An attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging

Aimin Yan, Xizeng Wu, and Hong Liu  »View Author Affiliations


Optics Express, Vol. 16, Issue 17, pp. 13330-13341 (2008)
http://dx.doi.org/10.1364/OE.16.013330


View Full Text Article

Enhanced HTML    Acrobat PDF (731 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

For medical applications of the in-line phase-contrast x-ray imaging, phase retrieval is a crucial step for quantitative imaging such as reconstructing the 3-D distribution of tissue linear attenuation coefficients and refraction indices. The conventional phase retrieval algorithms, such as the transport of intensity equation (TIE) based algorithms, are not robust against the quantum noise that appears in acquired images due to the radiation dose constraints in medical imaging. In this work a new attenuation-partition based iterative phase retrieval algorithm is proposed. This new algorithm takes advantage of the correlation between the attenuation and phase-shift, and is much robust against noise in acquired images. Phase retrieval results from experimental images show that this new iterative algorithm is fast and robust, and it has good potential for medical x-ray imaging applications.

© 2008 Optical Society of America

OCIS Codes
(030.1670) Coherence and statistical optics : Coherent optical effects
(340.7440) X-ray optics : X-ray imaging

ToC Category:
X-ray Optics

History
Original Manuscript: June 2, 2008
Revised Manuscript: July 31, 2008
Manuscript Accepted: August 5, 2008
Published: August 14, 2008

Virtual Issues
Vol. 3, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Aimin Yan, Xizeng Wu, and Hong Liu, "An attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging," Opt. Express 16, 13330-13341 (2008)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-17-13330


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. Snigirev, I. Snigireva, V. Kohn, S. Kuznetsov, and I. Shelokov, "On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation," Rev. Sci. Instrum. 66, 5486 - 5492 (1995). [CrossRef]
  2. S. Wilkins, T. Gureyev, D. Gao, A. Pogany, and A. Stevenson, "Phase-contrast imaging using polychromatic hard X-rays," Nature 384, 335 - 338 (1996). [CrossRef]
  3. A. Pogany, D. Gao, and S. Wilkins, "Contrast and resolution in imaging with a microfocus x-ray source," Rev. Sci. Instrum. 68, 2774 (1997). [CrossRef]
  4. D. Paganin and K. Nugent, "Noninterferometric Phase Imaging with Partially Coherent Light," Phy. Rev. Lett. 80, 2586 - 2589 (1998). [CrossRef]
  5. X. Wu and H. Liu, "A general theoretical formalism for X-ray phase contrast imaging," J. X-ray Sci. Technol. 11, 33 - 42 (2003).
  6. X.  Wu and H. Liu, "Clinical implementation of x-ray phase-contrast imaging: Theoretical foundations and design considerations," Med. Phys. 30, 2169 - 2179 (2003). [CrossRef] [PubMed]
  7. E. Donnelly, R. Price, and D. Pickens, "Dual focal-spot imaging for phase extraction in phase-contrast radiography," Med. Phys. 30, 2292 - 2296 (2003). [CrossRef] [PubMed]
  8. X. Wu and H. Liu, "A dual detector approach for X-ray attenuation and phase imaging," J. X-ray Sci. Technol. 12, 35-42 (2004).
  9. X. Wu and H. Liu, "An experimental method of determining relative phase-contrast factor for x-ray imaging systems," Med. Phys. 31, 997 - 1002 (2004). [CrossRef]
  10. X. Wu and H. Liu, "A new theory of phase-contrast x-ray imaging based on Wigner distributions," Med. Phys. 31, 2378 - 2384 (2004). [CrossRef] [PubMed]
  11. X. Wu and H. Liu, "A reconstruction formula for soft tissue X-ray phase tomography," J. X-ray Sci. Technol. 12, 273 - 279 (2004).
  12. X. Wu, H. Liu, and A. Yan, "X-ray phase-attenuation duality and phase retrieval," Opt. Lett. 30(4), 379 - 381 (2005). [CrossRef] [PubMed]
  13. X. Wu, H. Liu, and A. Yan, "Phase-Contrast X-Ray Tomography: Contrast Mechanism and Roles of Phase Retrieval," Eur. J. Radiol. (to be published) (2008). [CrossRef] [PubMed]
  14. A. Bronnikov, "Theory of quantitative phase-contrast computed tomography," J. Opt. Soc. Am. A 19, 472 - 480 (2002). [CrossRef]
  15. X. Wu and H. Liu, "X-Ray cone-beam phase tomography formulas based on phase-attenuation duality," Opt. Express 13, 6000 - 6014 (2005). [CrossRef] [PubMed]
  16. T. Gureyev, D. Paganin, G. Myers, Y. Nesterets, and S. Wilkins, "Phase-and-amplitude computer tomography," Appl. Phys. Lett. 89, 034,102 (2006). [CrossRef]
  17. R. M. P. Cloetens, M. Schlenker, and S. Lerbs-Mache, "Quantitative phase tomography of Arabidopsis seeds reveals intercellular void network," PNAS 103, 14,626 - 14,630 (2006). [CrossRef]
  18. K. Nugent, T. Gureyev, D. Cookson, D. Paganin, and Z. Barnea, "Quantitative Phase Imaging Using Hard X Rays," Phy. Rev. Lett. 77, 2961 - 2964 (1996). [CrossRef]
  19. L. Allen and M. Oxley, "Phase retrieval from series of images obtainedbe defocus variation," Opt. Commun. 199, 65 - 75 (2001). [CrossRef]
  20. X. Wu and H. Liu, "Phase-space evolution of x-ray coherence in phase-sensitive imaging," Appl. Opt. 47, E44 - E52 (2008). [CrossRef] [PubMed]
  21. M. Teague, "Deterministic phase retrieval: a Green�??s function solution," J. Opt. Soc. Am. 73, 1434 - 1441 (1983). [CrossRef]
  22. X. Wu and H. Liu, "Robustness of a phase-retrieval approach based on phase-attenuation duality," J. X-Ray Sci. Technol. 15, 85 - 95 (2007).
  23. A. Tikhonov and V. Arsenin, Solution of Ill-Posed Problems (Winston & Sons, Washington, 1977).
  24. I. Schelokov, T. Weitkamp, and A. Snigirev, "Reconstruction of an object phase transmission function from inline X-ray holograms," Opt. Commun. 213, 247 - 258 (2002). [CrossRef]
  25. T. Gureyev, A. Pogany, D. Paganin, and S. Wilkins, "Linear algorithms for phase retrieval in the Fresnel region," Opt. Commun. 231, 53 - 70 (2004). [CrossRef]
  26. N. Dyson, X-Rays in Atomic and Nuclear Physics (Longman Scientific and Technical, Essex, UK, 1973).
  27. X. Wu, A. Dean, and H. Liu, Biomedical Photonics Handbook, (CRC Press, Tampa, Fla., 2003), Chap. 26, pp. 26-1 - 26-34
  28. L. Hörmander, The Analysis of Linear Partial Differential Operators I (Springer, New York, 1983). [CrossRef]
  29. D. Zhang, M. Donvan, L. Fajardo, A. Archet, X. Wu, and H. Liu, "Preliminary feasibility study of an in-line phase contrast x-ray imaging prototype," IEEE Trans. Biomed. Eng. 55, (in press) (2008).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited