OSA's Digital Library

Optics Express

Optics Express

  • Editor: Michael Duncan
  • Vol. 14, Iss. 25 — Dec. 11, 2006
  • pp: 12552–12559

Changes in aberrations and retinal image quality due to tear film dynamics

Kaccie Y. Li and Geunyoung Yoon  »View Author Affiliations


Optics Express, Vol. 14, Issue 25, pp. 12552-12559 (2006)
http://dx.doi.org/10.1364/OE.14.012552


View Full Text Article

Acrobat PDF (433 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A reliable and objective method to measure aberration changes due to the tear film is essential in improving clinical assessment of the tear film and in vivo retinal imaging. The tear film of 11 subjects are studied by acquiring continuous wavefront measurements in real-time with a customized Shack-Hartmann wavefront sensor. The device has a high resolution lenslet array (190 μm) and a topographer unit with an infrared pupil illuminator (940 nm). A Fourier transform reconstructor algorithm [1] was used to estimate the eyes’ wavefront aberrations from slope measurements. Increasing irregularities in the tear film produced observable wavefront variations. The temporal behavior of tear induced aberrations and retinal image quality was evaluated by the root mean squared (RMS) error of the residual wavefront and the volume modulation transfer function (MTF). Similar trends were observed from both metrics. Our analysis demonstrates the applicability of the SH wavefront sensor to assessing the dynamics of the human tear film.

© 2006 Optical Society of America

OCIS Codes
(170.3890) Medical optics and biotechnology : Medical optics instrumentation
(330.4300) Vision, color, and visual optics : Vision system - noninvasive assessment
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices
(330.5370) Vision, color, and visual optics : Physiological optics

ToC Category:
Vision and color

History
Original Manuscript: September 12, 2006
Manuscript Accepted: October 9, 2006
Published: December 11, 2006

Virtual Issues
Vol. 2, Iss. 1 Virtual Journal for Biomedical Optics

Citation
Kaccie Y. Li and Geunyoung Yoon, "Changes in aberrations and retinal image quality due to tear film dynamics," Opt. Express 14, 12552-12559 (2006)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-25-12552


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. F. Roddier, and C. Roddier, "Wave-front reconstruction using Iterative Fourier-Transforms," Appl. Opt. 30, 1325-1327 (1991).
  2. H. Hofer, P. Artal, B. Singer, J. L. Aragon, and D. R. Williams, "Dynamics of the eye's wave aberration," J. Opt. Soc. Am. A 18, 497-506 (2001).
  3. R. Montes-Mico, J. L. Alio, and W. N. Charman, "Dynamic changes in the tear film in dry eyes," Invest. Ophthalmol. Visual Sci. 46, 1615-1619 (2005). [CrossRef]
  4. J. Craig, "Structure and function of the preocular tear film," in The Tear Film: Structure, Function and Clinical Examination, R. Edwards, and C. Hutchins, eds. (Butterworth-Heinemann, 2002), pp. 18-50.
  5. R. Montes-Mico, J. L. Alio, G. Munoz, J. J. Perez-Santonja, and W. N. Charman, "Postblink changes in total and corneal ocular aberrations," Ophthalmology 111, 758-767 (2004).
  6. R. Tutt, A. Bradley, C. Begley, and L. N. Thibos, "Optical and visual impact of tear break-up in human eyes," Invest. Ophthalmol. Visual Sci. 41, 4117-4123 (2000).
  7. A. Dubra, C. Paterson, and C. Dainty, "Study of the tear topography dynamics using a lateral shearing interferometer," Opt. Express 12, 6278-6288 (2004).
  8. S. Gruppetta, F. Lacombe, and P. Puget, "Study of the dynamic aberrations of the human tear film," Opt. Express 13, 7631-7636 (2005). [CrossRef]
  9. D. R. Iskander, M. J. Collins, and B. Davis, "Evaluating tear film stability in the human eye with high-speed videokeratoscopy," IEEE Trans. Biomed. Eng. 52, 1939-1949 (2005). [CrossRef]
  10. J. Nemeth, B. Erdelyi, B. Csakany, M. Gaspar, A. Soumelidis, F. Kablesz, and Z. Lang, "High-speed videotopographic measurement of tear film build-up time," Invest. Ophthalmol. Visual Sci. 43, 1783-1790 (2002).
  11. L. A. Carvalho, "Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye," Invest. Ophthalmol. Visual Sci. 46, 1915-1926 (2005). [CrossRef]
  12. M. K. Smolek, and S. D. Klyce, "Zernike polynomial fitting fails to represent all visually significant corneal aberrations," Invest. Ophthalmol. Visual Sci. 44, 4676-4681 (2003). [CrossRef]
  13. J. C. Wyant, and K. Creath, "Basic wavefront aberration theory for optical metrology," in Applied Optics and Optical Engineering, J. C. Wyant, and R. R. Shannon, eds. (Academic Press, 1992), pp. 2-53.
  14. W. H. Southwell, "Wave-front estimation from wave-front slope measurements," J. Opt. Soc. Am. 70, 998-1009 (1980).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: AVI (2963 KB)     
» Media 2: AVI (2609 KB)     
» Media 3: AVI (3196 KB)     
» Media 4: AVI (3511 KB)     
» Media 5: AVI (4278 KB)     

« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited