Measurement of wavefront aberrations and lens deformation in the accommodated eye with optical coherence tomography-equipped wavefront system

Ji C. He and Jianhua Wang  »View Author Affiliations


Optics Express, Vol. 22, Issue 8, pp. 9764-9773 (2014)
http://dx.doi.org/10.1364/OE.22.009764


View Full Text Article

Enhanced HTML    Acrobat PDF (1385 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

To quantitatively approach the relationship between optical changes in an accommodated eye and the geometrical deformation of its crystalline lens, a long scan-depth anterior segment OCT equipped wavefront sensor was developed and integrated with a Badal system. With this system, accommodation was stimulated up to 6.0D in the left eye and also measured in the same eye for three subjects. High correlations between the accommodative responses of refractive power and the radius of the anterior lens surface were found for the three subjects (r>0.98). The change in spherical aberration was also highly correlated with the change in lens thickness (r>0.98). The measurement was very well repeated at a 2nd measurement session on the same day for the three subjects and after two weeks for one subject. The novelty of incorporating the Badal system into the OCT equipped wavefront sensor eliminated axial misalignment of the measurement system with the test eye due to accommodative vergence, as in the contralateral paradigm. The design also allowed the wavefront sensor to capture conjugated sharp Hartmann-Shack images in accommodated eyes to accurately analyze wavefront aberrations. In addition, this design extended the accommodation range up to 10.0D. By using this system, for the first time, we demonstrated linear relationships of the changes between the refractive power and the lens curvature and also between the spherical aberration and the lens thickness during accommodation in vivo. This new system provides an accurate and useful technique to quantitatively study accommodation.

© 2014 Optical Society of America

OCIS Codes
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(170.4500) Medical optics and biotechnology : Optical coherence tomography
(170.4580) Medical optics and biotechnology : Optical diagnostics for medicine
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices

ToC Category:
Vision, Color, and Visual Optics

History
Original Manuscript: February 12, 2014
Revised Manuscript: April 9, 2014
Manuscript Accepted: April 10, 2014
Published: April 16, 2014

Virtual Issues
Vol. 9, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Ji C. He and Jianhua Wang, "Measurement of wavefront aberrations and lens deformation in the accommodated eye with optical coherence tomography-equipped wavefront system," Opt. Express 22, 9764-9773 (2014)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-22-8-9764


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. T. Young, “The Bakerian Lecture: On the mechanism of the eye,” Philos. Trans. R. Soc. London 91(0), 23–88 (1801). [CrossRef]
  2. H. von Helmholtz, “Über die Akkommodation des Auges,” Arch. Ophthalmol. 1, 1–74 (1855).
  3. E. F. Fincham, “The mechanism of accommodation,” Br. J. Ophthalmol. 8, 7–80 (1937).
  4. E. F. Fincham, “The proportion of ciliary muscular force required for accommodation,” J. Physiol. 128(1), 99–112 (1955). [PubMed]
  5. B. Graves, “The response of the lens capsules in the act of accommodation,” Trans. Am. Ophthalmol. Soc. 23, 184–198 (1925). [PubMed]
  6. D. A. Atchison, “Accommodation and presbyopia,” Ophthalmic Physiol. Opt. 15(4), 255–272 (1995). [CrossRef] [PubMed]
  7. A. Glasser, “Accommodation: mechanism and measurement,” Ophthalmol. Clin. North Am. 19(1), 1–12 (2006). [PubMed]
  8. W. N. Charman, “The eye in focus: accommodation and presbyopia,” Clin. Exp. Optom. 91(3), 207–225 (2008). [CrossRef] [PubMed]
  9. J. Liang, B. Grimm, S. Goelz, J. F. Bille, “Objective measurement of the wave aberrations of the human eye using a Hartmann–Shack wavefront sensor,” J. Opt. Soc. Am. A 11, 1949–1957 (1994). [CrossRef]
  10. J. Liang, D. R. Williams, “Aberrations and retinal image quality of the normal human eye,” J. Opt. Soc. Am. A 14(11), 2873–2883 (1997). [CrossRef] [PubMed]
  11. J. C. He, S. Marcos, R. H. Webb, S. A. Burns, “Measurement of the wave-front aberration of the eye by a fast psychophysical procedure,” J. Opt. Soc. Am. A 15(9), 2449–2456 (1998). [CrossRef]
  12. J. C. He, S. A. Burns, S. Marcos, “Monochromatic aberrations in the accommodated human eye,” Vision Res. 40(1), 41–48 (2000). [CrossRef] [PubMed]
  13. S. Ninomiya, T. Fujikado, T. Kuroda, N. Maeda, Y. Tano, T. Oshika, Y. Hirohara, T. Mihashi, “Changes of ocular aberration with accommodation,” Am. J. Ophthalmol. 134(6), 924–926 (2002). [CrossRef] [PubMed]
  14. C. A. Hazel, M. J. Cox, N. C. Strang, “Wavefront aberration and its relationship to the accommodative stimulus-response function in myopic subjects,” Optom. Vis. Sci. 80(2), 151–158 (2003). [CrossRef] [PubMed]
  15. H. Cheng, J. K. Barnett, A. S. Vilupuru, J. D. Marsack, S. Kasthurirangan, R. A. Applegate, A. Roorda, “A population study on changes in wave aberrations with accommodation,” J. Vis. 4(4), 272–280 (2004). [CrossRef] [PubMed]
  16. S. Plainis, H. S. Ginis, A. Pallikaris, “The effect of ocular aberrations on steady-state errors of accommodative response,” J. Vis. 5(5), 466–477 (2005). [CrossRef] [PubMed]
  17. A. Glasser, M. C. Campbell, “Presbyopia and the optical changes in the human crystalline lens with age,” Vision Res. 38(2), 209–229 (1998). [CrossRef] [PubMed]
  18. J. G. Fujimoto, S. A. Boppart, G. J. Tearney, B. E. Bouma, C. Pitris, M. E. Brezinski, “High resolution in vivo intra-arterial imaging with optical coherence tomography,” Heart 82(2), 128–133 (1999). [PubMed]
  19. J. G. Fujimoto, B. Bouma, G. J. Tearney, S. A. Boppart, C. Pitris, J. F. Southern, M. E. Brezinski, “New technology for high-speed and high-resolution optical coherence tomography,” Ann. N. Y. Acad. Sci. 838(1), 95–107 (1998). [CrossRef] [PubMed]
  20. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, J. G. Fujimoto, “Optical coherence tomography,” Science 254(5035), 1178–1181 (1991). [CrossRef] [PubMed]
  21. D. Huang, J. Wang, C. P. Lin, C. A. Puliafito, J. G. Fujimoto, “Micron-resolution ranging of cornea anterior chamber by optical reflectometry,” Lasers Surg. Med. 11(5), 419–425 (1991). [CrossRef] [PubMed]
  22. J. A. Izatt, M. R. Hee, E. A. Swanson, C. P. Lin, D. Huang, J. S. Schuman, C. A. Puliafito, J. G. Fujimoto, “Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography,” Arch. Ophthalmol. 112(12), 1584–1589 (1994). [CrossRef] [PubMed]
  23. C. Du, M. Shen, M. Li, D. Zhu, M. R. Wang, J. Wang, “Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography,” Ophthalmology 119(12), 2479–2485 (2012). [CrossRef] [PubMed]
  24. G. Shi, Y. Wang, Y. Yuan, L. Wei, F. Lv, Y. Zhang, “Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation,” J. Biomed. Opt. 17(12), 120501 (2012). [CrossRef] [PubMed]
  25. Y. Yuan, Y. Shao, A. Tao, M. Shen, J. Wang, G. Shi, Q. Chen, D. Zhu, Y. Lian, J. Qu, Y. Zhang, F. Lu, “Ocular anterior segment biometry and high-order wavefront aberrations during accommodation,” Invest. Ophthalmol. Vis. Sci. 54(10), 7028–7037 (2013). [CrossRef] [PubMed]
  26. H. Wang, Y. Pan, A. M. Rollins, “Extending the effective imaging range of Fourier-domain optical coherence tomography using a fiber optic switch,” Opt. Lett. 33(22), 2632–2634 (2008). [CrossRef] [PubMed]
  27. R. Cubalchini, “Modal wave-front estimation from phase derivative measurements,” J. Opt. Soc. Am. 69(7), 972–977 (1979). [CrossRef]
  28. V. N. Mahajan, “Zernike circle polynomials and optical aberrations of systems with circular pupils,” Appl. Opt. 33(34), 8121–8124 (1994). [CrossRef] [PubMed]
  29. L. N. Thibos, R. A. Applegate, J. T. Schweigling, R. WebbVSIA Standards Taskforce Members, “Standards for reporting the optical aberrations of eyes,” J. Refract. Surg. 18, S652–S660 (2002).
  30. M. Zhao, A. N. Kuo, J. A. Izatt, “3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea,” Opt. Express 18(9), 8923–8936 (2010). [CrossRef] [PubMed]
  31. T. O. Salmon, C. van de Pol, “Evaluation of a clinical aberrometer for lower-order accuracy and repeatability, higher-order repeatability, and instrument myopia,” Optometry 76(8), 461–472 (2005). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited