OSA's Digital Library

Journal of the Optical Society of America

Journal of the Optical Society of America

  • Vol. 39, Iss. 9 — Sep. 1, 1949
  • pp: 766–770

The Coefficient of Specific Resolution of the Human Eye for Foucault Test Objects Viewed through Circular Apertures

HOWARD S. COLEMAN, MADELINE F. COLEMAN, DAVID L. FRIIGE, and SAMUEL W. HARDING  »View Author Affiliations


JOSA, Vol. 39, Issue 9, pp. 766-770 (1949)
http://dx.doi.org/10.1364/JOSA.39.000766


View Full Text Article

Acrobat PDF (621 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A study has been made of the resolving power of the human eye for Foucault test objects of different inherent contrast viewed through circular artificial pupil stops ranging from 0.30 of a millimeter to 7.0 millimeters in diameter. Two methods were used to make the resolution measurements. The first consisted of viewing the test objects through circular apertures in 10-mil blackened brass shim stock disks placed about 3 millimeters from the observer’s eye. Provision was made for illuminating the test objects both with tungsten lamps and with mercury arcs. The second method involved the use of test objects viewed in collimated light by means of a telescopic system for which the exit pupil could be varied from 0.40 of a millimeter to 2.0 millimeters. Both methods used equipment embodying the basic principles of the K.D.C. apparatus. The study included resolution measurements for rectangular and square Foucault test objects consisting of straight parallel black and white bands having an inherent contrast of approximately 94 percent. The coefficient of specific resolution was computed for test objects having lower values of inherent contrast. The resolution measurements, totaling over 100,000, were made by thirty-two different observers ranging from 18 to 76 years in age. The coefficient of specific resolution was found to be practically independent of age and observer for artificial pupil stops less than 0.75 of a millimeter in diameter. This suggests an effective consistency of the contrast threshold of the human retina as far as resolution measurements are concerned and indicates that the diffraction of light at the pupil stop is the primary factor controlling resolution. For artificial pupil stops of larger diameter, the coefficient of specific resolution was found to depend upon the individual observer but only with a maximum variation among the observers used of 30 percent. The composition of the test object was found to influence the coefficient of specific resolution to a certain extent with an indication that the best resolution was obtainable with test objects having the greatest number of elements.

Citation
HOWARD S. COLEMAN, MADELINE F. COLEMAN, DAVID L. FRIIGE, and SAMUEL W. HARDING, "The Coefficient of Specific Resolution of the Human Eye for Foucault Test Objects Viewed through Circular Apertures," J. Opt. Soc. Am. 39, 766-770 (1949)
http://www.opticsinfobase.org/josa/abstract.cfm?URI=josa-39-9-766


Sort:  Author  |  Journal  |  Reset

References

  1. H. S. Coleman and S. W. Harding, J. Opt. Soc. Am. 37, 263 (1947).
  2. H. S. Coleman and M. F. Coleman, J. Opt. Soc Am. 37, 572 (1947).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited