OSA's Digital Library

Journal of the Optical Society of America

Journal of the Optical Society of America

  • Vol. 53, Iss. 9 — Sep. 1, 1963
  • pp: 1026–1032

Visual Resolution and Contour Interaction

MERTON C. FLOM, FRANK W. WEYMOUTH, and DANIEL KAHNEMAN  »View Author Affiliations


JOSA, Vol. 53, Issue 9, pp. 1026-1032 (1963)
http://dx.doi.org/10.1364/JOSA.53.001026


View Full Text Article

Acrobat PDF (863 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Detecting the position of the gap in a Landolt C is adversely affected by black bars placed tangential to the C and at a certain distance from it. The maximum bar separation affording interaction is proportional to the minimum angle of resolution, even in cases of amblyopia where resolution is presumably not limited by optical spread of the image. It is suggested that this contour interaction is related to the size of the receptive field (and hence to the resolving capacity) associated with the retinal region used to fixate the target.

Citation
MERTON C. FLOM, FRANK W. WEYMOUTH, and DANIEL KAHNEMAN, "Visual Resolution and Contour Interaction," J. Opt. Soc. Am. 53, 1026-1032 (1963)
http://www.opticsinfobase.org/josa/abstract.cfm?URI=josa-53-9-1026


Sort:  Author  |  Journal  |  Reset

References

  1. W. Korte, Z. Psychol. 93, 17 (1923).
  2. R. H. Davage and F. C. Summer, J. Psychol. 30, 191 (1950).
  3. P. Müller, Ophthalmologica (Basel) 121, 143 (1951).
  4. H. Goldmann, discussion in Ref. 3, p. 148.
  5. A. Franceschetti, discussion in Ref. 3, p. 149.
  6. J. H. Prince, Am. J. Optom. and Arch. Am. Acad. Optom. 34, 581 (1957).
  7. E. Averbach and A. S. Coriell, Bell System Tech. J. 40, 309 (1961).
  8. Amblyopia (Greek, "blunt sight") is a loose term applied to cases of low visual acuity not explainable by obvious structural or optical abnormality. It is usually unilateral often being associated with a large difference in refractive error between the two eyes or with a deviation (heterotropia) of the amblyopic eye. Monocular fixation with an amblyopic eye is generally unsteady and often nonfoveal.
  9. An equation which permits calculation of visual efficiency (E) from the minimum angle of resolution (A) is log E=2.0777-0.0771A.
  10. There is no evidence that the basis of amblyopia is unsharp retinal imagery. A small artificial pupil does not improve the acuity of an amblyopic eye. Amblyopes are often quite insistent that imagery with the affected eye is not "blurred" in comparison with the normal eye. Placing an added lens of +0.25 or +0.50 D. before an amblyopic eye will usually evoke a response of "blur."
  11. F. W. Weymouth, Am. J. Ophthalmol. 46, 102 (1958), No. 1, Pt. II
  12. D. H. Hubel and T. N. Wiesel, J. Physiol. (London) 154, 572 (1960).
  13. T. N. Wiesel, J. Physiol. (London) 153, 583 (1960).
  14. D. H. Hubel and T. N. Wiesel, J. Physiol. (London) 160, 106 (1962).
  15. M. C. Flom and F. W. Weymouth, Arch. Ophthalmol. 66, 260 (1961).
  16. J. Lorenz, Arch. Ges. Psychol. 24, 313 (1912).
  17. R. Pauli, Z. Biol. 81, 93 (1924).
  18. J. Nachmias, J. Opt. Soc. Am. 51, 761 (1961).
  19. K. Gaarder, Science 132, 471 (1960).
  20. J. Stuart and H. M. Burian, Am. J. Ophthalmol. 53, 471 (1962).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.