Phase-diverse Fresnel coherent diffractive imaging of malaria parasite-infected red blood cells in the water window

M. W.M. Jones, B. Abbey, A. Gianoncelli, E. Balaur, C. Millet, M. B Luu, H. D. Coughlan, A. J. Carroll, A. G. Peele, L. Tilley, and G. A. van Riessen  »View Author Affiliations


Optics Express, Vol. 21, Issue 26, pp. 32151-32159 (2013)
http://dx.doi.org/10.1364/OE.21.032151


View Full Text Article

Enhanced HTML    Acrobat PDF (1680 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Phase-diverse Fresnel coherent diffractive imaging has been shown to reveal the structure and composition of biological specimens with high sensitivity at nanoscale resolution. However, the method has yet to be applied using X-ray illumination with energy in the so-called ‘water-window’ that lies between the carbon and oxygen K edges. In this range, differences in the strength of the X-ray interaction for protein based biological materials and water is increased. Here we demonstrate a proof-of-principle application of FCDI at an X-ray energy within the water-window to a dehydrated cellular sample composed of red blood cells infected with the trophozoite stage of the malaria parasite, Plasmodium falciparum. Comparison of the results to both optical and electron microscopy shows that the correlative imaging methods that include water-window FCDI will find utility in studying cellular architecture.

© 2013 Optical Society of America

OCIS Codes
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(340.7440) X-ray optics : X-ray imaging
(340.7460) X-ray optics : X-ray microscopy
(260.6048) Physical optics : Soft x-rays

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: October 14, 2013
Revised Manuscript: November 19, 2013
Manuscript Accepted: November 20, 2013
Published: December 18, 2013

Virtual Issues
Vol. 9, Iss. 2 Virtual Journal for Biomedical Optics

Citation
M. W.M. Jones, B. Abbey, A. Gianoncelli, E. Balaur, C. Millet, M. B Luu, H. D. Coughlan, A. J. Carroll, A. G. Peele, L. Tilley, and G. A. van Riessen, "Phase-diverse Fresnel coherent diffractive imaging of malaria parasite-infected red blood cells in the water window," Opt. Express 21, 32151-32159 (2013)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-21-26-32151


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. P. Mancuso, O. M. Yefanov, and I. A. Vartanyants, “Coherent diffractive imaging of biological samples at synchrotron and free electron laser facilities,” J. Biotechnol.149(4), 229–237 (2010). [CrossRef] [PubMed]
  2. H. Jiang, C. Song, C.-C. Chen, R. Xu, K. S. Raines, B. P. Fahimian, C.-H. Lu, T.-K. Lee, A. Nakashima, J. Urano, T. Ishikawa, F. Tamanoi, and J. Miao, “Quantitative 3D imaging of whole, unstained cells by using X-ray diffraction microscopy,” Proc. Natl. Acad. Sci. U.S.A.107(25), 11234–11239 (2010). [CrossRef] [PubMed]
  3. G. J. Williams, E. Hanssen, A. G. Peele, M. A. Pfeifer, J. N. Clark, B. Abbey, G. Cadenazzi, M. D. de Jonge, S. Vogt, L. Tilley, and K. A. Nugent, “High-resolution X-ray imaging of Plasmodium falciparum-infected red blood cells,” Cytometry A73(10), 949–957 (2008). [CrossRef] [PubMed]
  4. D. Shapiro, P. Thibault, T. Beetz, V. Elser, M. R. Howells, C. Jacobsen, J. Kirz, E. Lima, H. Miao, A. M. Neiman, and D. Sayre, “Biological imaging by soft x-ray diffraction microscopy,” Proc. Natl. Acad. Sci. U.S.A.102(43), 15343–15346 (2005). [CrossRef] [PubMed]
  5. A. P. Mancuso, M. R. Groves, O. E. Polozhentsev, G. J. Williams, I. McNulty, C. Antony, R. Santarella-Mellwig, A. V. Soldatov, V. Lamzin, A. G. Peele, K. A. Nugent, and I. A. Vartanyants, “Internal structure of an intact Convallaria majalis pollen grain observed with X-ray Fresnel coherent diffractive imaging,” Opt. Express20(24), 26778–26785 (2012). [CrossRef] [PubMed]
  6. M. Beckers, T. Senkbeil, T. Gorniak, M. Reese, K. Giewekemeyer, S. C. Gleber, T. Salditt, and A. Rosenhahn, “Chemical contrast in soft x-ray ptychography,” Phys. Rev. Lett.107(20), 208101 (2011). [CrossRef] [PubMed]
  7. M. W. M. Jones, G. A. van Riessen, B. Abbey, C. T. Putkunz, M. D. Junker, E. Balaur, D. J. Vine, I. McNulty, B. Chen, B. D. Arhatari, S. Frankland, K. A. Nugent, L. Tilley, and A. G. Peele, “Whole-cell phase contrast imaging at the nanoscale using Fresnel Coherent Diffractive Imaging Tomography,” Sci. Rep.3, 2288 (2013). [CrossRef] [PubMed]
  8. K. A. Nugent, “Coherent methods in the X-ray sciences,” Adv. Phys.59(1), 1–99 (2010). [CrossRef]
  9. B. Kaulich, P. Thibault, A. Gianoncelli, and M. Kiskinova, “Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications,” J. Phys. Condens. Matter23(8), 083002 (2011). [CrossRef] [PubMed]
  10. D. Nam, J. Park, M. Gallagher-Jones, S. Kim, S. Kim, Y. Kohmura, H. Naitow, N. Kunishima, T. Yoshida, T. Ishikawa, and C. Song, “Imaging Fully Hydrated Whole Cells by Coherent X-ray Diffraction Microscopy,” Phys. Rev. Lett.110(9), 098103 (2013). [CrossRef] [PubMed]
  11. K. Giewekemeyer, M. Beckers, T. Gorniak, M. Grunze, T. Salditt, and A. Rosenhahn, “Ptychographic coherent x-ray diffractive imaging in the water window,” Opt. Express19(2), 1037–1050 (2011). [CrossRef] [PubMed]
  12. C. A. Larabell and M. A. Le Gros, “X-ray tomography generates 3-D reconstructions of the yeast, Saccharomyces cerevisiae, at 60-nm resolution,” Mol. Biol. Cell15(3), 957–962 (2003). [CrossRef] [PubMed]
  13. J. Kirz, C. Jacobsen, and M. R. Howells, “Soft X-ray microscopes and their biological applications,” Q. Rev. Biophys.28(1), 33–130 (1995). [CrossRef] [PubMed]
  14. J. M. Rodenburg, A. C. Hurst, A. G. Cullis, B. R. Dobson, F. Pfeiffer, O. Bunk, C. David, K. Jefimovs, and I. Johnson, “Hard-X-ray lensless imaging of extended objects,” Phys. Rev. Lett.98(3), 034801 (2007). [CrossRef] [PubMed]
  15. K. Giewekemeyer, P. Thibault, S. Kalbfleisch, A. Beerlink, C. M. Kewish, M. Dierolf, F. Pfeiffer, and T. Salditt, “Quantitative biological imaging by ptychographic x-ray diffraction microscopy,” Proc. Natl. Acad. Sci. U.S.A.107(2), 529–534 (2010). [CrossRef] [PubMed]
  16. D. J. Vine, G. J. Williams, B. Abbey, M. A. Pfeifer, J. N. Clark, M. D. de Jonge, I. McNulty, A. G. Peele, and K. A. Nugent, “Ptychographic Fresnel coherent diffractive imaging,” Phys. Rev. A80(6), 0638231 (2009). [CrossRef]
  17. C. T. Putkunz, J. N. Clark, D. J. Vine, G. J. Williams, M. A. Pfeifer, E. Balaur, I. McNulty, K. A. Nugent, and A. G. Peele, “Phase-diverse coherent diffractive imaging: high sensitivity with low dose,” Phys. Rev. Lett.106(1), 013903 (2011). [CrossRef] [PubMed]
  18. C. T. Putkunz, J. N. Clark, D. J. Vine, G. J. Williams, E. Balaur, G. A. Cadenazzi, E. K. Curwood, C. A. Henderson, R. E. Scholten, R. J. Stewart, I. McNulty, K. A. Nugent, and A. G. Peele, “Mapping granular structure in the biological adhesive of Phragmatopoma californica using phase diverse coherent diffractive imaging,” Ultramicroscopy111(8), 1184–1188 (2011). [CrossRef] [PubMed]
  19. M. W. M. Jones, M. K. Dearnley, G. A. van Riessen, B. Abbey, C. T. Putkunz, M. D. Junker, D. J. Vine, I. McNulty, K. A. Nugent, A. G. Peele, and L. Tilley, “Rapid, low dose X-ray diffractive imaging of the malaria parasite Plasmodium falciparum,” Ultramicroscopy (2013), doi:. [CrossRef]
  20. J. R. Lakowicz, Principles of Fluorescence Spectrocscopy III ed. (Springer, 2006).
  21. R. N. Wilke, M. Priebe, M. Bartels, K. Giewekemeyer, A. Diaz, P. Karvinen, and T. Salditt, “Hard X-ray imaging of bacterial cells: nano-diffraction and ptychographic reconstruction,” Opt. Express20(17), 19232–19254 (2012). [CrossRef] [PubMed]
  22. W. P. Callahan and J. A. Horner, “The use of vanadium as a stain for electron microscopy,” J. Cell Biol.20(2), 350–356 (1964). [CrossRef] [PubMed]
  23. A. Gianoncelli, G. R. Morrison, B. Kaulich, D. Basescu, and J. Kovac, “Scanning transmission x-ray microspopy with a configuable detector,” Appl. Phys. Lett.89(25), 251117 (2006). [CrossRef]
  24. B. Kaulich, D. Bacescu, J. Susini, C. David, E. Di Fabrizio, G. R. Morrison, P. Charalamous, T. J. T. Wilhein, J. Kovac, D. Cocco, M. Salome, O. Dhez, T. Weitkamp, S. Cabrini, D. Cojoc, A. Gianoncelli, U. Vogt, M. Podnar, M. Zangrando, M. Zacchigna, and M. Kiskinova, “TwinMic - A European twin X-ray microscopy station commissioned at ELETTRA,” Proc. 8th Int. Conf. X-ray Microscopy7, 22–25 (2006).
  25. M. Born and E. Wolf, Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light VII ed. (Cambridge University Press, 1999) p.471.
  26. B. Abbey, K. A. Nugent, G. J. Williams, J. N. Clark, A. G. Peele, M. A. Pfeifer, M. D. de Jonge, and I. McNulty, “Keyhole coherent diffractive imaging,” Nat. Phys.4(5), 394–398 (2008). [CrossRef]
  27. G. J. Williams, H. M. Quiney, B. B. Dhal, C. Q. Tran, K. A. Nugent, A. G. Peele, D. Paterson, and M. D. de Jonge, “Fresnel coherent diffractive imaging,” Phys. Rev. Lett.97(2), 025506 (2006). [CrossRef] [PubMed]
  28. G. J. Williams, H. M. Quiney, A. G. Peele, and K. A. Nugent, “Fresnel coherent diffractive imaging: treatment and analysis of data,” New J. Phys.12(3), 035020 (2010). [CrossRef]
  29. M. R. Howells, T. Beetz, H. N. Chapman, C. Cui, J. M. Holton, C. J. Jacobsen, J. Kirz, E. Lima, S. Marchesini, H. Miao, D. Sayre, D. A. Shapiro, J. C. H. Spence, and D. Starodub, “An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy,” J. Electron Spectrosc. Relat. Phenom.170(1-3), 4–12 (2009). [CrossRef] [PubMed]
  30. M. W. M. Jones, A. G. Peele, and G. A. van Riessen, “Application of a complex constraint for a complex sample in coherent diffractive imaging,” Opt. Express (to be published).
  31. N. Davidson, B. Abbey, H. M. Quiney, T. D. Julius, B. Allman, M. W. M. Jones, C. T. Putkunz, A. Torrance, H. Wittler, A. Carroll, M. B. Luu, and K. A. Nugent, NADIA Software Project http://www.coecxs.org/joomla/index.php/research-and-projects/nadia-software-project.html , ARC Centre of Excellence for Coherent X-ray Science, 2011.
  32. J. N. Clark, C. T. Putkunz, M. A. Pfeifer, A. G. Peele, G. J. Williams, B. Chen, K. A. Nugent, C. Hall, W. Fullagar, S. Kim, and I. McNulty, “Use of a complex constraint in coherent diffractive imaging,” Opt. Express18(3), 1981–1993 (2010). [CrossRef] [PubMed]
  33. B. L. Henke, E. M. Gullikson, and J. C. Davis, “X-ray interactions: photoabsorption, scattering, transmission, and reflection at E=50-30000 eV, Z=1-92,” Atom. Data Nucl. Data54(2), 181–342 (1993). [CrossRef]
  34. T. Aaltonen, M. Ritala, T. Sajavaara, J. Keinonen, and M. Leskela, “Atomic layer deposition of platinum thin films,” Chem. Mater.15(9), 1924–1928 (2003). [CrossRef]
  35. D. Li, Y. Chen, Y.-W. Chung, and F. L. Freire, “Metrology of 1-10 nm thick CNX films: Thickness, density, and surface roughness measurements,” J. Vac. Sci. Technol. A21(5), L19–L21 (2003). [CrossRef]
  36. K. Robbie, L. J. Friedrich, S. K. Dew, T. Smy, and M. J. Brett, “Fabication of thin films with highly porous microstructures,” J. Vac. Sci. Technol. A13(3), 1032–1035 (1995). [CrossRef]
  37. K. A. Telari, B. R. Rogers, H. Fang, L. Shen, R. A. Weller, and D. N. Braski, “Characterization of platinum deposited by focused ion beam-assisted chemical vapor deposition,” J. Vac. Sci. Technol. B20(2), 590–595 (2002). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited