Abstract

This paper reports on the optimization and assessment of a hyperspectral imaging-based spatially-resolved system for determination of the optical properties of biological materials over the wavelengths of 500-1,000 nm. Twelve model samples covering a wide range of absorption and reduced scattering coefficients were created to validate the hyperspectral imaging system, and their true values of absorption and reduced scattering coefficients were determined and then cross-validated using three commonly used methods (i.e., transmittance, integrating sphere, and empirical equation). Light beam and source-detector distance were optimized through Monte Carlo simulations and experiments for the model samples. The optimal light beam should be of Gaussian type with the diameter of less than 1 mm, and the optimal minimum and maximum source-detector distance should be 1.5 mm and 10-20 mean free paths, respectively. The optimized hyperspectral imaging-based spatially-resolved system achieved good estimation of the optical parameters.

© 2010 OSA

OCIS Codes
(170.0110) Medical optics and biotechnology : Imaging systems
(170.3660) Medical optics and biotechnology : Light propagation in tissues
(290.0290) Scattering : Scattering
(300.1030) Spectroscopy : Absorption

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: May 24, 2010
Revised Manuscript: July 12, 2010
Manuscript Accepted: July 21, 2010
Published: July 30, 2010

Virtual Issues
Vol. 5, Iss. 12 Virtual Journal for Biomedical Optics

Citation
Haiyan Cen and Renfu Lu, "Optimization of the hyperspectral imaging-based spatially-resolved system for measuring the optical properties of biological materials," Opt. Express 18, 17412-17432 (2010)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-18-16-17412


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. N. Shah, A. Cerussi, C. Eker, J. Espinoza, J. Butler, J. Fishkin, R. Hornung, and B. Tromberg, “Noninvasive functional optical spectroscopy of human breast tissue,” Proc. Natl. Acad. Sci. U.S.A. 98(8), 4420–4425 (2001). [CrossRef] [PubMed]
  2. J. Welzel, C. Reinhardt, E. Lankenau, C. Winter, and H. H. Wolff, “Changes in function and morphology of normal human skin: evaluation using optical coherence tomography,” Br. J. Dermatol. 150(2), 220–225 (2004). [CrossRef] [PubMed]
  3. B. C. Wilson and M. S. Patterson, “The physics, biophysics and technology of photodynamic therapy,” Phys. Med. Biol. 53(9), R61–R109 (2008). [CrossRef] [PubMed]
  4. A. Torricelli, V. Quaresima, A. Pifferi, G. Biscotti, L. Spinelli, P. Taroni, M. Ferrari, and R. Cubeddu, “Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy,” Phys. Med. Biol. 49(5), 685–699 (2004). [CrossRef] [PubMed]
  5. A. V. Bykov, M. Y. Kirillin, A. V. Priezzhev, and R. Myllyla, “Simulations of a spatially resolved reflectometry signal from a highly scattering three-layer medium applied to the problem of glucose sensing in human skin,” Quantum Electron. 36(12), 1125–1130 (2006). [CrossRef]
  6. R. Cubeddu, C. D’Andrea, A. Pifferi, P. Taroni, A. Torricelli, G. Valentini, C. Dover, D. Johnson, M. Ruiz-Altisent, and C. Valero, “Nondestructive quantification of chemical and physical properties of fruits by time-resolved reflectance spectroscopy in the wavelength range 650-1000 nm,” Appl. Opt. 40(4), 538–543 (2001). [CrossRef] [PubMed]
  7. J. Qin and R. Lu, “Measurement of the optical properties of fruits and vegetables using spatially resolved hyperspectral diffuse reflectance imaging technique,” Postharvest Biol. Technol. 49(3), 355–365 (2008). [CrossRef]
  8. W. Saeys, M. A. Velazco-Roa, S. N. Thennadil, H. Ramon, and B. M. Nicolaï, “Optical properties of apple skin and flesh in the wavelength range from 350 to 2200 nm,” Appl. Opt. 47(7), 908–919 (2008). [CrossRef] [PubMed]
  9. V. Tuchin, Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis (SPIE PRESS, Bellingham, Washington, USA, 2000).
  10. T. Svensson, J. Swartling, P. Taroni, A. Torricelli, P. Lindblom, C. Ingvar, and S. Andersson-Engels, “Characterization of normal breast tissue heterogeneity using time-resolved near-infrared spectroscopy,” Phys. Med. Biol. 50(11), 2559–2571 (2005). [CrossRef] [PubMed]
  11. B. Cletus, R. Künnemeyer, P. Martinsen, A. McGlone, and R. Jordan, “Characterizing liquid turbid media by frequency-domain photon-migration spectroscopy,” J. Biomed. Opt. 14(2), 024041 (2009). [CrossRef] [PubMed]
  12. J. S. Dam, C. B. Pedersen, T. Dalgaard, P. E. Fabricius, P. Aruna, and S. Andersson-Engels, “Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths,” Appl. Opt. 40(7), 1155–1164 (2001). [CrossRef] [PubMed]
  13. R. M. P. Doornbos, R. Lang, M. C. Aalders, F. W. Cross, and H. J. Sterenborg, “The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy,” Phys. Med. Biol. 44(4), 967–981 (1999). [CrossRef] [PubMed]
  14. M. Pilz, S. Honold, and A. Kienle, “Determination of the optical properties of turbid media by measurements of the spatially resolved reflectance considering the point-spread function of the camera system,” J. Biomed. Opt. 13(5), 054047 (2008). [CrossRef] [PubMed]
  15. H. Cen and R. Lu, “Quantification of the optical properties of two-layer turbid materials using a hyperspectral imaging-based spatially-resolved technique,” Appl. Opt. 48(29), 5612–5623 (2009). [CrossRef] [PubMed]
  16. J. Qin and R. Lu, “Measurement of the absorption and scattering properties of turbid liquid foods using hyperspectral imaging,” Appl. Spectrosc. 61(4), 388–396 (2007). [CrossRef] [PubMed]
  17. S. A. Prahl, M. J. C. Vangemert, and A. J. Welch, “Determining the optical-properties of turbid media by using the adding-doubling method,” Appl. Opt. 32(4), 559–568 (1993). [CrossRef] [PubMed]
  18. H. J. van Staveren, C. J. M. Moes, J. Vanmarle, S. A. Prahl, and M. J. C. Vangemert, “Light-scattering in intralipid-10% in the wavelength range of 400-1100 nm,” Appl. Opt. 30(31), 4507–4514 (1991). [CrossRef] [PubMed]
  19. H. Cen, R. Lu, and K. Dolan, “Optimization of inverse algorithm for estimating the optical properties of biological materials using spatially-resolved diffuse reflectance,” Inverse Probl. Sci. En., First published on: 29 June 2010 (iFirst).
  20. A. Ishimaru, Wave Propagation and Scattering in Random Media, Vol. 1: Single Scattering and Transport Theory (Academic Press, New York, NY, 1978).
  21. R. C. Haskell, L. O. Svaasand, T. T. Tsay, T. C. Feng, M. S. McAdams, and B. J. Tromberg, “Boundary conditions for the diffusion equation in radiative transfer,” J. Opt. Soc. Am. A 11(10), 2727–2741 (1994). [CrossRef] [PubMed]
  22. A. Kienle and M. S. Patterson, “Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium,” J. Opt. Soc. Am. A 14(1), 246–254 (1997). [CrossRef] [PubMed]
  23. B. H. Yuan, N. G. Chen, and Q. Zhu, “Emission and absorption properties of indocyanine green in Intralipid solution,” J. Biomed. Opt. 9(3), 497–503 (2004). [CrossRef] [PubMed]
  24. R. Lu and Y. R. Chen, “Hyperspectral imaging system for safety inspection of food and agricultural products,” Proc. SPIE 3544, 121–133 (1999). [CrossRef]
  25. T. Z. Ren, Z. Y. Yuan, and B. L. Su, “Encapsulation of direct blue dye into mesoporous silica-based materials,” Colloid. Surface A. 300(1-2), 79–87 (2007). [CrossRef]
  26. L. H. Wang, S. L. Jacques, and L. Q. Zheng, “CONV--convolution for responses to a finite diameter photon beam incident on multi-layered tissues,” Comput. Methods Programs Biomed. 54(3), 141–150 (1997). [CrossRef] [PubMed]
  27. L. H. Wang, S. L. Jacques, and L. Q. Zheng, “MCML - Monte Carlo modeling of light transport in multilayered tissues,” Comput. Methods Prog. Bio. 47(2), 131–146 (1995). [CrossRef]
  28. G. M. Hale and M. R. Querry, “Optical constants of water in 200 nm to 200 µm wavelegnth region,” Appl. Opt. 12(3), 555–563 (1973). [CrossRef] [PubMed]
  29. A. Giusto, R. Saija, M. A. Iatì, P. Denti, F. Borghese, and O. I. Sindoni, “Optical properties of high-density dispersions of particles: application to intralipid solutions,” Appl. Opt. 42(21), 4375–4380 (2003). [CrossRef] [PubMed]
  30. G. Zaccanti, S. Del Bianco, and F. Martelli, “Measurements of optical properties of high-density media,” Appl. Opt. 42(19), 4023–4030 (2003). [CrossRef] [PubMed]
  31. M. G. Nichols, E. L. Hull, and T. H. Foster, “Design and testing of a white-light, steady-state diffuse reflectance spectrometer for determination of optical properties of highly scattering systems,” Appl. Opt. 36(1), 93–104 (1997). [CrossRef] [PubMed]
  32. T. J. Farrell, M. S. Patterson, and B. Wilson, “A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo,” Med. Phys. 19(4), 879–888 (1992). [CrossRef] [PubMed]
  33. T. H. Pham, F. Bevilacqua, T. Spott, J. S. Dam, B. J. Tromberg, and S. Andersson-Engels, “Quantifying the absorption and reduced scattering coefficients of tissuelike turbid media over a broad spectral range with noncontact Fourier-transform hyperspectral imaging,” Appl. Opt. 39(34), 6487–6497 (2000). [CrossRef] [PubMed]
  34. C. Chen, J. Q. Lu, H. F. Ding, K. M. Jacobs, Y. Du, and X. H. Hu, “A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630 nm,” Opt. Express 14(16), 7420–7435 (2006). [CrossRef] [PubMed]
  35. S. Prahl, “Optical absorption of water” (1998). http://omlc.ogi.edu/spectra/water/index.html .
  36. F. Martelli and G. Zaccanti, “Calibration of scattering and absorption properties of a liquid diffusive medium at NIR wavelengths. CW method,” Opt. Express 15(2), 486–500 (2007). [CrossRef] [PubMed]
  37. J. R. Mourant, T. Fuselier, J. Boyer, T. M. Johnson, and I. J. Bigio, “Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms,” Appl. Opt. 36(4), 949–957 (1997). [CrossRef] [PubMed]
  38. R. Bays, G. Wagnieres, D. Robert, D. Braichotte, J. F. Savary, P. Monnier, and H. van den Bergh, “Clinical determination of tissue optical properties by endoscopic spatially resolved reflectometry,” Appl. Opt. 35(10), 1756–1766 (1996). [CrossRef] [PubMed]
  39. A. Pifferi, A. Torricelli, A. Bassi, P. Taroni, R. Cubeddu, H. Wabnitz, D. Grosenick, M. Möller, R. Macdonald, J. Swartling, T. Svensson, S. Andersson-Engels, R. L. P. van Veen, H. J. Sterenborg, J. M. Tualle, H. L. Nghiem, S. Avrillier, M. Whelan, and H. Stamm, “Performance assessment of photon migration instruments: the MEDPHOT protocol,” Appl. Opt. 44(11), 2104–2114 (2005). [CrossRef] [PubMed]
  40. S. Spichtig, R. Hornung, D. W. Brown, D. Haensse, and M. Wolf, “Multifrequency frequency-domain spectrometer for tissue analysis,” Rev. Sci. Instrum. 80(2), 024301 (2009). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited