Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation
Journal of the Optical Society of Korea, Vol. 16, Issue 4, pp. 418-424 (2012)
Acrobat PDF (542 KB)
Abstract
The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.
© 2012 Optical Society of Korea
OCIS Codes
(170.1610) Medical optics and biotechnology : Clinical applications
(170.4460) Medical optics and biotechnology : Ophthalmic optics and devices
(330.1400) Vision, color, and visual optics : Vision - binocular and stereopsis
History
Original Manuscript: September 6, 2012
Revised Manuscript: November 5, 2012
Manuscript Accepted: November 5, 2012
Published: December 25, 2012
Citation
Byeong-Yeon Moon, Sun-Young Park, and Hyun Gug Cho, "Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation," J. Opt. Soc. Korea 16, 418-424 (2012)
http://www.opticsinfobase.org/josk/abstract.cfm?URI=josk-16-4-418
Cited By |
OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.





OSA is a member of 