Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of the Optical Society of Korea
  • Vol. 16,
  • Issue 4,
  • pp. 418-424
  • (2012)

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

Open Access Open Access

Abstract

The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

© 2012 Optical Society of Korea

PDF Article
More Like This
Cambridge Colour Test: reproducibility in normal trichromats

T. P. Fernandes, N. A. Santos, and G. V. Paramei
J. Opt. Soc. Am. A 37(4) A70-A80 (2020)

Test-retest reliability of fNIRS in resting-state cortical activity and brain network assessment in stroke patients

Gongcheng Xu, Congcong Huo, Jiahui Yin, Yanbiao Zhong, Guoyu Sun, Yubo Fan, Daifa Wang, and Zengyong Li
Biomed. Opt. Express 14(8) 4217-4236 (2023)

TuebingenCSTest – a useful method to assess the contrast sensitivity function

Tim Schilling, Arne Ohlendorf, Alexander Leube, and Siegfried Wahl
Biomed. Opt. Express 8(3) 1477-1487 (2017)

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.