OSA's Digital Library

Optics Express

Optics Express

  • Editor: C. Martijn de Sterke
  • Vol. 19, Iss. 19 — Sep. 12, 2011
  • pp: 18729–18741

Frequency domain depth filtering of integral imaging

Jae-Hyeung Park and Kyeong-Min Jeong  »View Author Affiliations


Optics Express, Vol. 19, Issue 19, pp. 18729-18741 (2011)
http://dx.doi.org/10.1364/OE.19.018729


View Full Text Article

Enhanced HTML    Acrobat PDF (2548 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A novel technique for depth filtering of integral imaging is proposed. Integral imaging captures spatio-angular distribution of the light rays which delivers three-dimensional information of the object scene. The proposed method performs filtering operation in the frequency domain of the captured spatio-angular light ray distribution, achieving depth selective reconstruction. Grating projection further enhances the depth discrimination performance. The principle is verified experimentally.

© 2011 OSA

OCIS Codes
(100.6890) Image processing : Three-dimensional image processing
(110.2990) Imaging systems : Image formation theory
(110.6880) Imaging systems : Three-dimensional image acquisition

ToC Category:
Imaging Systems

History
Original Manuscript: July 19, 2011
Revised Manuscript: August 21, 2011
Manuscript Accepted: August 29, 2011
Published: September 9, 2011

Citation
Jae-Hyeung Park and Kyeong-Min Jeong, "Frequency domain depth filtering of integral imaging," Opt. Express 19, 18729-18741 (2011)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-19-19-18729


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. F. Okano, H. Hoshino, J. Arai, and I. Yuyama, “Real-time pickup method for a three-dimensional image based on integral photography,” Appl. Opt.36(7), 1598–1603 (1997). [CrossRef] [PubMed]
  2. N. Davies, M. McCormick, and L. Yang, “Three-dimensional imaging systems: a new development,” Appl. Opt.27(21), 4520 (1988). [CrossRef] [PubMed]
  3. S.-W. Min, J. Kim, and B. Lee, “New characteristic equation of three-dimensional integral imaging system and its applications,” Jpn. J. Appl. Phys.44(2), L71–L74 (2005). [CrossRef]
  4. R. Martinez-Cuenca, A. Pons, G. Saavedra, M. Martinez-Corral, and B. Javidi, “Optically-corrected elemental images for undistorted Integral image display,” Opt. Express14(21), 9657–9663 (2006). [CrossRef] [PubMed]
  5. J. Arai, M. Okui, T. Yamashita, and F. Okano, “Integral three-dimensional television using a 2000-scanning-line video system,” Appl. Opt.45(8), 1704–1712 (2006). [CrossRef] [PubMed]
  6. H. Liao, T. Dohi, and M. Iwahara, “Improved viewing resolution of integral videography by use of rotated prism sheets,” Opt. Express15(8), 4814–4822 (2007). [CrossRef] [PubMed]
  7. J. Hahn, Y. Kim, and B. Lee, “Uniform angular resolution integral imaging display with boundary folding mirrors,” Appl. Opt.48(3), 504–511 (2009). [CrossRef] [PubMed]
  8. J. Kim, S.-W. Min, and B. Lee, “Viewing window expansion of integral floating display,” Appl. Opt.48(5), 862–867 (2009). [CrossRef] [PubMed]
  9. Y. Kim, H. Choi, J. Kim, S.-W. Cho, Y. Kim, G. Park, and B. Lee, “Depth-enhanced integral imaging display system with electrically variable image planes using polymer-dispersed liquid-crystal layers,” Appl. Opt.46(18), 3766–3773 (2007). [CrossRef] [PubMed]
  10. J.-H. Jung, Y. Kim, Y. Kim, J. Kim, K. Hong, and B. Lee, “Integral imaging system using an electroluminescent film backlight for three-dimensional-two-dimensional convertibility and a curved structure,” Appl. Opt.48(5), 998–1007 (2009). [CrossRef] [PubMed]
  11. M. Shin, G. Baasantseren, K.-C. Kwon, N. Kim, and J.-H. Park, “Three-dimensional display system based on integral imaging with viewing direction control,” Jpn. J. Appl. Phys.49(7), 0725011–0725017 (2010). [CrossRef]
  12. J.-Y. Son, B. Javidi, S. Yano, and K.-H. Choi, “Recent Developments in 3-D Imaging Technologies,” J. Display Technol.6(10), 394–403 (2010). [CrossRef]
  13. J.-H. Park, K. Hong, and B. Lee, “Recent progress in three-dimensional information processing based on integral imaging,” Appl. Opt.48(34), H77–H94 (2009). [CrossRef] [PubMed]
  14. M. Levoy, R. Ng, A. Adams, M. Footer, and M. Horowitz, “Light field microscopy,” ACM Trans. on Graphics (Proc. SIGGRAPH) 25, 924–934 (2006).
  15. J.-H. Jung, K. Hong, G. Park, I. Chung, J.-H. Park, and B. Lee, “Reconstruction of three-dimensional occluded object using optical flow and triangular mesh reconstruction in integral imaging,” Opt. Express18(25), 26373–26387 (2010). [CrossRef] [PubMed]
  16. B. Javidi, I. Moon, and S. Yeom, “Three-dimensional identification of biological microorganism using integral imaging,” Opt. Express14(25), 12096–12108 (2006). [CrossRef] [PubMed]
  17. G. Passalis, N. Sgouros, S. Athineos, and T. Theoharis, “Enhanced reconstruction of three-dimensional shape and texture from integral photography images,” Appl. Opt.46(22), 5311–5320 (2007). [CrossRef] [PubMed]
  18. J.-H. Park, G. Baasantseren, N. Kim, G. Park, J.-M. Kang, and B. Lee, “View image generation in perspective and orthographic projection geometry based on integral imaging,” Opt. Express16(12), 8800–8813 (2008). [CrossRef] [PubMed]
  19. T. Mishina, M. Okui, and F. Okano, “Calculation of holograms from elemental images captured by integral photography,” Appl. Opt.45(17), 4026–4036 (2006). [CrossRef] [PubMed]
  20. N. T. Shaked, J. Rosen, and A. Stern, “Integral holography: white-light single-shot hologram acquisition,” Opt. Express15(9), 5754–5760 (2007). [CrossRef] [PubMed]
  21. J.-H. Park, M.-S. Kim, G. Baasantseren, and N. Kim, “Fresnel and Fourier hologram generation using orthographic projection images,” Opt. Express17(8), 6320–6334 (2009). [CrossRef] [PubMed]
  22. S.-H. Hong, J.-S. Jang, and B. Javidi, “Three-dimensional volumetric object reconstruction using computational integral imaging,” Opt. Express12(3), 483–491 (2004). [CrossRef] [PubMed]
  23. J.-B. Hyun, D.-C. Hwang, D.-H. Shin, and E.-S. Kim, “Curved computational integral imaging reconstruction technique for resolution-enhanced display of three-dimensional object images,” Appl. Opt.46(31), 7697–7708 (2007). [CrossRef] [PubMed]
  24. B. Javidi and Y. S. Hwang, “Passive near-infrared 3D sensing and computational reconstruction with synthetic aperture integral imaging,” J. Display Technol.4(1), 3–5 (2008). [CrossRef]
  25. K.-J. Lee, D.-C. Hwang, S.-C. Kim, and E.-S. Kim, “Blur-metric-based resolution enhancement of computationally reconstructed integral images,” Appl. Opt.47(15), 2859–2869 (2008). [CrossRef] [PubMed]
  26. G. Baasantseren, J.-H. Park, and N. Kim, “Depth discrimination enhanced computational integral imaging using random pattern illumination,” Jpn. J. Appl. Phys.48(2), 0202161–0202163 (2009). [CrossRef]
  27. J.-X. Chai, S.-C. Chan, H.-Y. Shum, and X. Tong, “Plenoptic sampling,” Proc. ACM SIGGRAPH, 307–318 (2000).
  28. X. Chen, M. Gramaglia, and J. A. Yeazell, “Phase-shift calibration algorithm for phase-shifting interferometry,” J. Opt. Soc. Am. A17(11), 2061–2066 (2000). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: AVI (1516 KB)     
» Media 2: AVI (1628 KB)     
» Media 3: AVI (2060 KB)     
» Media 4: AVI (2052 KB)     
» Media 5: AVI (2028 KB)     
» Media 6: AVI (2004 KB)     

« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited