Abstract
A modified asymmetrical Czerny-Turner arrangement with a fixed plane grating is proposed to correct aberrations over a broadband spectral range by analyzing the dependence of aberrations for different wavelengths. The principle of design is deduced in detail. We compare the performance of this modified Czerny-Turner imaging spectrometer with that of the existing Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example. The excellent performance of the modified imaging spectrometer is confirmed by simulation with ZEMAX software.