OSA's Digital Library

Optics Express

Optics Express

  • Editor: Michael Duncan
  • Vol. 12, Iss. 13 — Jun. 28, 2004
  • pp: 2977–2998

Motion artifacts in optical coherence tomography with frequency-domain ranging

S. H. Yun, G. J. Tearney, J. F. de Boer, and B. E. Bouma  »View Author Affiliations


Optics Express, Vol. 12, Issue 13, pp. 2977-2998 (2004)
http://dx.doi.org/10.1364/OPEX.12.002977


View Full Text Article

Enhanced HTML    Acrobat PDF (672 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We describe results of theoretical and experimental investigations of artifacts that can arise in spectral-domain optical coherence tomography (SD-OCT) and optical frequency domain imaging (OFDI) as a result of sample or probe beam motion. While SD-OCT and OFDI are based on similar spectral interferometric principles, the specifics of motion effects are quite different because of distinct signal acquisition methods. These results provide an understanding of motion artifacts such as signal fading, spatial distortion and blurring, and emphasize the need for fast image acquisition in biomedical applications.

© 2004 Optical Society of America

OCIS Codes
(110.4500) Imaging systems : Optical coherence tomography
(170.0110) Medical optics and biotechnology : Imaging systems
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(170.4500) Medical optics and biotechnology : Optical coherence tomography

ToC Category:
Research Papers

History
Original Manuscript: March 5, 2004
Revised Manuscript: June 17, 2004
Published: June 28, 2004

Citation
S. H. Yun, G. Tearney, J. de Boer, and B. Bouma, "Motion artifacts in optical coherence tomography with frequency-domain ranging," Opt. Express 12, 2977-2998 (2004)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-12-13-2977


Sort:  Journal  |  Reset  

References

  1. N. Bankman, Handbook of medical imaging (Academic Press, San Diego, 2000).
  2. R. J. Alfidi, W. J. MacIntyre, and . R. Haaga, ???The effects of biological motion in CT resolution,??? Am. J. Radiol. 127, 11-15 (1976).
  3. M. L. Wood and R. M. Henkelman, ???NMR image artifact from periodic motion,??? Med. Phys. 12, 143-151 (1985). [CrossRef] [PubMed]
  4. S. K. Nadkarni, D. R. Boughner, M. Drangova, and A. Fenster, ???In vitro simulation and quantification of temporal jitter artifacts in ECG-gated dynamic three-dimensional echocardiography,??? Ultrasound in Med. & Biol. 27, 211-222 (2001). [CrossRef]
  5. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, ???Optical coherence tomography,??? Science 254, 1178-1181 (1991). [CrossRef] [PubMed]
  6. J. G. Fujimoto, M. E. Brezinski, G. J. Tearney, S. A. Boppart, B. Bouma, M. R. Hee, J. F. Southern, and E. A. Swanson, ???Optical biopsy and imaging using optical coherence tomography,??? Nat. Medicine 1, 970-972 (1995). [CrossRef]
  7. R. C. Youngquist, S. Carr, and D. E. N. Davies, ???Optical coherence-domain reflectometry: A new optical evaluation technique,??? Opt. Lett., 12, 158-160 (1987). [CrossRef] [PubMed]
  8. A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, ???Measurements of intraocular distances by backscattering spectral interferometry,??? Opt. Comm. 117, 43-48 (1995). [CrossRef]
  9. G. Hausler and M. W. Lindner, ???Coherence radar and spectral radar - new tools for dermatological diagnosis,??? J. Biomed. Opt. 3, 21-31 (1998). [CrossRef]
  10. M. Wojtkowski, T. Bajraszewski, P. Targowski, and A. Kowalczyk, ???Real time in vivo imaging by high-speed spectral optical coherence tomography,??? Opt. Lett. 28, 1745-1747 (2003). [CrossRef] [PubMed]
  11. S. H. Yun, G. J. Tearney, B. E. Bouma, B. H. Park, and J. F. de Boer, ???High-speed spectral domain optical coherence tomography at 1.3 µm wavelength,??? Opt. Express 11, 3598-3604 (2003), <a href=" http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-26-3598">http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-26-3598</a> [CrossRef] [PubMed]
  12. N. Nassif, B Cense, B. H. Park, S. H. Yun, G. J. Tearney, B. E. Bouma, T. C. Chen, and J. F. de Boer, ???In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve,??? Opt. Express 12, 367-376 (2004), <a href=" http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-3-367">http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-3-367</a> [CrossRef] [PubMed]
  13. F. Lexer, C. K. Hitzenberger, A. F. Fercher, and M. Kulhavy, ???Wavelength-tuning interferometry of intraocular distances,??? Appl. Opt. 36, 6548-6553 (1997). [CrossRef]
  14. S. R. Chinn, E. Swanson, and J. G. Fujimoto, ???Optical coherence tomography using a frequency-tunable optical source,??? Opt. Lett. 22, 340-342 (1997). [CrossRef] [PubMed]
  15. B. Golubovic, B. E. Bouma, G. J. Tearney, and J. G. Fujimoto, ???Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser,??? Opt. Lett. 22, 1704-1706 (1997). [CrossRef]
  16. S. H. Yun, G. J. Tearney, J. F. de Boer, N. Iftimia, and B. E. Bouma, ???High-speed optical frequency-domain imaging,??? Opt. Express 11, 2953-2963 (2003), <a href="http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-22-2953">http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-22-2953</a> [CrossRef] [PubMed]
  17. T. Mitsui, ???Dynamic range of optical reflectometry with spectral interferometry,??? Jap. J. of App. Phys. 38, 6133-6137 (1999). [CrossRef]
  18. R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, ???Performance of Fourier domain vs. time domain optical coherence tomography,??? Opt. Express 11, 889-894 (2003), <a href="http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-8-889">http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-8-889</a> [CrossRef] [PubMed]
  19. J. F. de Boer, B. Cense, B.H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, ???Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography,??? Opt. Lett. 28, 2067-2069 (2003). [CrossRef] [PubMed]
  20. M. A. Choma, M. V. Sarunic, C. Uang, and J. A. Izatt, ???Sensitivity advantage of swept source and Fourier domain optical coherence tomography,??? Opt. Express 11, 2183-2189 (2003), <a href="http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-18-2183">http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-18-2183</a> [CrossRef] [PubMed]
  21. N. Nassif, B. Cense, B. H. Park, S. H. Yun, T. C. Chen, B. E. Bouma, G. J. Tearney, and J. F. de Boer, ???In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography,??? Opt. Lett. 29, 480-482 (2004). [CrossRef] [PubMed]
  22. W. Eickhoff and R. Ulrich, ???Optical frequency domain reflectometry in single-mode fiber,??? App. Phy. Lett. 39, 693-695 (1981). [CrossRef]
  23. E. Brinkmeyer and R. Ulrich, ???High-resolution OCDR in dispersive waveguide,??? Electron. Lett. 26, 413-414 (1990). [CrossRef]
  24. J. M. Schmitt and A. Knuttel, ???Model of optical coherence tomography of heterogeneous tissue,??? J. Opt. Soc. Am. A 14, 1231-1242 (1997). [CrossRef]
  25. E. A. Swanson, D. Huang, M. R. Hee, J. G. Fujimoto, C. P. Lin, and C. A. Puliafito, ???High-speed optical coherence domain reflectometry,??? Opt. Lett. 17, 151-153 (1992). [CrossRef] [PubMed]
  26. J. M. Schmitt, S. H. Xiang, and K. M. Yung, ???Speckle in optical coherence tomography,??? J. Biomed. Opt. 4, 95-105 (1999). [CrossRef] [PubMed]
  27. S.-M. Stengel, Y. Allemann, M. Zimmerli, E. Lipp, N. Kucher, P. Mohacsi, and C. Seiler, ???Doppler tissue imaging for assessing left ventricular diastolic dysfunction in heart transplant rejection,??? Heart 86, 432-437 (2001). [CrossRef] [PubMed]
  28. M. V. Sivak Jr., K. Kobayashi, J. A. Izatt, A. M. Rollins, R. Ung-runyawee, A. Chak, R. C. K. Wong, G. A. Isenbert, and J. Willis, ???High-resolution Endoscopic imaging of the GI tract using optical coherence tomography,??? Gastrointest. Endosc. 51, 474-479 (2000). [CrossRef] [PubMed]
  29. G. J. Tearney, H. Yabushita, S. L. Houser, H. T. Aretz, I. K. Jang, K. Schlendorf, C. R. Kauffman, M. Shishkov, E. F. Halpern, and B. E. Bouma, ???Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography,??? Circulation 106, 113-119 (2003) [CrossRef]
  30. G. J. Tearney, S. A. Boppart, B. E. Bouma, M. E. Brezinski, N. J. Weissman, J. F. Southern, and J. G. Fujimoto, ???Scanning single-mode fiber optic catheter-endoscope for optical coherence tomography," Opt. Lett. 21, 1-3 (1996).
  31. A. E. Siegman, Lasers (University Science Books, Mill Valley, 1986), Chap. 9.
  32. S. H. Yun, C. Boudoux, G. J. Tearney, and B. E. Bouma, ???High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter,??? Opt. Lett. 28, 1981-1983 (2003). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited