Zahid Yaqoob, Jigang Wu, Xiquan Cui, Xin Heng, and Changhuei Yang  »View Author Affiliations


Optics Express, Vol. 14, Issue 18, pp. 8127-8137 (2006)
http://dx.doi.org/10.1364/OE.14.008127


View Full Text Article

Acrobat PDF (166 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We demonstrate the use of shallow diffraction gratings for quadrature phase interferometry. A single shallow diffraction grating-based Michelson interferometer yields only trivial (0° or 180°) phase shift between different output ports. In comparison, a combination of two parallel shallow diffraction gratings can be useful to achieve desired phase shifts (e.g., 90° for quadrature phase interferometry). We show that the phase at different output ports of a grating-pair based interferometer can be adjusted by shearing the two gratings with respect to each other. Two harmonically-related diffraction gratings are used to demonstrate phase shift control at the output ports of a modified Michelson interferometer. Our experimental data is in good agreement with theory.

© 2006 Optical Society of America

1. Introduction

Highly accurate amplitude and phase measurements of optical signals are important in many applications ranging from metrology [1

1 . J. C. Shaw , “ Metrology using differential phase-contrast microscopy ,” Microelectron. Eng. 13 , 527 – 530 ( 1991 ). [CrossRef]

] to cell biology [2

2 . P. J. McMahon , E. D. Barone-Nugent , B. E. Allman , and K. A. Nugent , “ Quantitative phase-amplitude microscopy II: differential interference contrast imaging for biological TEM ,” J. Microsc.-Oxford 206 , 204 – 208 ( 2002 ). [CrossRef]

]. Traditional phase-contrast imaging techniques such as Zernike phase [3

3 . F. Zernike , “ Phase contrast, a new method for the microsopic observation of transparent objects ,” Physica 9 , 686 – 698 ( 1942 ). [CrossRef]

, 4

4 . F. Zernike , “ Phase contrast, a new method for the microscopic observation of transparent objects Part II ,” Physica 9 , 974 – 986 ( 1942 ). [CrossRef]

] and Nomarski differential interference contrast (DIC) [5

5 . G. Nomarski and A. R. Weill , “ Application à la métallographie des méthodes interférentielles à deux ondes polarisées ,” Rev. Metall. 2 , 121 – 128 ( 1955 ).

] render excellent phase contrast images; however, the phase information is only qualitative in nature. To retrieve quantitative phase information in Nomarski DIC, several approaches have been proposed that include: DIC with changing shear direction [6

6 . W. Shimada , T. Sato , and T. Yatagai , “ Optical surface microtopography using phase-shifting Nomarski microscope ,” Proc. SPIE 1332 , 525 – 529 ( 1990 ). [CrossRef]

], phase shifting DIC [7

7 . P. Hariharan and M. Roy , “ Achromatic phase-shifting for two-wavelength phase-stepping interferometry ,” Opt. Comm. 126 , 220 – 222 ( 1996 ). [CrossRef]

, 8

8 . C. J. Cogswell , N. I. Smith , K. G. Larkin , and P. Hariharan , “ Quantitative DIC microscopy using a geometric phase shifter ,” Proc. SPIE 2984 , 72 – 81 ( 1997 ). [CrossRef]

], and non-iterative phase reconstruction methods such as half-plane Hilbert transform [9

9 . M. R. Arnison , C. J. Cogswell , N. I. Smith , P. W. Fekete , and K. G. Larkin , “ Using the Hilbert transform for 3D visualization of differential interference contrast microscope images ,” J. of Microsc.-Oxford 199 , 79 – 84 ( 2000 ). [CrossRef]

]. In addition, Arnison et al. proposed a method that combined DIC microscopy with phase shifting, shear rotation, and Fourier phase integration to yield linear phase image of a sample [10

10 . M. R. Arnison , K. G. Larkin , C. J. R. Sheppard , N. I. Smith , and C. J. Cogswell , “ Linear phase imaging using differential interference contrast microscopy ,” J. of Microsc.-Oxford 214 , 7 – 12 ( 2004 ). [CrossRef]

]. Recently, Ishiwata et al. have developed retardation-modulated DIC - a method to extract the phase component from the DIC image using two images with different retardation [11

11 . H. Ishiwata , M. Itoh , and T. Yatagai , “ A new method of three-dimensional measurement by differential interference contrast microscope ,” Opt. Comm. 260 , 117 – 126 ( 2006 ). [CrossRef]

].

Other methods for quantitative phase imaging (QPI) include digital holography [12

12 . U. Schnars and W. Juptner , “ Direct Recording of Holograms by a Ccd Target and Numerical Reconstruction ,” Appl. Opt. 33 , 179 – 181 ( 1994 ). [CrossRef] [PubMed]

, 13

13 . E. Cuche , F. Bevilacqua , and C. Depeursinge , “ Digital holography for quantitative phase-contrast imaging ,” Opt. Lett. 24 , 291 – 293 ( 1999 ). [CrossRef]

], Hilbert phase microscopy (HPM) [14

14 . G. Popescu , T. Ikeda , C. A. Best , K. Badizadegan , R. R. Dasari , and M. S. Feld , “ Erythrocyte structure and dynamics quantified by Hilbert phase microscopy ,” J. Biomed. Opt. 10 , ( 2005 ). [CrossRef]

, 15

15 . T. Ikeda , G. Popescu , R. R. Dasari , and M. S. Feld , “ Hilbert phase microscopy for investigating fast dynamics in transparent systems ,” Opt. Lett. 30 , 1165 – 1167 ( 2005 ). [CrossRef] [PubMed]

], and polarization based techniques [16

16 . D. S. Marx and D. Psaltis , “ Polarization quadrature measurement of subwavelength diffracting structures ,” Appl. Opt. 36 , 6434 – 6440 ( 1997 ). [CrossRef]

, 17

17 . D. O. Hogenboom , C. A. DiMarzio , T. J. Gaudette , A. J. Devaney , and S. C. Lindberg , “ Three-dimensional images generated by quadrature interferometry ,” Opt. Lett. 23 , 783 – 785 ( 1998 ). [CrossRef]

]. Interference microscopy techniques based on PSI generally require recording of four interferograms with precise π/2 phase shifts of the reference field, adding complexity to the system while others can be computation extensive. HPM and digital holography are simpler as they require only one interferogram for QPI. We note that the methods depend on recording of high frequency spatial fringes for successful phase unwrapping. We also note that multiport fiber based systems such as 3×3 couplers can provide non-trivial phase difference, which can be manipulated for quadrature phase measurements [18

18 . M. A. Choma , “ Instantaneous quadrature low-coherence interferometry with 3 × 3 fiber-optic couplers ,” Opt. Lett. 28 , 2162 – 2164 ( 2003 ). [CrossRef] [PubMed]

, 19

19 . Z. Yaqoob , J. Fingler , X. Heng , and C. H. Yang , “ Homodyne en face optical coherence tomography ,” Opt. Lett. 31 , 1815 – 1817 ( 2006 ). [CrossRef] [PubMed]

]. However, free space equivalents of a 3×3 coupler do not exist.

This reported method to obtain non-trivial phase shift opens new possibilities for full-field quadrature phase interferometry.

2. Phase of diffracted light in shallow gratings

The phase of transmitted/reflected and diffracted light in shallow diffraction gratings is a well understood quantity. However, for the sake of completeness, we provide a brief account of how a diffraction grating affects the phase of light. Consider a sinusoidal phase grating (see Fig. 1).

Fig. 1. Spatial phase modulation in a sinusoidal phase grating.

The complex transmittance of a sinusoidal phase grating can be expressed as:

t(x)=exp{cos(2πΛ(x+xo))},
(1)

where α, Λ, and xo are the amplitude of phase modulation, period, and displacement from the origin along x-direction, respectively, of the phase grating. Defining ξ(xo ) = 2πxo /Λ, we can rewrite Eq. (1) in the form:

t(x)=m=Jm(α)exp{jm(2πΛx+ξ(xo)+π2)},
(2)

where Jm (α) is m th order Bessel function of the first kind. Using the identity J -m(α) = (-1)m Jm (α), the relative phase of the m th diffracted order with respect to the zeroth order is given by:

ϕ(xo)={m{ξ(xo)+π2},m1m{ξ(xo)+π2}.m1
(3)

It should be noted that for shallow phase gratings, Eq. (3) holds regardless of the grating profile [24

24 . C. M. B. Cordeiro , L. Cescato , A. A. Freschi , and L. F. Li , “ Measurement of phase differences between the diffracted orders of deep relief gratings ,” Opt. Lett. 28 , 683 – 685 ( 2003 ). [CrossRef] [PubMed]

].

3. Single grating-based Michelson interferometer

In the arrangement shown in Fig. 2(a), a collimated beam from a laser source is directed at normal incidence at G1, which acts as a beam splitter during the first diffraction. Only two beams are considered, i.e., the zeroth order (black line) and a first order diffracted beam (red line) which form the sample and reference arms, respectively, of the Michelson interferometer. Note that the grating period Λ1 can be chosen so that only the zeroth and the first order diffracted beams exist. Mirror M1 is shown as the sample whereas M2 represents the reference mirror. The returning sample and reference beams reach the grating G1 and undergo a second diffraction. At this time, the grating acts both as a beam splitter as well as a combiner, since it splits and combines the incoming sample and reference beams at the three output ports I, II, and III of the interferometer. The coincident reference and sample beams at the three ports are shown as dashed black and red lines [see Fig. 2(b)]. A beam splitter (BS) is used to separate the output beam at port II from the input beam. In the context of Figs. 2(c)–2(e), which illustrate the phase of the diffracted beams with respect to the undiffracted beams during the two passes, the total electric field at port I of the single grating-based interferometer can be written as:

EI=E1exp{i(2kd1ξ1(x1)+π2)}Field comp. from the sample arm
+E2exp{i(2kd2+ξ1(x1)+π2)},Field comp. from the reference arm
(4)

where E 1 and E 2 are the amplitudes of the field components reaching port I from the sample and reference arms, respectively. k is the optical wave vector, and the parameters d 1 and d 2 correspond to the path lengths of the sample and reference arms, respectively. Moreover, ξ 1(x 1) = 2πx 11, where x 1 is the displacement of the grating G1. Therefore, using E I EI*, the interference signal at port I of the interferometer can be written as:

iI=2A1cos{2k(d2d1)+2ξ1(x1)},
(5a)
Fig. 2. (a, b) Schematic of a Michelson interferometer using a single shallow diffraction grating, G1. (a) The transmitted sample beam and the diffracted reference beam are shown in black and red solid lines, respectively. (b) shows dashed black and red lines representative of coincident sample and reference beam at output ports I, II, and III of the interferometer. (c) Phase shift of the diffracted beam with respect to the undiffracted beam during the first diffraction. (d,e) Phase shifts of the diffracted sample and reference beams, respectively, during the second diffraction. x 1 is the actuation of grating G1 along the x-direction for the experiment, whereas d 1 and d 2 represent path lengths of sample and reference arms, respectively. M i : ith Mirror; BS: Beam splitter.

Similarly, the interference signals at ports II and III of the interferometer can be written as:

iII=2A2cos{2k(d2d1)+2ξ1(x1)+π},
(5b)
iIII=2A3cos{2k(d2d1)+2ξ1(x1)+π},
(5c)

respectively. The parameters Ai , i = 1, 2, 3 are the amplitudes of the interference signals at ports I, II, and III, respectively, and depend upon the diffraction efficiency of the grating G1. It is clear from Eq. (5) that ports II and III of a single shallow grating-based Michelson interferometer are in phase whereas the port I of the interferometer is 180° out of phase with respect to the other two output ports. This geometry is therefore unsuitable for extracting quadrature signals.

To corroborate the above discussion, an experimental setup was made using a collimated beam (1/e2 diameter ≈ 1 mm) from a HeNe laser (λ = 633 nm) and a shallow 600 grooves/mm blazed transmission grating (Thorlabs, Inc., GT25-06V). The reference mirror was mounted on a voice coil to modulate the reference arm. Heterodyne interference signals were acquired at the three output ports using New Focus photodetectors (model 2001) and a 16-bit analog-to-digital converter (National Instruments, model PXI-6120). The grating was mounted on a computer-controlled piezo actuator (25.5 nm/V) in order to measure the phase shifts between different ports of the interferometer for various positions of the grating. For each position of the grating, DC components were removed from the acquired heterodyne signals at the three ports; the resulting interference signals, represented by Eqs. (5a)–(5c), were subsequently processed to determine the phase shifts between the output ports. Figure 3 shows the measured phase shifts between different output ports of the interferometer versus grating displacement over 3.5 microns (~ 2 grating periods) along the x 1 direction specified in Figs. 2(a), and 2(b). As expected, ports II and III are in phase whereas port I is ~180° out of phase with respect to the ports II and III, indicating that a single shallow diffraction grating-based Michelson interferometer cannot provide but trivial phase shifts between different output ports. Although, p-polarized light was used in this reported experiment (see results in Fig. 3), similar results were observed for the s-polarized light.

Fig. 3. Measured phase shifts between different ports of a single grating-based Michelson interferometer versus grating displacement (x 1) along the x-direction.

4. Harmonically-related grating pair-based Michelson interferometer

As illustrated by Eq. (5a)–Eq. (5c), a non-trivial phase shift given by 2ξ 1 (x 1) is conferred on the interference term associated with each output port of a single-grating based interferometer. Since the amount of non-trivial phase shift is the same for each output port, the configuration shown in Figs. 2(a) and 2(b) yields only trivial phase difference between the output ports. This illustrates that it is not possible for a single shallow grating based interferometer, the Michelson interferometer described above or the Mach Zehnder configuration described in Ref. [24

24 . C. M. B. Cordeiro , L. Cescato , A. A. Freschi , and L. F. Li , “ Measurement of phase differences between the diffracted orders of deep relief gratings ,” Opt. Lett. 28 , 683 – 685 ( 2003 ). [CrossRef] [PubMed]

], to operate as a quadrature phase interferometer.

We choose the period of first grating G1 as twice the period of the second grating G2. The two gratings are placed at distance d 1 and aligned such that the grating planes as well as grating vectors are parallel to that of each other. Two mirrors M1 and M2 are introduced in the setup and aligned such that the first order diffracted beams (solid green and red lines) from G1 meet with the undiffracted beam (solid black line) at G2 [see Fig. 4(a)]. Moreover, the angle of incidence for the two beams at G2 is the same as the angle of diffraction θ at G1.

Fig. 4. (a, b). Modified Michelson interferometer design based on two harmonically-related shallow transmission gratings, where d 1 is the inter-grating distance and θ is the angle of diffraction. The sample and reference beams are shown as solid black and dashed red-green lines, respectively. (c)-(h) Phase shifts of the diffracted and undiffracted light during the first and second diffractions at gratings G1 and G2. Parameters x 1 and x 2 correspond to the actuations of grating G1 and G2, respectively, whereas d 3 and d 4 represent the path lengths of the sample and reference arms, respectively. M i : ith Mirror; BS: Beam splitter.

For a given inter-grating distance d 1, the two first order diffracted beams will travel the same distance d 2 = d 1/cos(θ) between G1 and G2. The grating G2 combines the two first order beams from G1 to form the reference beam (dashed red-green line) as shown in Fig. 4(a). The undiffracted beam from G1 passes straight through G2 to form the sample arm of the interferometer.

We note that fine alignment between the grating vectors is important in the proposed scheme for non–trivial phase shifts. The grating vectors alignment can be ensured by observing the interference pattern of reference beam arriving at mirror M4. As mentioned earlier, the reference beam (represented by dashed red-green line) is comprised of two field components. Without proper alignment of the grating vectors, the interference of the two field components will form fringes at mirror M4. However, by adjusting the grating vector alignment of the grating G2, the fringes can be transformed into a bull’s eye pattern – a representative of exact alignment of the grating vectors.

EI=exp{i2k(d2+d4)}
×[EI,1exp{i(ξ1(x1)+π2)}Field comp. from ref. arm viaM1,M4,M1
+EI,2exp{i(ξ1(x1)ξ2(x2)+2π)}Field comp. from ref. arm viaM1,M4,M2
+EI,3exp{i(ξ1(x1)ξ2(x2)+π)}Field comp. from ref. arm viaM2,M4,M1
+EI,4exp{i(3ξ1(x1)2ξ2(x2)+π2)}]Field comp. from ref. arm viaM2,M4,M2
+EI,5exp{i2k(d1+d3)}exp{i(ξ1(x1)+π2)}Field comp. from the sample arm
(6)

As labeled in Eq. (6), the first four terms represent the field components arriving at the output port I from the reference arm. This is because there are two possible paths (via mirrors M1 and M2) to transit between gratings G1 and G2. The 5th term in Eq. (6) is the field component contributed by the sample arm. We also note that by shearing the grating G2 with respect to G1, the phase of 2nd to 4th reference field components can be adjusted. As a note, if either of the paths (via mirrors M1 and M2) were blocked, only 1st or 4th term will remain (as contribution from the reference arm) that will yield trivial phase shifts similar to that in a single grating-based interferometer design.

From Eq. (6), we can express the interference signal at the output port I of the interferometer [shown in Fig. 4(a), and 4(b)] can be written as:

iI(x1,x2)=2E(x1,x2)EI,5cos[2k(d4d3+d2d1)+ϕ(x1,x2)2{ξ2(x2)+ξ1(x1)}],
(7a)

where

E(x1,x2)=F12(x1,x2)+F22(x1,x2),ϕ(x1,x2)=tan1[F2(x1,x2)F1(x1,x2)]
(7b)

such that

F1(x1,x2)=EI,1cos{4ξ1(x1)+2ξ2(x2)}+(EI,2EI,3)sin{2ξ1(x1)+ξ2(x2)}+EI,4,
(7c)
F2(x1,x2)=EI,1sin{4ξ1(x1)+2ξ2(x2)}(EI,2+EI,3)cos{2ξ1(x1)+ξ2(x2)}.
(7d)

The amplitudes of the field components can be written in terms of diffraction efficiencies of the gratings G1 and G2 as:

EI,1=η1,24η2,43η2,34η1,43,
(8a)
EI,2=η1,24η2,43η2,36η1,63,
(8b)
EI,3=η1,26η2,63η2,34η1,43,
(8c)
EI,4=η1,26η2,63η2,36η1,63,
(8d)
EI,5=η1,25η2,52η2,25η1,53,
(8e)

where η i, mn is the diffraction efficiency of ith grating from port m to n (see Fig. 5 that labels different ports of the gratings G1 and G2).

Fig. 5. Schematics labeling different ports of gratings G1 and G2.

Similarly, the interference signal at port II of the interferometer can be expressed as:

iII(x1,x2)=2E(x1,x2)EII,5cos[2k(d4d3+d2d1)+ϕ(x1,x2)2{ξ2(x2)+ξ1(x1)}],
(9a)

where

E(x1,x2)=F32(x1,x2)+F42(x1,x2),ϕ(x1,x2)=tan1[F4(x1,x2)F3(x1,x2)]
(9b)

such that

F3(x1,x2)=EII,1cos{4ξ1(x1)+2ξ2(x2)}+(EII,2+EII,3)sin{2ξ1(x1)+ξ2(x2)}+EII,4,
(9c)
F4(x1,x2)=EII,1sin{4ξ1(x1)+2ξ2(x2)}(EII,2+EII,3)cos{2ξ1(x1)+ξ2(x2)}.
(9d)

In Eqs. (9a)–(9d), E II,1 to E II,4 represent the amplitudes of field components from the reference arm whereas E II,5 is the amplitude of the field component from the sample arm arriving at port II of the interferometer, which are given in terms of diffraction efficiencies of the gratings G1 and G2 as:

EII,1=η1,24η2,43η2,34η1,42,
(10a)
EII,2=η1,24η2,43η2,36η1,62,
(10b)
EII,3=η1,26η2,63η2,34η1,42,
(10c)
EII,4=η1,26η2,63η2,36η1,62,
(10d)
EII,5=η1,25η2,52η2,25η1,52.
(10e)

In a similar fashion, the interference signal at port III of the interferometer is written as:

iIII(x1,x2)=2E(x1,x2)EIII,5cos[2k(d4d3+d2d1)+ϕ(x1,x2)2{ξ2(x2)+ξ1(x1)}+π],
(11a)

where

E(x1,x2)=F52(x1,x2)+F62(x1,x2),ϕ(x1,x2)=tan1[F6(x1,x2)F5(x1,x2)]
(11b)

such that

F5(x1,x2)=EIII,1cos{4ξ1(x1)+2ξ2(x2)}+(EIII,2EIII,3)sin{2ξ1(x1)+ξ2(x2)}+EIII,4,
(11c)
F6(x1,x2)=EIII,1sin{4ξ1(x1)+2ξ2(x2)}+(EIII,3EIII,2)cos{2ξ1(x1)+ξ2(x2)}.
(11d)

In Eqs. (11a)–(11d), E III,1 to E III,4 correspond to the amplitudes of field components from the reference arm whereas E III,5 denotes the amplitude of the field component from the sample arm arriving at port III of the interferometer. In terms of the diffraction efficiencies of the gratings G1 and G2, the amplitudes of above mentioned field components are given by:

EIII,1=η1,24η2,43η2,34η1,41,
(12a)
EIII,2=η1,24η2,43η2,36η1,61,
(12b)
EIII,3=η1,26η2,63η2,34η1,41,
(12c)
EIII,4=η1,26η2,63η2,36η1,61,
(12d)
EIII,5=η1,25η2,52η2,25η1,51.
(12e)

It can be seen from Eqs. (7)–(12) that the amplitude and phase of the interference signals at the three ports I, II, and III not only depend on the strength of individual field components taking part in the interference but also on the additional phase shifts from gratings G1 and G2.

Fig. 6. Measured phase shifts between (a) ports I & II and (b) ports I & III of a harmonically-related gratings based modified Michelson interferometer versus shearing of grating G2 with respect to G1. The locations where phase difference between port I and III are equal 90° and 270° are labeled.

The only phase term that involves the path lengths di , i = 1, 2, 3, 4 is 2k(d 4-d 3+d 2-d 1), and is common to all the three interference signals. As such, it yields only a trivial phase between different output ports. This also illustrates that in the described scheme, the shearing of the gratings to achieve non-trivial phase does not change the path length relationship between the interference beams at the output ports of the modified Michelson interferometer.

For experimental verification, we realized a setup shown in Figs. 4(a), and 4(b). A collimated beam (1/e2 diameter ≈ 1 mm) from a 633 nm HeNe laser was used in the experiment. We chose G1 to be the same as that used in the setup shown in Fig. 2(a) whereas G2 – the second harmonic grating was selected as 1200 grooves/mm blazed transmission grating (Thorlabs, Inc., GT25-12). The path length d 1 between the gratings G1 and G2 was ~20 cm. The reference mirror M4 was mounted on a voice coil to modulate the reference arm. The grating G2 was translated along the x-direction using a piezo actuator (25.5 nm/V) and heterodyne interference signals were acquired at the three output ports using the same photodetectors as used in our earlier experimental study.

Table 1. Measured efficiencies of the gratings used in the setup shown in Figs. 4(a), and 4(b). These diffraction efficiencies were used to determine the theoretical phase shifts between different output ports of the modified Michelson interferometer.

table-icon
View This Table

Figure 6 shows both the measured as well as the theoretical phase differences between output ports of the interferometer versus shearing of grating G2 up to one grating periods. Table 1 shows measured diffraction efficiencies of gratings G1 and G2 (used in the setup) to calculate theoretical phase shifts between different ports of the interferometer. It can be seen that phase shift between ports I and III changes almost in a linear fashion as the grating G2 is sheared along the x 2 direction. This ability to achieve non-trivial phase shifts illustrates the possibility to design gratings-based interferometer for full-field quadrature phase interferometry.

5. Summary and conclusion

In summary, we have proposed and experimentally demonstrated the use of planar shallow diffraction gratings in a modified Michelson interferometric setup to achieve non-trivial phase shifts between different output ports. The phase shift is adjusted by simply shearing the gratings with respect to each other. The ability to adjust the phase shifts between different ports of the interferometer is a useful feature of the design for quadrature phase interferometry. The main advantage of the proposed method for non-trivial phase is that the shearing of the gratings does not change the path length relationship between interference beams at the output ports of the interferometer – an advantage for metrology and low coherence interferometry applications. Note that a single shallow diffraction grating-based Michelson interferometer cannot provide but trivial phase shifts between different output ports; hence, it is not suitable for quadrature phase measurements.

Acknowledgment

The authors acknowledge helpful discussions with Demetri Psaltis and Marinko Sarunic. This work is supported by NSF career award BES-0547657.

References and links

1 .

J. C. Shaw , “ Metrology using differential phase-contrast microscopy ,” Microelectron. Eng. 13 , 527 – 530 ( 1991 ). [CrossRef]

2 .

P. J. McMahon , E. D. Barone-Nugent , B. E. Allman , and K. A. Nugent , “ Quantitative phase-amplitude microscopy II: differential interference contrast imaging for biological TEM ,” J. Microsc.-Oxford 206 , 204 – 208 ( 2002 ). [CrossRef]

3 .

F. Zernike , “ Phase contrast, a new method for the microsopic observation of transparent objects ,” Physica 9 , 686 – 698 ( 1942 ). [CrossRef]

4 .

F. Zernike , “ Phase contrast, a new method for the microscopic observation of transparent objects Part II ,” Physica 9 , 974 – 986 ( 1942 ). [CrossRef]

5 .

G. Nomarski and A. R. Weill , “ Application à la métallographie des méthodes interférentielles à deux ondes polarisées ,” Rev. Metall. 2 , 121 – 128 ( 1955 ).

6 .

W. Shimada , T. Sato , and T. Yatagai , “ Optical surface microtopography using phase-shifting Nomarski microscope ,” Proc. SPIE 1332 , 525 – 529 ( 1990 ). [CrossRef]

7 .

P. Hariharan and M. Roy , “ Achromatic phase-shifting for two-wavelength phase-stepping interferometry ,” Opt. Comm. 126 , 220 – 222 ( 1996 ). [CrossRef]

8 .

C. J. Cogswell , N. I. Smith , K. G. Larkin , and P. Hariharan , “ Quantitative DIC microscopy using a geometric phase shifter ,” Proc. SPIE 2984 , 72 – 81 ( 1997 ). [CrossRef]

9 .

M. R. Arnison , C. J. Cogswell , N. I. Smith , P. W. Fekete , and K. G. Larkin , “ Using the Hilbert transform for 3D visualization of differential interference contrast microscope images ,” J. of Microsc.-Oxford 199 , 79 – 84 ( 2000 ). [CrossRef]

10 .

M. R. Arnison , K. G. Larkin , C. J. R. Sheppard , N. I. Smith , and C. J. Cogswell , “ Linear phase imaging using differential interference contrast microscopy ,” J. of Microsc.-Oxford 214 , 7 – 12 ( 2004 ). [CrossRef]

11 .

H. Ishiwata , M. Itoh , and T. Yatagai , “ A new method of three-dimensional measurement by differential interference contrast microscope ,” Opt. Comm. 260 , 117 – 126 ( 2006 ). [CrossRef]

12 .

U. Schnars and W. Juptner , “ Direct Recording of Holograms by a Ccd Target and Numerical Reconstruction ,” Appl. Opt. 33 , 179 – 181 ( 1994 ). [CrossRef] [PubMed]

13 .

E. Cuche , F. Bevilacqua , and C. Depeursinge , “ Digital holography for quantitative phase-contrast imaging ,” Opt. Lett. 24 , 291 – 293 ( 1999 ). [CrossRef]

14 .

G. Popescu , T. Ikeda , C. A. Best , K. Badizadegan , R. R. Dasari , and M. S. Feld , “ Erythrocyte structure and dynamics quantified by Hilbert phase microscopy ,” J. Biomed. Opt. 10 , ( 2005 ). [CrossRef]

15 .

T. Ikeda , G. Popescu , R. R. Dasari , and M. S. Feld , “ Hilbert phase microscopy for investigating fast dynamics in transparent systems ,” Opt. Lett. 30 , 1165 – 1167 ( 2005 ). [CrossRef] [PubMed]

16 .

D. S. Marx and D. Psaltis , “ Polarization quadrature measurement of subwavelength diffracting structures ,” Appl. Opt. 36 , 6434 – 6440 ( 1997 ). [CrossRef]

17 .

D. O. Hogenboom , C. A. DiMarzio , T. J. Gaudette , A. J. Devaney , and S. C. Lindberg , “ Three-dimensional images generated by quadrature interferometry ,” Opt. Lett. 23 , 783 – 785 ( 1998 ). [CrossRef]

18 .

M. A. Choma , “ Instantaneous quadrature low-coherence interferometry with 3 × 3 fiber-optic couplers ,” Opt. Lett. 28 , 2162 – 2164 ( 2003 ). [CrossRef] [PubMed]

19 .

Z. Yaqoob , J. Fingler , X. Heng , and C. H. Yang , “ Homodyne en face optical coherence tomography ,” Opt. Lett. 31 , 1815 – 1817 ( 2006 ). [CrossRef] [PubMed]

20 .

B. L. Danielson and C. Y. Boisrobert , “ Absolute optical ranging using low coherence interferometry ,” Appl. Opt. 30 , 2975 – 2979 ( 1991 ). [CrossRef] [PubMed]

21 .

V. V. Tuchin , “ Coherence-domain methods in tissue and cell optics ,” Laser Phys. 8 , 807 – 849 ( 1998 ).

22 .

S. R. Thurber , A. M. Brodsky , and L. W. Burgess , “ Characterization of random media by low-coherence interferometry ,” Appl. Spectrosc. 54 , 1506 – 1514 ( 2000 ). [CrossRef]

23 .

D. Huang , E. A. Swanson , C. P. Lin , J. S. Schuman , W. G. Stinson , W. Chang , M. R. Hee , T. Flotte , K. Gregory , C. A. Puliafito , and J. G. Fujimoto , “ Optical coherence tomography ,” Science 254 , 1178 – 1181 ( 1991 ). [CrossRef] [PubMed]

24 .

C. M. B. Cordeiro , L. Cescato , A. A. Freschi , and L. F. Li , “ Measurement of phase differences between the diffracted orders of deep relief gratings ,” Opt. Lett. 28 , 683 – 685 ( 2003 ). [CrossRef] [PubMed]

OCIS Codes
(120.2880) Instrumentation, measurement, and metrology : Holographic interferometry
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(180.3170) Microscopy : Interference microscopy

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: June 28, 2006
Revised Manuscript: August 15, 2006
Manuscript Accepted: August 17, 2006
Published: September 1, 2006

Virtual Issues
Vol. 1, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Zahid Yaqoob, Jigang Wu, Xiquan Cui, Xin Heng, and Changhuei Yang, "Harmonically-related diffraction gratings-based interferometer for quadrature phase measurements," Opt. Express 14, 8127-8137 (2006)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-18-8127


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. C. Shaw, "Metrology using differential phase-contrast microscopy," Microelectron. Eng. 13, 527-530 (1991). [CrossRef]
  2. P. J. McMahon, E. D. Barone-Nugent, B. E. Allman, and K. A. Nugent, "Quantitative phase-amplitude microscopy II: differential interference contrast imaging for biological TEM," J. Microsc.-Oxford 206, 204-208 (2002). [CrossRef]
  3. F. Zernike, "Phase contrast, a new method for the microsopic observation of transparent objects," Physica 9, 686-698 (1942). [CrossRef]
  4. F. Zernike, "Phase contrast, a new method for the microscopic observation of transparent objects Part II," Physica 9, 974-986 (1942). [CrossRef]
  5. G. Nomarski, and A. R. Weill, "Application à la métallographie des méthodes interférentielles à deux ondes polarisées," Rev. Metall. 2, 121-128 (1955).
  6. W. Shimada, T. Sato, and T. Yatagai, "Optical surface microtopography using phase-shifting Nomarski microscope," Proc. SPIE 1332, 525-529 (1990). [CrossRef]
  7. P. Hariharan, and M. Roy, "Achromatic phase-shifting for two-wavelength phase-stepping interferometry," Opt. Comm. 126, 220-222 (1996). [CrossRef]
  8. C. J. Cogswell, N. I. Smith, K. G. Larkin, and P. Hariharan, "Quantitative DIC microscopy using a geometric phase shifter," Proc. SPIE 2984, 72-81 (1997). [CrossRef]
  9. M. R. Arnison, C. J. Cogswell, N. I. Smith, P. W. Fekete, and K. G. Larkin, "Using the Hilbert transform for 3D visualization of differential interference contrast microscope images," J. of Microsc.-Oxford 199, 79-84 (2000). [CrossRef]
  10. M. R. Arnison, K. G. Larkin, C. J. R. Sheppard, N. I. Smith, and C. J. Cogswell, "Linear phase imaging using differential interference contrast microscopy," J. of Microsc.-Oxford 214, 7-12 (2004). [CrossRef]
  11. H. Ishiwata, M. Itoh, and T. Yatagai, "A new method of three-dimensional measurement by differential interference contrast microscope," Opt. Comm. 260, 117-126 (2006). [CrossRef]
  12. U. Schnars, and W. Juptner, "Direct Recording of Holograms by a Ccd Target and Numerical Reconstruction," Appl. Opt. 33, 179-181 (1994). [CrossRef] [PubMed]
  13. E. Cuche, F. Bevilacqua, and C. Depeursinge, "Digital holography for quantitative phase-contrast imaging," Opt. Lett. 24, 291-293 (1999). [CrossRef]
  14. G. Popescu, T. Ikeda, C. A. Best, K. Badizadegan, R. R. Dasari, and M. S. Feld, "Erythrocyte structure and dynamics quantified by Hilbert phase microscopy," J. Biomed. Opt. 10, (2005). [CrossRef]
  15. T. Ikeda, G. Popescu, R. R. Dasari, and M. S. Feld, "Hilbert phase microscopy for investigating fast dynamics in transparent systems," Opt. Lett. 30, 1165-1167 (2005). [CrossRef] [PubMed]
  16. D. S. Marx, and D. Psaltis, "Polarization quadrature measurement of subwavelength diffracting structures," Appl. Opt. 36, 6434-6440 (1997). [CrossRef]
  17. D. O. Hogenboom, C. A. DiMarzio, T. J. Gaudette, A. J. Devaney, and S. C. Lindberg, "Three-dimensional images generated by quadrature interferometry," Opt. Lett. 23, 783-785 (1998). [CrossRef]
  18. M. A. Choma, "Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers," Opt. Lett. 28, 2162 - 2164 (2003). [CrossRef] [PubMed]
  19. Z. Yaqoob, J. Fingler, X. Heng, and C. H. Yang, "Homodyne en face optical coherence tomography," Opt. Lett. 31, 1815-1817 (2006). [CrossRef] [PubMed]
  20. B. L. Danielson, and C. Y. Boisrobert, "Absolute optical ranging using low coherence interferometry," Appl. Opt. 30, 2975-2979 (1991). [CrossRef] [PubMed]
  21. V. V. Tuchin, "Coherence-domain methods in tissue and cell optics," Laser Phys. 8, 807-849 (1998).
  22. S. R. Thurber, A. M. Brodsky, and L. W. Burgess, "Characterization of random media by low-coherence interferometry," Appl. Spectrosc. 54, 1506-1514 (2000). [CrossRef]
  23. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, "Optical coherence tomography," Science 254, 1178-1181 (1991). [CrossRef] [PubMed]
  24. C. M. B. Cordeiro, L. Cescato, A. A. Freschi, and L. F. Li, "Measurement of phase differences between the diffracted orders of deep relief gratings," Opt. Lett. 28, 683-685 (2003). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.