Tympanic membrane contour measurement with two source positions in digital holographic interferometry

Silvino M. Solís, María del S. Hernández-Montes, and Fernando M. Santoyo  »View Author Affiliations


Biomedical Optics Express, Vol. 3, Issue 12, pp. 3203-3210 (2012)
http://dx.doi.org/10.1364/BOE.3.003203


View Full Text Article

Acrobat PDF (1159 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

The data acquisition from the shape of an object is a must to complete its quantitative displacement measurement analysis. Over the past years whole field of view optical non-invasive testing has been widely used in many areas, from industrial ones to, for instance, biomedical research topics. To measure the surface contour from the tympanic membrane (TM) of ex-vivo cats digital holographic interferometry (DHI) is used in combination with a two-illumination positions method: the shape is directly measured from the phase change between two source positions by means of a digital Fourier transform method. The TM shape data in conjunction with its displacement data renders a complete and accurate description of the TM deformation, a feature that no doubt will serve to better comprehend the hearing process. Acquiring knowledge from the tissue shape indicates a mechanical behavior and, indirectly, an alteration in the physiological structure due to middle ear diseases or damages in the tissue that can deteriorate sound transmission. The TM shape contour was successfully measured by using two source positions within DHI showing that the TM has a conical shape. Its maximum depth was found to be 2 mm, considering the umbo as the reference point with respect to the TM annulus plane, where the setup is arranged in such a manner that it is capable of measuring a height of up to 7 mm.

© 2012 OSA

OCIS Codes
(090.0090) Holography : Holography
(120.0120) Instrumentation, measurement, and metrology : Instrumentation, measurement, and metrology
(170.0170) Medical optics and biotechnology : Medical optics and biotechnology

ToC Category:
Otolaryngology

History
Original Manuscript: September 11, 2012
Revised Manuscript: October 18, 2012
Manuscript Accepted: November 4, 2012
Published: November 8, 2012

Citation
Silvino M. Solís, María del S. Hernández-Montes, and Fernando M. Santoyo, "Tympanic membrane contour measurement with two source positions in digital holographic interferometry," Biomed. Opt. Express 3, 3203-3210 (2012)
http://www.opticsinfobase.org/boe/abstract.cfm?URI=boe-3-12-3203


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. M. Takeda, H. Ina, and S. Kobayashi, “Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry,” J. Opt. Soc. Am.72(1), 156–160 (1982). [CrossRef]
  2. K. Creath, “Holographic contour and deformation measurement using a 1.4 million element detector array,” Appl. Opt.28(11), 2170–2175 (1989). [CrossRef] [PubMed]
  3. S. Seebacher, W. Osten, and W. Jüptner, “Measuring shape and deformation of small objects using digital holography,” Proc. SPIE3479, 104–115 (1998). [CrossRef]
  4. G. Pedrini, P. Fröning, H. J. Tiziani, and F. Mendoza Santoyo, “Shape measurement of microscopic structures using digital holograms,” Opt. Commun.164(4-6), 257–268 (1999). [CrossRef]
  5. F. Chen, G. M. Brown, and M. Song, “Overview of three-dimensional shape measurement using optical methods,” Opt. Eng.39(1), 10–22 (2000). [CrossRef]
  6. I. Yamaguchi, S. Ohta, and J.-i. Kato, “Surface contouring by phase-shifting digital holography,” Opt. Lasers Eng.36(5), 417–428 (2001). [CrossRef]
  7. C. Quan, W. Chen, and C. J. Tay, “Shape measurement by multi-illumination method in digital holographic Interferometry,” Opt. Commun.281(15-16), 3957–3964 (2008). [CrossRef]
  8. C. M. Vest, Holographic Interferometry (Wiley, New York, 1979).
  9. T. Kreis, “Digital holographic interference-phase measurement using the Fourier-transform method,” J. Opt. Soc. Am. A3(6), 847–855 (1986). [CrossRef]
  10. P. K. Rastogi, Principles of Holographic Interferometry and Speckle Metrology (Springer-Verlag, Berlin, 2000).
  11. G. Pedrini, W. Osten, and M. E. Gusev, “High-speed digital holographic interferometry for vibration measurement,” Appl. Opt.45(15), 3456–3462 (2006). [CrossRef] [PubMed]
  12. C. Furlong, J. J. Rosowski, N. Hulli, and M. E. Ravicz, “Preliminary analyses of tympanic-membrane motion from holographic measurements,” Strain45(3), 301–309 (2009). [CrossRef] [PubMed]
  13. M. del Socorro Hernández-Montes, C. Furlong, J. J. Rosowski, N. Hulli, E. Harrington, J. T. Cheng, M. E. Ravicz, and F. M. Santoyo, “Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranes,” J. Biomed. Opt.14(3), 034023 (2009). [CrossRef] [PubMed]
  14. J. J. Rosowski, J. T. Cheng, M. E. Ravicz, N. Hulli, M. Hernandez-Montes, E. Harrington, and C. Furlong, “Computer-assisted time-averaged holograms of the motion of the surface of the mammalian tympanic membrane with sound stimuli of 0.4-25 kHz,” Hear. Res.253(1-2), 83–96 (2009). [CrossRef] [PubMed]
  15. G. Volandri, F. Di Puccio, P. Forte, and C. Carmignani, “Biomechanics of the tympanic membrane,” J. Biomech.44(7), 1219–1236 (2011). [CrossRef] [PubMed]
  16. J. Aernouts, J. R. M. Aerts, and J. J. J. Dirckx, “Mechanical properties of human tympanic membrane in the quasi-static regime from in situ point indentation measurements,” Hear. Res.290(1-2), 45–54 (2012). [CrossRef] [PubMed]
  17. W. F. Decraemer and W. R. J. Funnelli, “Anatomical and Mechanical properties of the tympanic membrane,” in Chronic otitis Media. Pathogenesis-Oriented Therapeutic Management, E.D. Ars, ed. (Kugler, 2008).
  18. W. R. J. Funnell and W. F. Decraemer, “On the incorporation of moiré shape measurements in finite-element models of the cat eardrum,” J. Acoust. Soc. Am.100(2), 925–932 (1996). [CrossRef] [PubMed]
  19. J. J. J. Dirckx and W. F. Decraemer, “Interferometer for eardrum shape measurement, based on projection of straight line rulings,” Lasers Med. Sci.15(2), 131–139 (2000). [CrossRef]
  20. R. A. Martínez-Celorio, J. J. J. Dirckx, J. A. N. Buytaert, L. Martí-López, and W. Decraemer, “Modified temporal-phase-unwrapping method for measuring in real time the out-of-plane displacements of the tympanic membrane of mongolian gerbil,” Optik (Stuttg.)119(16), 783–787 (2008). [CrossRef]
  21. J. J. J. Dirckx, J. A. N. Buytaert, and S. A. M. Van derJeught, “Implementation of phase-shifting moiré profilometry on a low-cost commercial data projector,” Opt. Lasers Eng.48(2), 244–250 (2010). [CrossRef]
  22. I. Yamaguchi, J. I. Kato, and H. Matsuzaki, “Measurement of surface shape and deformation by phase-shifting image digital holography,” Opt. Eng.42(5), 1267–1271 (2003). [CrossRef]
  23. M. S. Hernández-Montes, F. Mendoza Santoyo, C. Pérez López, S. Muñoz Solís, and J. Esquivel, “Digital holographic -interferometry applied to the study of tympanic membrane displacements,” Opt. Lasers Eng.49(6), 698–702 (2011). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited