OSA's Digital Library

Journal of the Optical Society of America A

Journal of the Optical Society of America A

| OPTICS, IMAGE SCIENCE, AND VISION

  • Editor: Stephen A. Burns
  • Vol. 24, Iss. 5 — May. 1, 2007
  • pp: 1284–1295

Characterizing image quality in a scanning laser ophthalmoscope with differing pinholes and induced scattered light

Jennifer J. Hunter, Christopher J. Cookson, Marsha L. Kisilak, Juan M. Bueno, and Melanie C.W. Campbell  »View Author Affiliations


JOSA A, Vol. 24, Issue 5, pp. 1284-1295 (2007)
http://dx.doi.org/10.1364/JOSAA.24.001284


View Full Text Article

Enhanced HTML    Acrobat PDF (535 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We quantify the effects on scanning laser ophthalmoscope image quality of controlled amounts of scattered light, confocal pinhole diameter, and age. Optical volumes through the optic nerve head were recorded for a range of pinhole sizes in 12 subjects ( 19 64   years ) . The usefulness of various overall metrics in quantifying the changes in fundus image quality is assessed. For registered and averaged images, we calculated signal-to-noise ratio, entropy, and acutance. Entropy was best able to distinguish differing image quality. The optimum confocal pinhole diameter was found to be 50 μ m (on the retina), providing improved axial resolution and image quality under all conditions.

© 2007 Optical Society of America

OCIS Codes
(110.2960) Imaging systems : Image analysis
(110.3000) Imaging systems : Image quality assessment
(170.1790) Medical optics and biotechnology : Confocal microscopy
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(330.4300) Vision, color, and visual optics : Vision system - noninvasive assessment
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices

ToC Category:
Instrumentation and Techniques for Retinal Imaging

History
Original Manuscript: August 22, 2006
Revised Manuscript: November 2, 2006
Manuscript Accepted: November 6, 2006
Published: April 11, 2007

Virtual Issues
Vol. 2, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Jennifer J. Hunter, Christopher J. Cookson, Marsha L. Kisilak, Juan M. Bueno, and Melanie C. W. Campbell, "Characterizing image quality in a scanning laser ophthalmoscope with differing pinholes and induced scattered light," J. Opt. Soc. Am. A 24, 1284-1295 (2007)
http://www.opticsinfobase.org/josaa/abstract.cfm?URI=josaa-24-5-1284


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. Liang and D. R. Williams, "Aberrations and retinal image quality of the normal human eye," J. Opt. Soc. Am. A 14, 2873-2883 (1997). [CrossRef]
  2. L. N. Thibos, X. Hong, A. Bradley, and X. Cheng, "Statistical variation of aberration structure and image quality in a normal population of healthy eyes," J. Opt. Soc. Am. A 19, 2329-2348 (2002). [CrossRef]
  3. M. Shahidi, N. P. Blair, M. Mori, and R. Zelkha, "Optical section retinal imaging and wavefront sensing in diabetes," Optom. Vision Sci. 81, 778-784 (2004). [CrossRef]
  4. T. Kuroda, T. Fujikado, N. Maeda, T. Oshika, Y. Hirohara, and T. Mihashi, "Wavefront analysis in eyes with nuclear or cortical cataract," Am. J. Ophthalmol. 134, 1-9 (2002). [CrossRef] [PubMed]
  5. P. W. de Waard, J. K. Ijspeert, T. J. van den Berg, and P. T. de Jong, "Intraocular light scattering in age-related cataracts," Invest. Ophthalmol. Visual Sci. 33, 618-625 (1992).
  6. P. Artal, A. Guirao, E. Berrio, P. Piers, and S. Norrby, "Optical aberrations and the aging eye," Invest. Ophthalmol. Visual Sci. 43, 63-77 (2003).
  7. T. Kuroda, T. Fujikado, S. Ninomiya, N. Maeda, Y. Hirohara, and T. Mihashi, "Effect of aging on ocular light scatter and higher order aberrations," J. Refract. Surg. 18, S598-602 (2002). [PubMed]
  8. J. K. Ijspeert, P. W. de Waard, T. J. van den Berg, and P. T. de Jong, "The intraocular straylight function in 129 healthy volunteers: dependence on angle, age and pigmentation," Vision Res. 30, 699-707 (1990). [CrossRef] [PubMed]
  9. G. Westheimer and J. Liang, "Evaluating diffusion of light in the eye by objective means," Invest. Ophthalmol. Visual Sci. 35, 2652-2657 (1994).
  10. Y. Zhang, S. Poonja, and A. Roorda, "MEMS-based adaptive optics scanning laser ophthalmoscopy," Opt. Lett. 31, 1268-1270 (2006). [CrossRef] [PubMed]
  11. R. H. Webb, G. W. Hughes, and O. Pomerantzeff, "Flying spot TV ophthalmoscope," Appl. Opt. 19, 2991-2997 (1980). [CrossRef] [PubMed]
  12. C. Beckman, L. Bond-Taylor, B. Lindblom, and J. Sjostrand, "Confocal fundus imaging with a scanning laser ophthalmoscope in eyes with cataract," Br. J. Ophthamol. 79, 900-904 (1995). [CrossRef]
  13. L. Zangwill, I. Irak, C. Berry, and V. Garden, "Effect of cararact and pupil size on image quality with confocal scanning laser ophthalmoscopy," Arch. Ophthalmol. (Chicago) 115, 983-990 (1997).
  14. A. Plesch, U. Klingbeil, W. Rappl, and C. Schrodel, "Scanning ophthalmic imaging," in Scanning Laser Ophthalmoscopy and Tomography, J.E.Nasemann and R.O. W.Burk, eds. (Quintessenz, 1990), pp. 23-33.
  15. R. H. Webb and G. W. Hughes, "Scanning laser ophthalmoscope," IEEE Trans. Biomed. Eng. BME28, 488-492 (1981). [CrossRef]
  16. C. Beckman, M. Atkinson, M. Stargard, R. Munger, and M. Campbell, "The influence of increased interocular light scatter on the contrast in a confocal scanning laser ophthalmoscope image," in Vision Science and its Applications, Vol. 1 of 1995 OSA Technical Digest Series (Optical Society of America, 1995), pp. 55-69.
  17. M. A. Burke, C. J. Khanna, A. Miller, S. T. Venkataraman, and C. Hudson, "The impact of artificial light scatter on scanning laser tomography," Optom. Vision Sci. 83, 222-227 (2006). [CrossRef]
  18. A. J. Roorda, "Double pass reflections in the human eye," Ph.D. thesis (University of Waterloo, Canada, 1996).
  19. M. J. Booth, M. A. A. Neil, and T. Wilson, "Aberration correction for confocal imaging in refractive-index-mismatched media," J. Microsc. 192, 90-98 (1998). [CrossRef]
  20. W. J. Donnelly III and A. Roorda, "Optimal pupil size in the human eye for axial resolution," J. Opt. Soc. Am. A 20, 2010-2015 (2003). [CrossRef]
  21. A. Manivannan, P. F. Sharp, and J. V. Forrester, "Performance-measurements of an infrared digital scanning laser ophthalmoscope," Physiol. Meas. 15, 317-324 (1994). [CrossRef]
  22. T. Wilson, "The role of the pinhole in confocal imaging system," in Handbook of Biological Confocal Microscopy, J.B.Pawley, ed. (Plenum, 1995), pp. 167-182.
  23. M. J. Booth, M. A. A. Neil, R. Juskaitis, and T. Wilson, "Adaptive aberration correction in a confocal microscope," Proc. Natl. Acad. Sci. U.S.A. 99, 5788-5792 (2002). [CrossRef] [PubMed]
  24. J. M. Bueno and M. C. W. Campbell, "Confocal scanning laser ophthalmoscopy improvement by use of Mueller-matrix polarimetry," Opt. Lett. 27, 830-832 (2002). [CrossRef]
  25. K. Muth, M. C. W. Campbell, A. J. Roorda, and C. Cui, "The effect of entrance beam location on image quality of CSLO images," in Vision Science and Its Applications, Vol. 1 of 1997 OSA Technical Digest Series(Optical Society of America, 1997), pp. 56-59.
  26. K. M. Muth, "The effect of entrance beam diameter and position within the pupil on the image quality of a confocal scanning laser ophthalmoscope," MSc thesis (University of Waterloo, Canada, 1998).
  27. J. M. Bueno and B. Vohnsen, "Polarimetric high-resolution confocal scanning laser ophthalmoscope," Vision Res. 45, 3526-3534 (2005). [CrossRef] [PubMed]
  28. S. A. Burns, A. E. Elsner, M. B. Mellem-Kairala, and R. B. Simmons, "Improved contrast of subretinal structures using polarization analysis," Invest. Ophthalmol. Visual Sci. 44, 4061-4068 (2003). [CrossRef]
  29. Y. F. Choong, F. Rakebrandt, R. V. North, and J. E. Morgan, "Acutance, an objective measure of retinal nerve fibre image clarity," Br. J. Ophthamol. 87, 322-326 (2003). [CrossRef]
  30. S. J. Cox, V. Y. Reshetnyak, and T. J. Sluckin, "Theory of dielectric and optical properties of PDLC films," Mol. Cryst. Liq. Cryst. 320, 301-320 (1998). [CrossRef]
  31. M. Ozolinsh and G. Papelba, "Eye cataract simulation using polymer dispersed liquid crystal scattering obstacles," Ferroelectrics 304, 1037-1042/207-212 (2004). [CrossRef]
  32. J. M. Bueno, E. Berrio, M. Ozolinsh, and G. Ikaunieks, "Optical properties of a polymer dispersed liquid crystal to be used on visual testing," in Proceedings of ICO Topical Meeting on Optoinformatics/Information Photonics (ICO, 2006), pp. 276-278.
  33. American National Standards Institute, "American National Standard for safe use of lasers," Z136.1-2000 (Laser Institute of America, 2000).
  34. J.W. Goodman, "Statistical properties of laser speckle patterns," in Topics in Applied Physics: Laser Speckle and Related Phenomena, J.C.Dainty, ed. (Springer-Verlag, 1975), Vol. 9, pp. 9-75. [CrossRef]
  35. R. C. Gonzalez, R. E. Woods, and S. L. Eddins, Digital Image Processing Using MATLAB (Pearson Prentice Hall, 2004), p. 609. [PubMed]
  36. R. M. Rangayyan, N. M. El-Faramawy, J. E. Desautels, and O. A. Alim, "Measures of acutance and shape for classification of breast tumors," IEEE Trans. Med. Imaging 16, 799-810 (1997). [CrossRef]
  37. D. C. Howell, Statistical Methods for Psychology (Duxbury/Thomson Learning, 2002).
  38. K. R. Castleman, Digital Image Processing (Prentice Hall, 1996).
  39. T. Wilson and A. R. Carlini, "Size of the detector in confocal imaging systems," Opt. Lett. 12, 227-229 (1987). [CrossRef] [PubMed]
  40. F. W. Campbell and R. W. Gubisch, "Optical quality of the human eye," J. Physiol. (London) 186, 558-578 (1966).
  41. J. Liang and G. Westheimer, "Optical performances of human eyes derived from double-pass measurements," J. Opt. Soc. Am. A 12, 1411-1416 (1995). [CrossRef]
  42. P. Artal and R. Navarro, "Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expression," J. Opt. Soc. Am. A 11, 246-249 (1994). [CrossRef]
  43. P. Artal, M. Ferro, I. Miranda, and R. Navarro, "Effects of aging in retinal image quality," J. Opt. Soc. Am. A 10, 1656-1662 (1993). [CrossRef] [PubMed]
  44. K. Venkateswaran, A. Roorda, and F. Romero-Borja, "Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope," J. Biomed. Opt. 9, 132-138 (2004). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited