Abstract

The purpose of this work was to design ophthalmic lenses that correct peripheral refractive errors of human eyes along a meridian. We designed lenses with the tangential section of one surface based on a figured spheroid but figured in the tangential section only. The curvature of the sagittal section of this surface was adjusted separately. A merit function was used to modify these surfaces until the lenses had power errors that corrected the eye. Examples are presented of lenses that correct a schematic eye. They do excellent jobs of correcting the peripheral power errors of the eye and are relatively insensitive to small changes in fitting distance. We conclude that it is theoretically feasible to design lenses to correct peripheral refractive errors.

© 2002 Optical Society of America

OCIS Codes
(080.3620) Geometric optics : Lens system design
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices
(330.5370) Vision, color, and visual optics : Physiological optics

History
Original Manuscript: January 16, 2001
Manuscript Accepted: June 4, 2001
Published: January 1, 2002

Citation
George Smith, David A. Atchison, Chitralekha Avudainayagam, and Kodikullam Avudainayagam, "Designing lenses to correct peripheral refractive errors of the eye," J. Opt. Soc. Am. A 19, 10-18 (2002)
http://www.opticsinfobase.org/josaa/abstract.cfm?URI=josaa-19-1-10


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. D. A. Atchison, G. Smith, Optics of the Human Eye (Butterworth-Heinemann, Oxford, UK, 2000), 147–149.
  2. C. E. Ferree, G. Rand, C. Hardy, “Refraction for the peripheral field of vision,” Arch. Ophthalmol. 9, 925–938 (1931). [CrossRef]
  3. T. C. A. Jenkins, “Aberrations of the eye and their effects on vision: part 2,” Br. J. Physiol. Opt. 20, 161–201 (1963). [PubMed]
  4. F. Rempt, J. Hoogerheide, W. P. H. Hoogenbloom, “Peripheral retinoscopy and the skiagram,” Ophthalmologica 162, 1–10 (1971). [CrossRef] [PubMed]
  5. G. Smith, M. Millodot, N. McBrien, “The effect of accommodation on oblique astigmatism and field curvature of the human eye,” Clin. Exp. Optom. 71, 119–125 (1988). [CrossRef]
  6. D. G. Green, “Regional variations in the visual acuity for interference fringes at the retina,” J. Physiol. (London) 207, 351–356 (1970).
  7. M. Millodot, C. A. Johnson, A. Lamont, H. W. Leibowitz, “Effect of dioptrics on peripheral visual acuity,” Vision Res. 15, 1357–1362 (1975). [CrossRef] [PubMed]
  8. L. Frisen, A. Glansholm, “Optical and neural resolution in peripheral vision,” Invest. Ophthalmol. 14, 528–536 (1975). [PubMed]
  9. F. Rempt, J. Hoogerheide, W. P. H. Hoogenbloom, “Influence of correction of peripheral refractive errors on peripheral static vision,” Ophthalmologica 173, 128–135 (1976). [CrossRef] [PubMed]
  10. C. A. Johnson, H. W. Leibowitz, M. Millodot, A. Lamont, “Peripheral visual acuity and refractive error: evidence for ‘two visual systems’?” Percept. Psychophys. 20, 460–462 (1976). [CrossRef]
  11. L. N. Thibos, “Acuity perimetry and the sampling theory of visual resolution,” Optom. Vision Sci. 75, 399–406 (1998). [CrossRef]
  12. H. W. Leibowitz, C. A. Johnson, E. Isabelle, “Peripheral motion detection and refractive error,” Science 177, 1207–1208 (1972). [CrossRef] [PubMed]
  13. Y-Z. Wang, L. N. Thibos, A. Bradley, “Effects of refractive error on detection acuity and resolution acuity in peripheral vision,” Invest. Ophthalmol. Visual Sci. 38, 2134–2143 (1997).
  14. D. R. Williams, P. Artal, R. Navarro, M. J. McMahon, D. H. Brainard, “Off-axis optical quality and retinal sampling in the human eye,” Vision Res. 36, 1103–1114 (1996). [CrossRef] [PubMed]
  15. D. A. Atchison, “Effect of defocus on visual field measurement,” Ophthalmic Physiol. Opt. 7, 259–265 (1987). [CrossRef] [PubMed]
  16. F. Fankhauser, J. M. Enoch, “The effects of blur upon perimetric thresholds,” Arch. Ophthalmol. 68, 240–251 (1962). [CrossRef] [PubMed]
  17. S. M. Drance, C. Wheeler, M. Pattullo, “The use of static perimetry in the early detection of glaucoma,” Can. J. Ophthalmol. 2, 249–258 (1967). [PubMed]
  18. M. Jalie, Principles of Ophthalmic Lenses, 4th ed. (Association of Dispensing Opticians, London, 1984).
  19. D. A. Atchison, “Spectacle lens design: a review,” Appl. Opt. 31, 3579–3585 (1992). [CrossRef] [PubMed]
  20. G. Smith, D. A. Atchison, The Eye and Visual Optical Instruments (Cambridge U. Press, New York, 1997), p. 118.
  21. R. Navarro, J. Santamarı́a, J. Bescós, “Accommodation-dependent model of the human eye with aspherics,” J. Opt. Soc. Am. A 2, 1273–1281 (1985). [CrossRef] [PubMed]
  22. I. Escudero-Sanz, R. Navarro, “Off-axis aberrations of a wide-angle schematic eye model,” J. Opt. Soc. Am. A 16, 1881–1891 (1999). [CrossRef]
  23. L. N. Thibos, R. A. Applegate, J. T. Schwiegerling, R. Webb, and VSIA Standards Taskforce Members, “Report from the VSIA taskforce on standards for reporting optical aberrations of the eye,” J. Refract. Surg. 16, S654–S655 (2000). [PubMed]
  24. R. Noll, “Zernike aberrations and atmospheric turbulence,” J. Opt. Soc. Am. 66, 207–211 (1976). [CrossRef]
  25. R. Navarro, E. Moreno, C. Dorronsoro, “Monochromatic aberrations and point-spread functions of the human eye across the visual field,” J. Opt. Soc. Am. A 15, 2522–2529 (1998). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited