OSA's Digital Library

Chinese Optics Letters

Chinese Optics Letters

| PUBLISHED MONTHLY BY CHINESE LASER PRESS AND DISTRIBUTED BY OSA

  • Vol. 6, Iss. 12 — Dec. 1, 2008
  • pp: 910–912

Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference

Utkarsh Sharma and Jin U. Kang  »View Author Affiliations


Chinese Optics Letters, Vol. 6, Issue 12, pp. 910-912 (2008)


View Full Text Article

Acrobat PDF (597 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously.

© 2008 Chinese Optics Letters

OCIS Codes
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(170.3890) Medical optics and biotechnology : Medical optics instrumentation
(170.4500) Medical optics and biotechnology : Optical coherence tomography

Citation
Utkarsh Sharma and Jin U. Kang, "Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference," Chin. Opt. Lett. 6, 910-912 (2008)
http://www.opticsinfobase.org/col/abstract.cfm?URI=col-6-12-910


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. M. J. Mack, J. American Medical Association 285, 568 (2001).
  2. B. L. Davies, W. S. Ng, and R. D. Hibberd, Robotica 11, 561 (1993).
  3. F. Pierrot, E. Dombre, E. Dégoulange, L. Urbain, P. Caron, S. Boudet, J. Gariépy, and J. Mégnien, Medical Image Analysis 3, 285 (1999).
  4. http://www.intuitivesurgical.com/products/index.aspx (November 1, 2008).
  5. P. Kanzanzides, J. Zuhars, B Mittelstadt, and R. H. Taylor, in Proceeding of IEEE Intl. Conf. on Robotics and Automation Nice, France (1992).
  6. F. Pierrot, E. Dombre, L. Teot, and E. Dégoulange, in Proceedings of IEEE Intl. Conf. on Robotics and Automation San Francisco, CA, April 2000.
  7. A. B. Vakhtin, D. J. Kane, W. R. Wood, and K. A. Peterson, Appl. Opt. 42, 6953 (2003).
  8. P. Casaubieilh, H. D. Ford, and R. P. Tatam, Proc. SPIE 5502, 338 (2004).
  9. U. Sharma, N. M. Fried, and J. U. Kang, IEEE J. Sel. Top. Quantum Electron. 11, 799 (2005).
  10. U. Sharma and J. U. Kang, Rev. Sci. Instrum. 78, 113102 (2007).
  11. J. U. Kang and U. Sharma, CLEO 2006, CTuG3 (2006).
  12. J. A. Izatt, M. R. Hee, E. A. Swanson, C. P. Lin, D. Huang, J. S. Schuman, C. A. Puliafito, and J. G. Fujimoto, Arch Ophthalmol 112, 1584 (1994).
  13. M. R. Bryant, K. Szerenyi, H. Schmotzer, and P. J. McDonnell, Investigative Ophthalmology and Visual Science 35, 3022 (1994).

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited