Temperature Variation of the Index of Refraction of ADP, KDP, and Deuterated KDP
JOSA, Vol. 56, Issue 5, pp. 629-632 (1966)
http://dx.doi.org/10.1364/JOSA.56.000629
Acrobat PDF (411 KB)
Abstract
The indices of refraction of ADP, KDP, and deuterated KDP were measured at temperatures between the Curie point and room temperature. The estimated accuracy of the data is ±0.0001. The empirical equation Δn= (n2+an+b)c(298-T) where n is the index at room temperature, Δn is the change in index, and T is the temperature in °K, fits the measurements to within experimental error. The values of the constants a, b, and c are tabulated for each material, permitting n to be calculated for any temperature.
Citation
RICHARD A. PHILLIPS, "Temperature Variation of the Index of Refraction of ADP, KDP, and Deuterated KDP," J. Opt. Soc. Am. 56, 629-632 (1966)