Time resolved fluorescence tomography of turbid media based on lifetime contrast

Anand T. N. Kumar, Scott B. Raymond, Gregory Boverman, David A. Boas, and Brian J. Bacskai  »View Author Affiliations


Optics Express, Vol. 14, Issue 25, pp. 12255-12270 (2006)
http://dx.doi.org/10.1364/OE.14.012255


View Full Text Article

Enhanced HTML    Acrobat PDF (346 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A general linear model for time domain (TD) fluorescence tomography is presented that allows a lifetime-based analysis of the entire temporal fluorescence response from a turbid medium. Simulations are used to show that TD fluorescence tomography is optimally performed using two complementary approaches: A direct TD analysis of a few time points near the peak of the temporal response, which provides superior resolution; and an asymptotic multi-exponential analysis based tomography of the decay portion of the temporal response, which provides accurate localization of yield distributions for various lifetime components present in the imaging medium. These results indicate the potential of TD technology for biomedical imaging with lifetime sensitive targeted probes, and provide useful guidelines for an optimal approach to fluorescence tomography with TD data.

© 2006 Optical Society of America

OCIS Codes
(170.3650) Medical optics and biotechnology : Lifetime-based sensing
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(170.6920) Medical optics and biotechnology : Time-resolved imaging
(170.7050) Medical optics and biotechnology : Turbid media

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: October 6, 2006
Revised Manuscript: November 27, 2006
Manuscript Accepted: November 29, 2006
Published: December 11, 2006

Virtual Issues
Vol. 2, Iss. 1 Virtual Journal for Biomedical Optics

Citation
Anand T. Kumar, Scott B. Raymond, Gregory Boverman, David A. Boas, and Brian J. Bacskai, "Time resolved fluorescence tomography of turbid media based on lifetime contrast," Opt. Express 14, 12255-12270 (2006)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-25-12255


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. Hintersteiner et al., "In-vivo detection of amyloid-beta deposits by near-infrared imaging using an oxazinederivative probe," Nat. Biotechnol. 23, 577 (2005). [CrossRef] [PubMed]
  2. V. Ntziachristos, J. Ripoll, L. V. Wang, R. Weissleder, "Looking and listening to light," Nat. Biotechnol. 23, 314 (2005).
  3. E. E. Graves, J. Ripoll, R. Weissleder, and V. Ntziachristos, "A submillimeter resolution for small animal imaging," Med. Phys. 30, 901 (2003). [CrossRef] [PubMed]
  4. M. A. Oleary, D. A. Boas, X.D. Li, B. Chance, and A. G. Yodh, "Fluorescence lifetime imaging in turbid media," Opt. Lett. 21, 158 (1996). [CrossRef]
  5. A. Godavarty, E. M. Sevick-Muraca and M. J. Eppstein, "Three-dimensional fluorescence lifetime tomography," Med. Phys. 48, 1701-1720 (2003). [CrossRef]
  6. B. B. Das, F. Liu and R. R. Alfano, "Time-resolved fluorescence and photon migration studies in biomedical and model random media," Rep. Prog. Phys. 60, 227 (1997). [CrossRef]
  7. K. Chen, L. T. Perelman, Q. G. Zhang, R. R. Dasari, and M. S. Feld, "Optical computed tomography in a turbid medium using early arriving photons," J. Biomed. Opt. 5144 (2000). [CrossRef] [PubMed]
  8. J. Wu, L. Perelman, R. R. Dasari, ans M. S. Feld, "Fluorescence tomographic imaging in turbid media using early-arriving photons and Laplace transforms," Proc. Natl. Acad. Sci. USA 94, 8783 (1997). [CrossRef] [PubMed]
  9. D. Hall, G. Ma, F. Lesage, Y. Wang, "Simple time-domain optical method for estimating the depth and concentration of a fluorescent inclusion in a turbid medium," Opt. Lett. 29, 2258 (2004). [CrossRef] [PubMed]
  10. G. M. Turner, G Zacharakis, A. Sourbet, J. Ripoll, V. Ntziachristos, "Complete-angle projection diffuse optical tomography by use of early photons," Opt. Lett. 30, 409 (2005). [CrossRef] [PubMed]
  11. G. Ma, N. Mincu, F. Lesage, P. Gallant, and L. McIntosh, "System irf impact on fluorescence lifetime fitting in turbid medium," Proc. SPIE 5699, 263 (2005). [CrossRef]
  12. S. Bloch, F. Lesage, L. Mackintosh, A. Gandjbakche, K. Liang, S Achilefu, "Whole-body fluorescence lifetime imaging of a tumor-targeted near-infrared molecular probe in mice," J. Biomed. Opt. 10, 054003-1 (2005). [CrossRef]
  13. A. T. N. Kumar, J. Skoch, B. J. Bacskai, D. A. Boas and A. K. Dunn, "Fluorescence lifetime-based tomography for turbid media," Opt. Lett. 30, 3347-3349 (2005). [CrossRef]
  14. D. Hattery, V. Chernomordik, M. Loew, I. Gannot, A. Gandjbakhche, J. Opt. Soc. Am. A, "Analytical solutions for time-resolved fluorescence lifetime imaging in a turbid medium such as tissue," J. Opt. Soc. Am. 18, 1523- 1530 (2001). [CrossRef]
  15. X. Lam, F. Lesage, X. Intes, "Time domain fluorescent diffuse optical tomography:analytical expressions," Opt. Express 13, 2263-2275 (2005). [CrossRef] [PubMed]
  16. S. V. Apreleva, D. F. Wilson, and S. A. Vinogradov, "Feasibility of diffuse optical imaging with long-lived luminescent probes," Opt. Lett. 31, 1082-1084 (2006) [CrossRef] [PubMed]
  17. P. R. Sevin, "The renaissance of fluorescence resonance energy transfer," Nat. Struct. Biol. 7, 730-734, (2000). [CrossRef]
  18. P. I. H. Bastiaens, and A. Squire, "Fluorescence lifetime imaging microscopy: spatial resolution biochemical processes in the cell," Trends Cell. Biol. 9, 48-52 (1999). [CrossRef] [PubMed]
  19. B. J. Bacskai, J. Skoch, G. A. Hickey, R. Allen and B. T. Hyman, "Fluorescence resonance energy transfer determinations using multiphoton fluorescence lifetime imaging microscopy to characterize amyloid-beta plaques," J. Biomed. Opt. 8, 368-375 (2003). [CrossRef] [PubMed]
  20. Equation (4) is a generalized form of a semi-analytical expression for an infinite medium given in Reference 9, as can be checked by setting t′ →t−t′ and using the analytical expression for the Greens functions with μx a,s =μma,s.
  21. S.R. Arridge, "Optical tomography in medical imaging," Inverse Problems 15, R41 (1999). [CrossRef]
  22. 22. S. Chandrasekhar, Radiative Transfer (Dover, New York, 1960).
  23. F. Gao, H. Zhao, Y. Tanikawa, and Y. Yamada, "A linear, featured-data scheme for image reconstruction in timedomain fluorescence molecular tomography," Opt. Express 14, 7109-7124 (2006). [CrossRef] [PubMed]
  24. M. S. Patterson, B. Chance, and B. C. Wilson, "Time-resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties," Appl. Opt. 28, 2331-2336 (1989). [CrossRef] [PubMed]
  25. J. C. Haselgrove, J. C. Schotland, and J. S. Leigh, "Long-time behavior of photon diffusion in an absorbing medium: application to time-resolved spectroscopy," Appl. Opt. 31, 2678-2683 (1992). [CrossRef] [PubMed]
  26. A. T. N. Kumar, L. Zhu, J. F. Christian, A. A. Demidov, and P. M. Champion, "On the Rate Distribution Analysis of Kinetic Data Using theMaximum EntropyMethod: Applications toMyoglobin Relaxation on the Nanosecond and Femtosecond Timescales," J. Phys. Chem. B. 105, 7847-7856 (2001). [CrossRef]
  27. A. Milstein, J. J. Stott, S. Oh, D. A. Boas, R. P. Millane, C. A. Bouman and K. J. Webb, "Fluorescence optical diffusion tomography using multiple-frequency data," J. Opt. Soc. Am A 21, 1035-1049 (2004). [CrossRef]
  28. A. T. N. Kumar, J. Skoch, F. L. Hammond, A. K. Dunn, D. A. Boas and B. J. Bacskai, "Time resolved fluorescence imaging in diffuse media," Proc. of SPIE 600960090Y, (2005). [CrossRef]
  29. E. E. Graves, J. P. Culver, J. Ripoll, R. Wessleder, V. Ntziachristos, "Singular-value analysis and optimization of experimental parameters in fluorescence molecular tomography," J. Opt. Soc. Am. A 21, 231-241 (2004). [CrossRef]
  30. J. P. Culver, V. Ntziachristos, M. J. Holboke and A. G. Yodh, "Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis," Opt. Lett. 26, 701-703 (2001). [CrossRef]
  31. K. Viswanath and M. Mycek, "Do fluorescence decays remitted from tissues accurately reflect intrinsic fluorophore lifetimes?," Opt. Lett. 29, 1512-1514 (2004). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited