Coherence holography

Mitsuo Takeda, Wei Wang, Zhihui Duan, and Yoko Miyamoto  »View Author Affiliations


Optics Express, Vol. 13, Issue 23, pp. 9629-9635 (2005)
http://dx.doi.org/10.1364/OPEX.13.009629


View Full Text Article

Acrobat PDF (446 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

The principle of unconventional holography, called coherence holography, is proposed and experimentally demonstrated for the first time. An object recorded in a hologram is reconstructed as the three-dimensional distribution of a complex spatial coherence function, rather than as the complex amplitude distribution of the optical field itself that usually represents the reconstructed image in conventional holography. A simple optical geometry for the direct visualization of the reconstructed coherence image is proposed, along with the experimental results validating the proposed principle. Coherence holography is shown to be applicable to optical coherence tomography and profilometry.

© 2005 Optical Society of America

1. Introduction

Conventional holography is a technique that records and reconstructs the 3-D image of an object represented by an optical field distribution itself [1

1 . D. Gabor , “ A new microscopic principle ,” Nature 161 , 777 – 778 ( 1948 ). [CrossRef] [PubMed]

,2

2 . E. N. Leith and J. Upatnieks , “ Reconstructed wavefronts and communication theory ,” J. Opt. Soc. Am. 52 , 1123 – 1130 ( 1962 ). [CrossRef]

]. We propose and demonstrate a new concept of yet another type of holography, which we call coherence holography. In this technique, the information of the 3-D image is encoded into the spatial coherence function of the reconstructed optical field. Instead of detecting the image as the optical field intensity, coherence holography reconstructs the image as the degree of spatial coherence between a pair of points, of which one serves as a reference point R and the other as a probe point P on the object to be reconstructed. The proposed principle of coherence holography will open up new possibilities in recording, synthesizing, and control of a spatial coherence function for applications such as spatial coherence tomography and profilometry [3

3 . J. Rosen and M. Takeda , “ Longitudinal spatial coherence applied for surface profilometry ,” Appl. Opt. 39 , 4107 – 4111 ( 2000 ). [CrossRef]

].

2. Principles

The principle of coherence holography is based on the formal analogy between the diffraction integral and the formula of van Cittert-Zernike theorem [4

4 . M. Born and E. Wolf , Principles of Optics , 4th ed. ( Pergamon, London , 1970 ), Chap. 10.

,5

5 . J. W. Goodman , Statistical Optics , 1st ed. ( Wiley, New York , 1985 ), Chap. 5.

]. For convenience of explanation, let us first consider the case of phase-conjugate reconstruction in conventional holography, in which the illuminating light for recording and reconstruction is highly coherent both temporally and spatially. A three-dimensional object is recorded in a hologram with a spherical reference beam uR (r S) = exp(ik|r S - r R|)/|r S - r R| diverging from a point source R, and then the image is reconstructed by illuminating the hologram with the phase-conjugated reference beam uR* (r S) = exp(-ik|r S - r R|)/|r S - r R| converging into the original reference source point R, as shown in Fig. 1, where r S and r R are position vectors pointing at point S on the hologram and the reference point source R, respectively. Apart from a constant factor, the reconstructed optical field at an arbitrary observation point Q is given by

urQrR=IA(rS)uR*(rS)exp(ikrQrS)rQrSdrS
=IA(rS)exp[ik(rQrSrRrS)]rQrSrRrSdrS,
(1)

where IA(r S) is the amplitude transmittance of the hologram, r Q is the position vector of the observation point Q, and the integration is taken over the hologram.

Fig. 1. Optical fields reconstructed from a conventional hologram with a phase-conjugated reference beam.

It should be noted that Eq. (1) has exactly the same form as the formula for mutual intensity given by van Cittert-Zernike theorem [4

4 . M. Born and E. Wolf , Principles of Optics , 4th ed. ( Pergamon, London , 1970 ), Chap. 10.

,5

5 . J. W. Goodman , Statistical Optics , 1st ed. ( Wiley, New York , 1985 ), Chap. 5.

]:

JrQrR=II(rS)exp[ik(rQrSrRrS)]rQrSrRrSdrS,
(2)

where II (r S) is the intensity distribution of the spatially incoherent source. The implication of this formal analogy between the formula for mutual intensity and that for the complex optical field reconstructed from a hologram with a phase-conjugated beam is the following. Referring to Fig. 1, if a hologram whose intensity transmittance II (r S) is proportional to the recorded intensity is illuminated with quasi-monochromatic spatially incoherent light with a temporal coherence length sufficiently larger than the longitudinal depth of the 3-D object, an optical field will be generated, for which the mutual intensity between observation point Q and reference point R is equal to the optical field that would be reconstructed if the hologram with the same amplitude transmittance IA (r S) = II (r S) were illuminated with a phase-conjugated version of the reference beam. Unlike conventional holography, the reconstructed coherence image is not directly observable. It can be visualized only as the contrast and the phase of an interference fringe pattern by using an appropriate interferometer. For this reason, we refer this technique as coherence holography to distinguish it from conventional holography. Just as a conventional computer-generated hologram (CGH) can create a three-dimensional image of a non-existing object, a computer-generated coherence hologram (CGCH) can create an optical field with a desired three-dimensional distribution of a spatial coherence function, which will open up a new possibility in the techniques for coherence control [6

6 . D. Courjon , J. Bulabois , and W. H. Carter , “ Use of a holographic filter to modify the coherence of a light field ,” J. Opt. Soc. Am. 71 , 469 – 473 ( 1981 ). [CrossRef]

,7

7 . D. Mendlovic , G. Shabtay , and A. W. Lohmann , “ Synthesis of spatial coherence ,” Opt. Lett. 26 , 361 – 363 ( 1999 ). [CrossRef]

].

When the hologram is illuminated with a partially coherent light with the complex degree of coherence μ(r S,r S′), the mutual intensity of the reconstructed field is given by [5

5 . J. W. Goodman , Statistical Optics , 1st ed. ( Wiley, New York , 1985 ), Chap. 5.

]

JrQrR=JrSrSexp[ik(rQrSrRrS)]rQrSrRrSdrSdrS,
(3)

where JrSrS=II(rS)II(rS)μrSrS is the mutual intensity of the field immediately behind the hologram, and II (r S) is the intensity transmittance of the hologram. If the spatial coherence is stationary and the field correlation length is shorter than the spatial structure of the hologram, then we can write J(r S,r S′)≈/II (r S)μr S), with Δr S =r S′ -r S. By changing the variable of integration, we can rewrite Eq. (3) as

JrQrR=μ(ΔrS){II(rS)exp[ik(rQrS(rRΔrS)rS)]rQrS(rRΔrS)rSdrS}d(ΔrS).
(4)

Noting that IA (r S)=II (r S) and substituting Eq. (1), we have

JrQrR=μ(ΔrS)u(rQ,rRΔrS)d(ΔrS),
(5)

which states that if the illumination is partially coherent, the coherence function reconstructed from the coherence hologram will be blurred, being convolved by the function μr S) of the complex degree of coherence. When the illumination is perfectly spatially incoherent, we have μr S)∝δr S), which gives J(r Q,r R)∝u(r Q,r R) so that recorded 3-D object is ideally reconstructed as the distribution of the mutual intensity.

3. Experiments

The reconstructed image encoded in the spatial coherence of the field cannot be observed directly. One could probe the coherence of the field with a Young’s double-pinhole setup, but this is a point-probing scheme that requires one to scan one of the pinholes over the 3-D space to probe the coherence of the field. We can simultaneously visualize the full-field distribution of the spatial coherence function as the contrast and the phase distribution of interference fringes by using an appropriate interferometer such as a wave-front-folding interferometer [16

16 . M. V. R. K. Murty , “ Interference between wavefronts rotated or reversed with respect to each other and its relation to spatial coherence ,” J. Opt. Soc. Am. 54 , 1187 – 1190 ( 1964 ). [CrossRef]

,17

17 . K. Itoh and Y. Ohtsuka , “ Fourier-transform spectral imaging: retrieval of source information from the three-dimensional spatial coherence ,” J. Opt. Soc. Am. A 3 , 94 – 100 ( 1986 ). [CrossRef]

] and a triangular interferometer with a double afocal system [10

10 . G. Cochran , “ New method of making Fresnel transforms ,” J. Opt. Soc. Am. 56 , 1513 – 1517 ( 1966 ). [CrossRef]

]. A Michelson interferometer was used in our actual experiment, but its function can be more conveniently explained with an equivalent Fizeau interferometer shown in Fig. 2. Because of the two plane parallel plates formed by the beam splitter and the mirror, each point source S on the incoherently illuminated hologram I(r S) produces an interference fringe pattern of a Fresnel zone plate (FZP) with its central axis normal to the beam splitter and passing through the source point S at r S. As the result of intensity-based super position of many FZPs weighted by the irradiance of the hologram, we observe interference fringe intensity at point P given by

IrΔzIS(rS){1+cos[k(Δzz)rrS2z+α(Δz)]}drS
=[IS(rS)drS]{1+μrΔzcos[α(Δz)βrΔz]},
(6)

where αz) is the initial phase of the FZP fringe, μ(rz) is a complex degree of coherence given by

μrΔz=μ(r,Δz)exp[iβ(r,Δz)]
=IS(rS)exp{ikΔzrrS2z2}drSIS(rS)drS.
(7)

It should be noted that the complex degree of coherence is given by the Fresnel transform of the incoherently illuminated hologram. If we record a Fresnel hologram with coherent light for an object at distance z¯ = z 2/2Δz from the hologram, and illuminate the hologram with spatially incoherent light from behind, we will observe on the beam splitter a set of interference fringe patterns whose fringe contrast and phase represent, respectively, the field amplitude and the phase of the original object recorded with coherent light.

Fig. 2. Direct visualization of a coherence image reconstructed from a coherence hologram. The coherence image is directly observable as the contrast and the phase of a fringe pattern.
Fig. 3. Special geometry for spatial coherence tomography and profilometry. A coherence hologram is placed in the front focal plane of a lens. Seen through the lens from the side of the interferometer, the hologram looks like an infinitely large hologram located at infinity.

Let us consider a special case of interest that opens up the possibility of spatial coherence tomography and profilometry [3

3 . J. Rosen and M. Takeda , “ Longitudinal spatial coherence applied for surface profilometry ,” Appl. Opt. 39 , 4107 – 4111 ( 2000 ). [CrossRef]

]. Equation (7) can be rewritten as

μ(r,Δz)=IS(r̂S)exp{ikΔztan2θrrSMaxr̂S2}dr̂SIS(r̂S)dr̂S,
(8)

where s = r s/r SMax is a position vector normalized with the size of the hologram r SMax, and tan θ = r SMax/z, with θ being the half angle subtended by the hologram as shown in Fig. 2. If the hologram is moved to infinity such that z → ∞ while keeping the angle θ constant, then r/r SMax in Eq. (8) becomes zero. This means that the spatial coherence function becomes independent of the lateral position r, and varies only in the longitudinal direction as a function of Δz, which enables longitudinal coherence sectioning by use of an appropriately tailored coherence function. This special optical geometry can be realized with the help of a positive lens. As shown in Fig. 3, the coherence hologram is placed in the front focal plane of the positive lens. Seen through the lens from the side of the interferometer, the virtual image of the hologram with a finite physical size r SMax = f tan θ looks like an infinitely large hologram with r Smax = ∞ located at infinity with a half angular size θ. By changing the computer-generated coherence hologram, one can control the longitudinal coherence function for the application to optical tomography and profilometry [3

3 . J. Rosen and M. Takeda , “ Longitudinal spatial coherence applied for surface profilometry ,” Appl. Opt. 39 , 4107 – 4111 ( 2000 ). [CrossRef]

].

Fig. 4. (a) Object; (b) Image reconstructed from phase-only hologram; (c) Modulus of spatial coherence function; (d) Coherence hologram representing spatially incoherent source distribution; (e) Coherence image visualized as a fringe contrast.

Shown in Fig. 4(a) is an object of letter H formed by 4x5 pixels. For this object, we generated a Fresnel hologram, with the parameters Δz = 1mm and tan θ = 0.15, as shown in Fig. 4(d), which is an on-axis phase-only hologram because of the limited spatial resolution and dynamic range of the liquid-crystal spatial light modulator (SLM) (CRL XGA2) used for the experiment. To see the effect of the phase-only reconstruction, we first reconstructed the hologram numerically with simulated coherent light. We found that the phase-only reconstruction causes the image to be blurred, as shown in Fig. 4(b). According to the proposed principle of coherence hologram, the brightness of this somewhat blurred image of the letter H will be transformed into the fringe visibility if the hologram is illuminated with spatially incoherent light. To prove this, we displayed the hologram on the SLM and illuminated it with an extended beam from a He-Ne laser through a rotating ground glass that destroys spatial coherence. Figure 4(e) shows a fringe pattern recorded with a Nikon Macro Lens, f=55mm, F2.8, mounted on a CCD camera Sony XC55, when Δz is adjusted to the design parameter of the hologram (Δz = 1mm). As predicted, the fringes exhibit a high contrast in the region that corresponds to the bright part of the numerically reconstructed image of Fig. 4(b). To see this more clearly, we analyzed the fringe pattern in Fig. 4(e) by the Fourier transform technique [18

18 . M. Takeda , H. Ina , and S. Kobayashi , “ Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry ,” J. Opt. Soc. Am. 72 , 156 – 160 ( 1982 ). [CrossRef]

], obtained the fringe contrast, and displayed it as a brightness distribution. As seen in Fig. 4(c), the contrast of the fringes observed in the image reconstructed from the incoherently illuminated coherence hologram has good correspondence to the brightness of the image numerically reconstructed from the coherently illuminated hologram.

4. Conclusions

In summary, we proposed the concept and the principle of an unconventional type of holography, which we called coherence holography. The unique feature of coherence holography is that, while an object is recorded with coherent light much in the same manner as in conventional holography, the recorded object is reconstructed as the 3-D distribution of a spatial coherence function from the hologram illuminated with spatially incoherent light. The computer-generated coherence hologram will opens up a new possibility for controlling the 3D coherence characteristics of the optical field. A simple optical geometry for direct visualization of the reconstructed coherence image was proposed and validated experimentally. Though we have presented the general principle of coherence holography, we also pointed out that the proposed principle includes the geometry of the hologram at infinity (realized with the help of a lens) as a special case, which can be applied to optical tomography and profilometry [3

3 . J. Rosen and M. Takeda , “ Longitudinal spatial coherence applied for surface profilometry ,” Appl. Opt. 39 , 4107 – 4111 ( 2000 ). [CrossRef]

]. To our knowledge, this is the first report on the general principle and the experimental demonstrations of coherence holography.

Acknowledgments

Part of this work was supported by Grant-in-Aid for JSPS Fellowship 15.52421 given to Wei Wang, and also by The 21st Century Center of Excellence (COE) Program on “Innovation of Coherent Optical Science” granted to The University of Electro-Communications, from Japanese Government.

References and links

1 .

D. Gabor , “ A new microscopic principle ,” Nature 161 , 777 – 778 ( 1948 ). [CrossRef] [PubMed]

2 .

E. N. Leith and J. Upatnieks , “ Reconstructed wavefronts and communication theory ,” J. Opt. Soc. Am. 52 , 1123 – 1130 ( 1962 ). [CrossRef]

3 .

J. Rosen and M. Takeda , “ Longitudinal spatial coherence applied for surface profilometry ,” Appl. Opt. 39 , 4107 – 4111 ( 2000 ). [CrossRef]

4 .

M. Born and E. Wolf , Principles of Optics , 4th ed. ( Pergamon, London , 1970 ), Chap. 10.

5 .

J. W. Goodman , Statistical Optics , 1st ed. ( Wiley, New York , 1985 ), Chap. 5.

6 .

D. Courjon , J. Bulabois , and W. H. Carter , “ Use of a holographic filter to modify the coherence of a light field ,” J. Opt. Soc. Am. 71 , 469 – 473 ( 1981 ). [CrossRef]

7 .

D. Mendlovic , G. Shabtay , and A. W. Lohmann , “ Synthesis of spatial coherence ,” Opt. Lett. 26 , 361 – 363 ( 1999 ). [CrossRef]

8 .

L. Mertz and N. O. Young , “Fresnel transformations of images,” in Proceedings of Conference on Optical Instruments and Techniques , K. J. Habell , ed. ( Chapman and Hall, London 1961 ) p.305.

9 .

A. W. Lohmann , “ Wavefront reconstruction for incoherent object ,” J. Opt. Soc. Am. 55 , 1555 – 1556 ( 1965 ). [CrossRef]

10 .

G. Cochran , “ New method of making Fresnel transforms ,” J. Opt. Soc. Am. 56 , 1513 – 1517 ( 1966 ). [CrossRef]

11 .

P. J. Peters , “ Incoherent holography with mercury light source ,” Appl. Phys. Lett. 8 , 209 – 210 ( 1966 ). [CrossRef]

12 .

H. R. Worthington Jr. , “ Production of holograms with incoherent illumination ,” J. Opt. Soc. Am. 56 , 1397 – 1398 ( 1966 ). [CrossRef]

13 .

W. H. Carter and E. Wolf , “ Correlation theory of wavefields generated by fluctuating three-dimensional, primary, scalar sources: I. General theory ,” Opt. Acta 28 , 227 – 244 ( 1981 ). [CrossRef]

14 .

J. Rosen and A. Yariv , “ General theorem of spatial coherence: application to three-dimensional imaging ,” J. Opt. Soc. Am. A 13 , 2091 – 2095 ( 1996 ). [CrossRef]

15 .

A. S. Marathay , “ Noncoherent-object hologram: its reconstruction and optical processing ,” J. Opt. Soc. Am. A 4 , 1861 – 1868 ( 1987 ). [CrossRef]

16 .

M. V. R. K. Murty , “ Interference between wavefronts rotated or reversed with respect to each other and its relation to spatial coherence ,” J. Opt. Soc. Am. 54 , 1187 – 1190 ( 1964 ). [CrossRef]

17 .

K. Itoh and Y. Ohtsuka , “ Fourier-transform spectral imaging: retrieval of source information from the three-dimensional spatial coherence ,” J. Opt. Soc. Am. A 3 , 94 – 100 ( 1986 ). [CrossRef]

18 .

M. Takeda , H. Ina , and S. Kobayashi , “ Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry ,” J. Opt. Soc. Am. 72 , 156 – 160 ( 1982 ). [CrossRef]

OCIS Codes
(030.1640) Coherence and statistical optics : Coherence
(090.0090) Holography : Holography
(100.3010) Image processing : Image reconstruction techniques
(110.4500) Imaging systems : Optical coherence tomography

ToC Category:
Research Papers

History
Original Manuscript: September 28, 2005
Revised Manuscript: November 8, 2005
Published: November 14, 2005

Citation
Mitsuo Takeda, Wei Wang, Zhihui Duan, and Yoko Miyamoto, "Coherence holography," Opt. Express 13, 9629-9635 (2005)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-13-23-9629


Sort:  Journal  |  Reset  

References

  1. D. Gabor, �??A new microscopic principle,�?? Nature 161, 777-778 (1948). [CrossRef] [PubMed]
  2. E. N. Leith and J. Upatnieks, �??Reconstructed wavefronts and communication theory,�?? J. Opt. Soc. Am. 52, 1123-1130 (1962). [CrossRef]
  3. J. Rosen and M. Takeda, �??Longitudinal spatial coherence applied for surface profilometry,�?? Appl. Opt. 39, 4107-4111 (2000). [CrossRef]
  4. M. Born and E. Wolf, Principles of Optics, 4th ed. (Pergamon, London, 1970), Chap. 10.
  5. J. W. Goodman, Statistical Optics, 1st ed. (Wiley, New York, 1985), Chap. 5.
  6. D. Courjon, J. Bulabois, and W. H. Carter, �??Use of a holographic filter to modify the coherence of a light field,�?? J. Opt. Soc. Am. 71, 469-473 (1981). [CrossRef]
  7. D. Mendlovic, G. Shabtay, A. W. Lohmann, �??Synthesis of spatial coherence,�?? Opt. Lett. 26, 361-363 (1999). [CrossRef]
  8. L. Mertz and N. O. Young, �??Fresnel transformations of images,�?? in Proceedings of Conference on Optical Instruments and Techniques, K. J. Habell, ed. (Chapman and Hall, London 1961) p.305.
  9. A. W. Lohmann, �??Wavefront reconstruction for incoherent object,�?? J. Opt. Soc. Am. 55, 1555-1556 (1965). [CrossRef]
  10. G. Cochran, �??New method of making Fresnel transforms,�?? J. Opt. Soc. Am. 56, 1513-1517 (1966). [CrossRef]
  11. P. J. Peters, �??Incoherent holography with mercury light source,�?? Appl. Phys. Lett. 8, 209-210 (1966). [CrossRef]
  12. H. R. Worthington, Jr., �??Production of holograms with incoherent illumination,�?? J. Opt. Soc. Am. 56, 1397-1398 (1966). [CrossRef]
  13. W. H. Carter and E. Wolf, �??Correlation theory of wavefields generated by fluctuating three-dimensional, primary, scalar sources: I. General theory,�?? Opt. Acta 28, 227-244 (1981). [CrossRef]
  14. J. Rosen and A. Yariv, �??General theorem of spatial coherence: application to three-dimensional imaging,�?? J. Opt. Soc. Am. A 13, 2091-2095 (1996). [CrossRef]
  15. A. S. Marathay, �??Noncoherent-object hologram: its reconstruction and optical processing,�?? J. Opt. Soc. Am. A 4, 1861-1868 (1987). [CrossRef]
  16. M. V. R. K. Murty, �??Interference between wavefronts rotated or reversed with respect to each other and its relation to spatial coherence,�?? J. Opt. Soc. Am. 54, 1187-1190 (1964). [CrossRef]
  17. K. Itoh and Y. Ohtsuka, �??Fourier-transform spectral imaging: retrieval of source information from the three-dimensional spatial coherence,�?? J. Opt. Soc. Am. A 3, 94-100 (1986). [CrossRef]
  18. M. Takeda, H. Ina and S. Kobayashi, �??Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry,�?? J. Opt. Soc. Am. 72, 156-160 (1982). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1. Fig. 2. Fig. 3.
 
Fig. 4.
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited