clinical, Dermoscopic and Histological Correlations (Informa Healthcare, London, 2008).
  2. C. S. Chen, M. Elias, K. Busam, M. Rajadhyaksha, and A. A. Marghoob, “Multimodal in vivo optical imaging, including confocal microscopy, facilitates presurgical margin mapping for clinically complex lentigo maligna melanoma,” Br. J. Dermatol. 153(5), 1031–1036 (2005). [CrossRef] [PubMed]
  3. D. S. Gareau, J. K. Karen, S. W. Dusza, M. Tudisco, K. S. Nehal, and M. Rajadhyaksha, “Sensitivity and specificity for detecting basal cell carcinomas in Mohs excisions with confocal fluorescence mosaicing microscopy,” J. Biomed. Opt. 14(3), 034012 (2009). [CrossRef] [PubMed]
  4. J. K. Karen, D. S. Gareau, S. W. Dusza, M. Tudisco, M. Rajadhyaksha, and K. S. Nehal, “Detection of basal cell carcinomas in Mohs excisions with fluorescence confocal mosaicing microscopy,” Br. J. Dermatol. 160(6), 1242–1250 (2009). [CrossRef] [PubMed]
  5. A. Scope, U. Mahmood, D. S. Gareau, M. Kenkre, J. A. Lieb, K. S. Nehal, and M. Rajadhyaksha, “In vivo reflectance confocal microscopy of shave biopsy wounds: feasibility of intraoperative mapping of cancer margins,” Br. J. Dermatol. 163(6), 1218–1228 (2010). [CrossRef] [PubMed]
  6. S. Nori, F. Rius-Díaz, J. Cuevas, M. Goldgeier, P. Jaen, A. Torres, and S. G. González, “Sensitivity and specificity of reflectance-mode confocal microscopy for in vivo diagnosis of basal cell carcinoma: a multicenter study,” J. Am. Acad. Dermatol. 51(6), 923–930 (2004). [CrossRef] [PubMed]
  7. G. Pellacani, P. Guitera, C. Longo, M. Avramidis, S. Seidenari, and S. Menzies, “The impact of in vivo reflectance confocal microscopy for the diagnostic accuracy of melanoma and equivocal melanocytic lesions,” J. Invest. Dermatol. 127(12), 2759–2765 (2007). [PubMed]
  8. P. Guitera, G. Pellacani, C. Longo, S. Seidenari, M. Avramidis, and S. W. Menzies, “In vivo reflectance confocal microscopy enhances secondary evaluation of melanocytic lesions,” J. Invest. Dermatol. 129(1), 131–138 (2009). [CrossRef] [PubMed]
  9. A. Gerger, R. Hofmann-Wellenhof, U. Langsenlehner, E. Richtig, S. Koller, W. Weger, V. Ahlgrimm-Siess, M. Horn, H. Samonigg, and J. Smolle, “In vivo confocal laser scanning microscopy of melanocytic skin tumours: diagnostic applicability using unselected tumour images,” Br. J. Dermatol. 158(2), 329–333 (2008). [CrossRef] [PubMed]
  10. P. Guitera, G. Pellacani, K. A. Crotty, R. A. Scolyer, L. X. Li, S. Bassoli, M. Vinceti, H. Rabinovitz, C. Longo, and S. W. Menzies, “The impact of in vivo reflectance confocal microscopy on the diagnostic accuracy of lentigo maligna and equivocal pigmented and nonpigmented macules of the face,” J. Invest. Dermatol. 130(8), 2080–2091 (2010). [CrossRef] [PubMed]
  11. C. J. Koester, “Scanning mirror microscope with optical sectioning characteristics: applications in ophthalmology,” Appl. Opt. 19(11), 1749–1757 (1980). [CrossRef] [PubMed]
  12. G. Brakenhoff and K. Visscher, “Scanning mirror microscope with optical sectioning characteristics: applications in ophthalmology,” J. Microsc. 165, 139–146 (1992).
  13. Y. S. Sabharwal, A. R. Rouse, L. Donaldson, M. F. Hopkins, and A. F. Gmitro, “Slit-scanning confocal microendoscope for high-resolution in vivo imaging,” Appl. Opt. 38(34), 7133–7144 (1999). [CrossRef] [PubMed]
  14. A. A. Tanbakuchi, A. R. Rouse, J. A. Udovich, K. D. Hatch, and A. F. Gmitro, “Clinical confocal microlaparoscope for real-time in vivo optical biopsies,” J. Biomed. Opt. 14(4), 044030 (2009). [CrossRef] [PubMed]
  15. K. B. Im, S. Han, H. Park, D. Kim, and B. M. Kim, “Simple high-speed confocal line-scanning microscope,” Opt. Express 13(13), 5151–5156 (2005). [CrossRef] [PubMed]
  16. R. Wolleschensky, B. Zimmermann, and M. Kempe, “High-speed confocal fluorescence imaging with a novel line scanning microscope,” J. Biomed. Opt. 11(6), 064011 (2006). [CrossRef] [PubMed]
  17. D. X. Hammer, “Hand-held digital line-scanning laser ophthalmoscope (LSLO),” Proc. SPIE 5314, 161–169 (2004). [CrossRef]
  18. P. J. Dwyer, C. A. DiMarzio, and M. Rajadhyaksha, “Confocal theta line-scanning microscope for imaging human tissues,” Appl. Opt. 46(10), 1843–1851 (2007). [CrossRef] [PubMed]
  19. D. S. Gareau, S. Abeytunge, and M. Rajadhyaksha, “Line-scanning reflectance confocal microscopy of human skin: comparison of full-pupil and divided-pupil configurations,” Opt. Lett. 34(20), 3235–3237 (2009). [CrossRef] [PubMed]
  20. T. R. Crimmins, “Geometric filter for speckle reduction,” Appl. Opt. 24(10), 1438 (1985). [CrossRef] [PubMed]
  21. S. L. Jacques, “Polarized light imaging of biological tissues,” in Handbook of Biomedical Optics, D. Boas, C. Pitris, and N. Ramanujam, eds. (CRC Press, Boca Raton, FL, 2011), pp. 649–669.
  22. T. Wilson and A. R. Carlini, “Size of the detector in confocal imaging systems,” Opt. Lett. 12(4), 227–229 (1987). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: AVI (3684 KB)     
» Media 2: AVI (2790 KB)     

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited