Abstract

In this paper, we present an N-ocular imaging system with tilted image sensors to improve the depth resolution for objects under fixed system resource constraints. A nonplanar arrangement of image sensors enables one to improve the system performance due to the increase in the common field of view (FOV). We analyze the depth resolution based on the two point sources resolution criterion as a function of sensing parameters such as the number of cameras, the number of pixels, parallax, pixel size, and focal length. We carry out Monte Carlo simulations in the analysis. The results indicate that the proposed method may improve the common FOV zone and thus provide improved depth resolution for N-ocular imaging system when the objects are not very far from the sensors.

© 2012 IEEE

Citation
Donghak Shin and Bahram Javidi, "Resolution Analysis of N-Ocular Imaging Systems With Tilted Image Sensors," J. Display Technol. 8, 529-533 (2012)
http://www.opticsinfobase.org/jdt/abstract.cfm?URI=jdt-8-9-529


Sort:  Year  |  Journal  |  Reset

References

  1. G. Lippmann, "Epreuves reversibles donnant la sensation du relief," J. Phys. 7, 821-825 (1908).
  2. S. Manolache, A. Aggoun, M. McCormick, N. Davies, S. Y. Kung, "Analytical model of a three-dimensional integral image recording system that uses circular- and hexagonal-based spherical surface microlenses," J. Opt. Soc. Amer. A. 18, 1814-1821 (2001).
  3. F. Okano, J. Arai, K. Mitani, M. Okui, "Real-time integral imaging based on extremely high resolution video system," Proc. IEEE 94, 490-501 (2006).
  4. A. Stern, B. Javidi, "Three-dimensional image sensing, visualization, and processing using integral imaging," Proc. IEEE 94, 591-607 (2006).
  5. C. B. Burckhardt, "Optimum parameters and resolution limitation of integral photography," J. Opt. Soc. Amer. 58, 71-76 (1968).
  6. J. Y. Son, B. Javidi, "Three-dimensional imaging methods based on multiview images," J. Display Technol. 1, 125-140 (2005).
  7. H. Hoshino, F. Okano, H. Isono, I. Yuyama, "Analysis of resolution limitation of integral photography," J. Opt. Soc. Amer. A 15, 2059-2065 (1998).
  8. D. Shin, M. Daneshpanah, B. Javidi, "Generalization of 3D N-ocular imaging systems under fixed resource constraints," Optics Letters 37, 19-21 (2012).
  9. R. Martinez-Cuenca, G. Saavedra, M. Martinez-Corral, B. Javidi, "Progress in 3-D multiperspective display by integral imaging," Proc. IEEE 97, 1067-1077 (2009).
  10. M. Daneshpanah, B. Javidi, E. Watson, "Three dimensional integral imaging with randomly distributed sensors," Opt. Express 16, 6368-6377 (2008).

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited