Abstract

In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.

© 2012 Optical Society of Korea

PDF Article
More Like This
Optical aberrations of intraocular lenses measured in vivo and in vitro

Sergio Barbero, Susana Marcos, and Ignacio Jiménez-Alfaro
J. Opt. Soc. Am. A 20(10) 1841-1851 (2003)

Impact of environmental temperature on optical power properties of intraocular lenses

Bennett N. Walker, Robert H. James, Don Calogero, and Ilko K. Ilev
Appl. Opt. 53(3) 453-457 (2014)

Subjective evaluation of intraocular lenses by visual acuity measurement using adaptive optics

Huanqing Guo, Hamid R. Fallah, Chris Dainty, and Alexander V. Goncharov
Opt. Lett. 37(12) 2226-2228 (2012)

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved