OSA's Digital Library

Optics Express

Optics Express

  • Editor: Michael Duncan
  • Vol. 13, Iss. 9 — May. 2, 2005
  • pp: 3376–3387

Novel detection of aerosols: combined cavity ring-down and fluorescence spectroscopy

Bruce A. Richman, Alexander A. Kachanov, Barbara A. Paldus, and Anthony W. Strawa  »View Author Affiliations


Optics Express, Vol. 13, Issue 9, pp. 3376-3387 (2005)
http://dx.doi.org/10.1364/OPEX.13.003376


View Full Text Article

Enhanced HTML    Acrobat PDF (270 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

High fluences inside cavity ring-down spectroscopy optical resonators lend themselves to fluorescence or nonlinear optical spectroscopy. An instrument at 488 nm was developed to measure extinction, and fluorescence of aerosols. A detection limit of 6×10-9 cm- 1Hz-1/2 (0.6 Mm-1Hz-1/2) was achieved. The fluorescence spectral power collected from a single fluorescent microsphere was 10 to 20 pW/nm. This power is sufficient to obtain the spectrum of a single microsphere with a resolution of 10 nm and signal-to-noise ratio of ~10. The relative concentrations of two types of fluorescent microspheres were determined from a time-integrated fluorescence measurement of a mixture of both.

© 2005 Optical Society of America

OCIS Codes
(300.2530) Spectroscopy : Fluorescence, laser-induced
(300.6360) Spectroscopy : Spectroscopy, laser

ToC Category:
Research Papers

History
Original Manuscript: March 17, 2005
Revised Manuscript: April 15, 2005
Published: May 2, 2005

Citation
Bruce Richman, Alexander Kachanov, Barbara Paldus, and Anthony Strawa, "Novel detection of aerosols: combined cavity ring-down and fluorescence spectroscopy," Opt. Express 13, 3376-3387 (2005)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-13-9-3376


Sort:  Journal  |  Reset  

References

  1. Y. Pan, S. Holler, et al., �??Single-shot fluorescence spectra of individual micrometer-sized bioaerosols illuminated by a 351- or a 266-nm ultraviolet laser,�?? Opt. Lett. 24, 116-118 (1999). [CrossRef]
  2. Y.-L. Pan, J. Hartings, R. G. Pinnick, S. C. Hill, J. Halverson, and R. K. Chang, �??Single-Particle Fluorescence Spectrometer for Ambient Aerosols,�?? Aer. Science and Tech. 37, 627-638 (2003).
  3. F. L. Reyes, T. H. Jeys, et al., �??Bio-aerosol fluorescence sensor,�?? Field Anal. Chem. and Tech. 3, 240-248 (1999). [CrossRef]
  4. Y.-L. Pan, V. Boutou, R. K. Chang, I. Ozden, K. Davitt, and A. V. Nurmikko, �??Application of light-emitting diodes for aerosol fluorescence detection,�?? Optics Letters 28, 1707-1709 (2003). [CrossRef] [PubMed]
  5. J. J. L. Spaanjaars, J. J. t. Meulen, and G. Meijer, �??Relative predissociation rates of OH (A 2Σ+, v'=3) from combined cavity ring down�??Laser-induced fluorescence measurements,�?? Journal of Chemical Physics 107, 2242-2248 (1997). [CrossRef]
  6. J. Luque, J. B. Jeffries, G. P. Smith, D. R. Crosley, and J. J. Scherer, �??Combined cavity ringdown absorption and laser-induced fluorescence imaging measurements of CN(B-X) and CH(B-X) in lowpressure CH4-O2-N2 and CH4-NO-O2-N2 flames,�?? Combustion and Flame 126, 1725-1735 (2001). [CrossRef]
  7. A. W. Strawa, R. Casteneda, et al., �??The Measurements of Aerosol Optical Properties using Continuous Wave Cavity Ring-down Techniques,�?? J. Atmos. And Ocean Tech. 20, 454-465 (2003). [CrossRef]
  8. A. D. Sappey, E. S. Hill, et al. �??Fixed-frequency cavity ringdown diagnostic for atmospheric particulate matter,�?? Opt. Lett. 23, 954-956 (1998). [CrossRef]
  9. R. L. VanderWal and T. M. Ticich, �??Cavity ringdown and laser-induced incandescence measurements of soot,�?? Appl. Opt. 38, 1444-1451 (1999). [CrossRef]
  10. D. Smith and D. B. Atkinson, �??A portable pulsed cavity ring-down transmissometer for measurement of the optical extinction of the atmospheric aerosol,�?? Analyst 126, 1216-1220 (2001). [CrossRef] [PubMed]
  11. V. Bulatov, M. Fisher, and I. Schechter, �??Aerosol Analysis by cavity-ring-down spectroscopy,�?? Anal. Chim. Acta 466, 1-9 (2002). [CrossRef]
  12. Pettersson, A., E. R. Lovejoy, et al. "Measurement of aerosol optical extinction at 532 nm with pulsed cavity ring-down spectroscopy,�?? J. Aerosol Sci. 35, 995-1011(2004). [CrossRef]
  13. H. Mossmuller, R. Varma, et al.. "Cavity Ring-down and Cavity-Enhanced Detection Techniques for the Measurement for Aerosol Extinction,�?? Aerosol Sci. Tech. 39, 30-39(2005 [CrossRef]
  14. B. A. Paldus, R. Provencal, and A. Kachanov, �??Cavity Enhanced Optical Detector,�?? U.S. Patent Application 10/738,599 (2004).
  15. K. W. Busch and M. A. Busch (Eds.), �??Cavity ring-down spectroscopy: An ultratrace absorption measurement technique,�?? ACS Symp. Ser 720 (1999). [CrossRef]
  16. J. Morville, D. Romanini, M. Chenevier, and A. Kachanov, �??Effects of laser phase noise on the injection of a high-finesse cavity�??, Appl. Opt. 41, 6980-6990 (2002). [CrossRef] [PubMed]
  17. K. L. Bechtel, R. N. Zare, et al., �??Moving Beyond Traditional UV-Vis Absorption Detection: Cavity Ring-Down Spectroscopy for HPLC,�?? Anal. Chem. 77, 1177-1182 (2005). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited