Effects of Illumination Level on Visual Performance and Fatigue

ERNST SIMONSON and JOSEF BROZEK  »View Author Affiliations


JOSA, Vol. 38, Issue 4, pp. 384-397 (1948)
http://dx.doi.org/10.1364/JOSA.38.000384


View Full Text Article

Acrobat PDF (1592 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

The purpose of this study was to investigate the relation of the level of illumination intensity to performance and fatigue in visual work. The question of illumination requirements is of considerable importance from the point of view of physiological optics, industrial physiology, and public health. Yet a large part of the research done in the past leaves much to be desired in regard to general approach and specific testing techniques as well as experimental analysis and statistical evaluation. In the present series six illumination levels (2, 5, 15, 50, 100, and 300 footcandles) were studied in repeated experiments in six normal subjects. The work task involved recognition of fine details (letters) and reproduced the essential features of a conveyor inspection operation. In addition to the studying of various criteria of work performance and their change in the course of 2 hours of work, a large battery of visual tests was applied before and after the work so as to characterize the degree of fatigue. Varied illumination affected the performance more than the functional criteria of fatigue. Only one function, the recognition time for stimuli of threshold size, showed a decreasing degree of fatigue up to 300 ft.-c, all other variables, including performance, which changed with a changing level of illumination showed an optimum at 100 ft.-c. The demonstration of an optimum level of illumination makes highly questionable the current practice of recommending “minimum” levels of illumination for industrial jobs, since deterioration of performance and increase in fatigue may result when the optimal level is exceeded. The optimum of 100 ft.-c for the present strenuous visual task is at or below the minimum which should be recommended on the basis of the code of the Illuminating Engineering Society.

Citation
ERNST SIMONSON and JOSEF BROZEK, "Effects of Illumination Level on Visual Performance and Fatigue," J. Opt. Soc. Am. 38, 384-397 (1948)
http://www.opticsinfobase.org/josa/abstract.cfm?URI=josa-38-4-384


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. "American recommended practice of industrial lighting," Illuminating Engineering Society (1942).
  2. J. S. Rogers, Illumination. In "Protecting Plant Manpower," pp. 63–66, U. S. Dept. of Labor, Washington, 1941.
  3. A. D. Brandt and H. E. Seifert, "Illumination, noise and radiant energy," Manual of Industrial Hygiene (W. M. Gafafer) (W. B. Saunders, Philadelphia, 1943), pp. 353–372
  4. Committee on Industrial and School Lighting, "Report on lighting in the textile industry," Trans. Illum. Eng. Soc. 32, 247 (1937).
  5. Committee on Industrial and School Lighting, "Report on lighting in the shoe manufacturing company," Trans. Illum. Eng. Soc. 32, 289 (1937).
  6. Committee on Industrial and School Lighting, "Progress report on the lighting in the printing industry," Trans. Illum. Eng. Soc. 31, 277 (1936).
  7. Committee on Industrial and School Lighting, "Report on lighting in the candy manufacturing industry," Trans. Illum. Eng. Soc. 32, 483 (1937).
  8. Committee on Industrial and School Lighting, "Studies in lighting of intricate production, assembly and inspection processes," Trans. Illum. Eng. Soc. 32, 1019 (1937).
  9. Committee on Industrial and School Lighting, "Lighting for silk and rayon throwing and wide goods weaving," Trans. Ilium. Eng. Soc. 33, 17 (1938).
  10. Committee on Industrial and School Lighting, "Lighting for the machining of small metal parts," Trans. Illum. Eng. Soc. 34, 21 (1939).
  11. Committee on Industrial and School Lighting, "Lighting of power presses," Trans. Illum. Eng. Soc. 34, 153 (1939).
  12. M. Luckiesh and F. M. Moss, Te Science of Seeing (D. Van Nostrand Company, Inc., New York, 1938), p. 548.
  13. J. Brozek, E. Simonson, and A. Keys, "A work test for quantitative study of visual performance and fatigue," J. App. Psychol. 31, 519 (1947).
  14. H. C. Weston, "The relation between illumination and industrial efficiency: I. The effect of the size of work." Joint Rep. Industr. Health Res. Board and Illum. Res. Comm. (London) (1935).
  15. F. N. Freeman, "An investigation of the illumination requirements of school buildings," National Education Association: Report of Committee on School House Planning, 90 (1925).
  16. H. J. Ströer, "Rationalisierung der Arbeitsplatzbeleuchtung," Industr. Psychotechnik 3, 289 (1926).
  17. J. Brozek, E. Simonson, and A. Keys, "Quantitative analysis of voluntary eye movements," (to be published).
  18. J. Brozek, E. Simonson, W. J. Bushard, and J. H. Peterson, "Effects of practice and the consistency of repeated measurements of accommodation and vergence," Am. J. Ophthal. (in press).
  19. J. Brozek, E. Simonson, and H. Alexander, "Statistical comparison of changes in fitness characteristics," (in press).M. A. Tinker, "Effect of visual adaptation upon intensity of light preferred for reading," Am. J. Psychol. 54, 559 (1941).
  20. M. A. Tinker, "Effect of visual adaptation upon intensity of light preferred for reading," Am. J. Psychol. 54, 559 (1941).
  21. E. Simonson, "L'adaptation au travail physique," Le Travail Hunmain 4, 129 (1936).
  22. M. Luckiesh and F. M. Moss, "Fatigue of convergence induced by reading as a function of illumination intensity," Am. J. Ophthal. 18, 319 (1935).
  23. H. Schulz, "Die Ermüldung des Auges," Industr. Psychotechnik 2, 5 (1925).
  24. C. E. Ferree and G. Rand, "The efficiency of the eye under different conditions of lighting: the effect of varying the distribution factors and intensity," Trans. Illum. Eng. Soc. 10, 407 (1915).
  25. M. A. Tinker, "Illumination standards," Am. J. Pub. Health 36, 963 (1946).
  26. T. A. Ryan, "Work and effort: the psychology of efficiency," (in press).
  27. L. R. White, R. H. Britten, J. H. Ives, and L. R. Thompson, "Studies in illumination II. Relationship of illumination to ocular efficiency and ocular fatigue among the letter separators in the Chicago post office," Public Health Bull. No. 181, Washington (1929).
  28. A. C. Hoffman, "Luckiesh and Moss on reading illumination," J. App. Psychol. 31, 44 (1947).
  29. C. A. Oakley, Men at Work (University of London Press, London, 1946), p. 301.
  30. H. C. Weston and A. K. Taylor, "The relation between illumination and efficiency in fine work (typesetting by hand)," Joint Rep. Industr. Fatigue Res. Board and Ilium. Res. Comm., (London) (1926).
  31. C. E. Snow, "A discussion of the relation of illumination intensity to productive efficiency," Tech. Eng. News 8, 257 (1927).
  32. M. A. Tinker, "Validity of frequency of blinking as a criterion of readability," J. Exp. Psychol. 36, 453 (1937).
  33. R. A. McFarland, A. H. Holway, and L. M. Hurvich, "Studies of visual fatigue," Harvard Univ. Graduate School of Business Administration (1942).
  34. R. A. McFarland, C. A. Knehr, and C. Berens, "Metabolism and pulse rate as related to reading under high and low levels of illumination," J. Exp. Psychol. 25, 65 (1939).
  35. M. E. Bitterman, "Heart rate and frequency of blinking as indices of visual efficiency," J. Exp. Psychol. 35, 279 (1945).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited