Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography

Tong Wu, Zhihua Ding, Ling Wang, and Minghui Chen  »View Author Affiliations


Optics Express, Vol. 19, Issue 19, pp. 18430-18439 (2011)
http://dx.doi.org/10.1364/OE.19.018430


View Full Text Article

Enhanced HTML    Acrobat PDF (2236 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We propose an efficient direct k-domain interpolation based on spectral phase in swept-source optical coherence tomography (SS-OCT). Both the calibration signal from the Mach-Zehnder interferometer (MZI) and the OCT imaging signal from the Michelson interferometer sharing the same swept source are detected and digitized simultaneously. Sufficient sampling of the OCT imaging signal with uniform k interval are directly interpolated in the k-domain based on the spectral phase derived from MZI calibration signal. Depth profile is then obtained from Fourier transform of the k-domain interpolated data. In vivo imaging of human finger skin and nail fold are conducted. Reconstructed images corresponding to different calibration methods are evaluated for comparison. Experimental results demonstrate that improved imaging quality with enhanced resolution and signal-to-noise ratio is realized by the proposed method in contrast to the spectral phase based time-domain interpolation method as well as the intensity based calibration method.

© 2011 OSA

OCIS Codes
(110.2350) Imaging systems : Fiber optics imaging
(170.4500) Medical optics and biotechnology : Optical coherence tomography

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: July 5, 2011
Revised Manuscript: August 13, 2011
Manuscript Accepted: August 22, 2011
Published: September 6, 2011

Virtual Issues
Vol. 6, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Tong Wu, Zhihua Ding, Ling Wang, and Minghui Chen, "Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography," Opt. Express 19, 18430-18439 (2011)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-19-19-18430


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, “Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography,” Opt. Lett.28(21), 2067–2069 (2003). [CrossRef] [PubMed]
  2. R. Leitgeb, C. Hitzenberger, and A. Fercher, “Performance of fourier domain vs. time domain optical coherence tomography,” Opt. Express11(8), 889–894 (2003). [CrossRef] [PubMed]
  3. M. Choma, M. Sarunic, C. Yang, and J. Izatt, “Sensitivity advantage of swept source and Fourier domain optical coherence tomography,” Opt. Express11(18), 2183–2189 (2003). [CrossRef] [PubMed]
  4. A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, “Measurement of intraocular distances by backscattering spectral interferometry,” Opt. Commun.117(1-2), 43–48 (1995). [CrossRef]
  5. S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, “Optical coherence tomography using a frequency-tunable optical source,” Opt. Lett.22(5), 340–342 (1997). [CrossRef] [PubMed]
  6. V. Gelikonov, G. Gelikonov, and P. Shilyagin, “Linear-wavenumber spectrometer for high-speed spectral-domain optical coherence tomography,” Opt. Spectrosc.106(3), 459–465 (2009). [CrossRef]
  7. C. M. Eigenwillig, B. R. Biedermann, G. Palte, and R. Huber, “K-space linear Fourier domain mode locked laser and applications for optical coherence tomography,” Opt. Express16(12), 8916–8937 (2008). [CrossRef] [PubMed]
  8. S. Yun, G. Tearney, J. de Boer, N. Iftimia, and B. Bouma, “High-speed optical frequency-domain imaging,” Opt. Express11(22), 2953–2963 (2003). [CrossRef] [PubMed]
  9. J. Zhang, J. S. Nelson, and Z. Chen, “Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator,” Opt. Lett.30(2), 147–149 (2005). [CrossRef] [PubMed]
  10. M. A. Choma, K. Hsu, and J. A. Izatt, “Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source,” J. Biomed. Opt.10(4), 044009 (2005). [CrossRef] [PubMed]
  11. R. Huber, M. Wojtkowski, K. Taira, J. Fujimoto, and K. Hsu, “Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles,” Opt. Express13(9), 3513–3528 (2005). [CrossRef] [PubMed]
  12. R. Huber, M. Wojtkowski, J. G. Fujimoto, J. Y. Jiang, and A. E. Cable, “Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm,” Opt. Express13(26), 10523–10538 (2005). [CrossRef] [PubMed]
  13. J. Xi, L. Huo, J. Li, and X. Li, “Generic real-time uniform K-space sampling method for high-speed swept-source optical coherence tomography,” Opt. Express18(9), 9511–9517 (2010). [CrossRef] [PubMed]
  14. T. Wu, Z. H. Ding, K. Wang, and C. Wang, “Swept source optical coherence tomography based on non-uniform discrete Fourier transform,” Chin. Opt. Lett.7(10), 941–944 (2009). [CrossRef]
  15. D. Hillmann, G. Huttmann, and P. Koch, “Using nonequispaced fast Fourier transformation to process optical coherence tomography signals,” Proc. SPIE7372, 73720R, 73720R-6 (2009). [CrossRef]
  16. Y. Zhang, X. Li, L. Wei, K. Wang, Z. Ding, and G. Shi, “Time-domain interpolation for Fourier-domain optical coherence tomography,” Opt. Lett.34(12), 1849–1851 (2009). [CrossRef] [PubMed]
  17. S. Vergnole, D. Lévesque, and G. Lamouche, “Experimental validation of an optimized signal processing method to handle non-linearity in swept-source optical coherence tomography,” Opt. Express18(10), 10446–10461 (2010). [CrossRef] [PubMed]
  18. C. Dorrer, N. Belabas, J.-P. Likforman, and M. Joffre, “Spectral resolution and sampling issues in Fourier-transform spectral interferometry,” J. Opt. Soc. Am. B17(10), 1795–1802 (2000). [CrossRef]
  19. Y. Yasuno, V. D. Madjarova, S. Makita, M. Akiba, A. Morosawa, C. Chong, T. Sakai, K.-P. Chan, M. Itoh, and T. Yatagai, “Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments,” Opt. Express13(26), 10652–10664 (2005). [CrossRef] [PubMed]
  20. M. Gora, K. Karnowski, M. Szkulmowski, B. J. Kaluzny, R. Huber, A. Kowalczyk, and M. Wojtkowski, “Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range,” Opt. Express17(17), 14880–14894 (2009). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited