OSA's Digital Library

Journal of the Optical Society of America

Journal of the Optical Society of America

  • Vol. 68, Iss. 9 — Sep. 1, 1978
  • pp: 1181–1183

Comparison of synchrotron and laboratory discharge light sources

K. Radler and J. Berkowitz  »View Author Affiliations


JOSA, Vol. 68, Issue 9, pp. 1181-1183 (1978)
http://dx.doi.org/10.1364/JOSA.68.001181


View Full Text Article

Acrobat PDF (411 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A direct comparison has been made between the intensity of dispersed radiation from a laboratory Hopfield helium continuum and that obtained from the electron storage ring called Tantalus 1. The relative advantages and disadvantages of the respective light sources are described. Extrapolation of this information to other (present and future) electron storage-ring sources is discussed.

© 1978 Optical Society of America

Citation
K. Radler and J. Berkowitz, "Comparison of synchrotron and laboratory discharge light sources," J. Opt. Soc. Am. 68, 1181-1183 (1978)
http://www.opticsinfobase.org/josa/abstract.cfm?URI=josa-68-9-1181


Sort:  Author  |  Journal  |  Reset

References

  1. For normal incidence region see:D. Reinke, R. Kraessig, and H. Baumgartl, Z. Naturforsch. 28a, 1021 (1973); W. L. Stebbings and J. W. Taylor, Int. J. Mass Spectrom. Ion Phys. 9, 471 (1972); G. R. Parr and J. W. Taylor, Rev. Sci. Instrum. 44, 1578 (1973). For grazing incidence region, see: V. Schmidt, N. Sendner, H. Kuntzemuller, P. Dhez, F. Wuilleumier, and E. Kallne, Phys. Rev. A 13, 1748 (1976).
  2. J. Schwinger, Phys. Rev. 75, 1912 (1949).
  3. See, for example, R. P. Godwin, Springer Tracts Mod. Phys. 51, 1 (1969); K. Codling, Rep. Prog. Phys. 36, 541 (1973).
  4. W. Gudat (private communication).
  5. V. Saile, P. Gurtler, E. E. Koch, A. Kozevnikov, M. Skibowski, and W. Steinman, Appl. Opt. 15, 2559 (1976). Note: According to one of the above authors (V. Saile) Fig. 4 of their publication, showing the light intensity available at the exit slit of the monochromator at the DORIS synchrotron radiation facility is slightly misleading. The peak intensity they actually observed was 6 × 109 photons/s with 0.3 Å band pass (100 µm slits) but the intensity would only increase linearly when going to 300 µm slits because the image of the synchrotron source is only 100 µm wide at the entrance slit.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.