Pulse oximeter is widely used in the monitoring of blood oxygen in clinic for its convenience and efficiency. However, synchronizing light source flashing with data collecting is required, otherwise the separation of the data from different LEDs will fail. More importantly, synchronous acquisition makes the pulse oximetry system vulnerable. Meanwhile, the pulse waveform extraction is a crucial procedure in the measurement. Hence, in this paper, an asynchronous acquisition pulse oximetry system based on wavelet transform has been built. PhotoPlethysmoGraph (PPG) and photoelectric detection technology are applied in our homemade system. The adaptive soft-threshold de-noising is realized by Stein's Unbiased Risk Estimate (SURE). The principle and system configuration are described. The preliminary experiment results from wavelet transforms and Fourier transforms are compared. The results show that our homemade system is adaptive, accurate, robust and simple.

© 2013 Optical Society of America

OCIS Codes
(000.3110) General : Instruments, apparatus, and components common to the sciences
(230.0230) Optical devices : Optical devices
(230.3670) Optical devices : Light-emitting diodes
(220.1080) Optical design and fabrication : Active or adaptive optics

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: June 24, 2013
Revised Manuscript: September 10, 2013
Manuscript Accepted: September 12, 2013
Published: September 23, 2013

Citation
Shengjia Wang, Zhan Gao, Guangyu Li, and Ziang Feng, "Adaptive pulse oximeter with dual-wavelength based on wavelet transforms," Opt. Express 21, 23058-23067 (2013)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-21-20-23058


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. T. Aoyagi, M. Kishi, K. Yamaguchi, and S. Watanabe, “Improvement of the earpiece oximeter,” in Abstracts of the Japanese Society of Medical Electronics and Biological Engineering (Japanese Society of Medical Electronics and Biological Engineering, Tokyo, 1974), pp. 90–91.
  2. S. A. Wilber, “Blood constituent measuring device and method,” U.S. Patent No. 4,407,290, Washington, DC: U.S. Patent and Trademark Office (1983).
  3. P. S. Addison and J. N. Watson, “A novel time–frequency-based 3D Lissajous figure method and its application to the determination of oxygen saturation from the photoplethysmogram,” Meas. Sci. Technol.15(11), L15–L18 (2004). [CrossRef]
  4. Y. S. Yan and Y. T. Zhang, “An efficient motion-resistant method for wearable pulse oximeter,” IEEE Trans. Inf. Technol. Biomed.12(3), 399–405 (2008). [CrossRef] [PubMed]
  5. F. U. Dowla, P. G. Skokowski, and R. R. Leach, Jr., “Neural networks and wavelet analysis in the computer interpretation of pulse oximetry data,” in Proceedings of IEEE Conference on Neural Networks for Signal Processing (IEEE Signal Processing Society Workshop, Kyoto, 1996), pp. 527–536. [CrossRef]
  6. S. Lee, B. L. Ibey, W. Xu, M. A. Wilson, M. N. Ericson, and G. L. Coté, “Processing of pulse oximeter data using discrete wavelet analysis,” IEEE Trans. Biomed. Eng.52(7), 1350–1352 (2005). [CrossRef] [PubMed]
  7. Y. Yong-sheng, C. Y. Poon Carmen, and Z. Yuan-ting, “Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution,” J. NeuroEng. Rehabil.2(3), 9 (2005).
  8. X. U. Kexin, G. A. O. Feng, and Z. H. A. O. Huijuan, Biomedical Photonics, 2nd ed. (Science Press, 2010), p. 182.
  9. C. M. Stein, “Estimation of the mean of a multivariate normal distribution,” Ann. Stat.9(6), 1135–1151 (1981). [CrossRef]
  10. D. L. Donoho and I. M. Johnstone, “Adapting to unknown smoothness via wavelet shrinkage,” J. Am. Stat. Assoc.90(432), 1200–1224 (1995). [CrossRef]
  11. J. A. Dempsey and P. D. Wagner, “Exercise-induced arterial hypoxemia,” J. Appl. Physiol.87(6), 1997–2006 (1999). [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited