OSA's Digital Library

Journal of the Optical Society of America

Journal of the Optical Society of America

  • Vol. 45, Iss. 5 — May. 1, 1955
  • pp: 393–394

Use of the Sénarmont Compensator for Measuring Double Refraction of Flow

ALEXANDER RICH  »View Author Affiliations


JOSA, Vol. 45, Issue 5, pp. 393-394 (1955)
http://dx.doi.org/10.1364/JOSA.45.000393


View Full Text Article

Acrobat PDF (360 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

When the Sénarmont compensator is used for measuring birefringence in double refraction of flow instruments, the cross of isocline is seen to undergo a scissors-like collapsing motion as the analyzer is rotated. The position and intensity of the collapsing cross have been calculated, and are in agreement with experimental observations. From this analysis, we can directly demonstrate the end-point sensitivity of the compensator.

Citation
ALEXANDER RICH, "Use of the Sénarmont Compensator for Measuring Double Refraction of Flow," J. Opt. Soc. Am. 45, 393-394 (1955)
http://www.opticsinfobase.org/josa/abstract.cfm?URI=josa-45-5-393


Sort:  Author  |  Journal  |  Reset

References

  1. H. de Sénarmont, Ann. Chim. Phys. (2), 73, 337 (1840).
  2. A. von Muralt and J. T. Edsall, J. Biol. Chem. 89, 315, 351 (1930); Trans. Faraday Soc. 26, 837 (1930).
  3. C. Sadron, J. phys. radium (7), 7, 263 (1936).
  4. R. Signer and H. Gross, Z. Physik. Chem. (A), 165, 161 (1933).
  5. Edsall, Rich, and Goldstein, Rev. Sci. Inst. 23, 695, (1952).
  6. R. Cerf and H. A. Scheraga, Chem. Revs. 51, 185 (1952).
  7. The Sénarmont compensator is described briefly in Crystals and the Polarizing Microscope by N. H. Hartshorne and A. Stuart, London, 1950, Second edition p. 455. More detailed discussions are included in F. Gabler and P. Sokob, Z. f. Instrumentenk 58, 301 (1938); F. Gabler and P. Sokob, Physik. Z. 42, 319 (1941); and H. G. Jerrard, J. Opt. Soc. Am. 38, 35 (1948).
  8. Throughout this discussion, the orientation of the optic axis of the liquid as measured by the angle a is regarded as fixed, and determined by the original positions of the arms of the isocline cross before the analyzer is rotated. Thus a is an angular coordinate in the annulus. The darkened areas Q1 and Q2 move together in the annulus as the analyzer is rotated, but the values of a about the annulus remain unchanged.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.