Thin-film thickness profile and its refractive index measurements by dispersive white-light interferometry

Young-Sik Ghim and Seung-Woo Kim  »View Author Affiliations


Optics Express, Vol. 14, Issue 24, pp. 11885-11891 (2006)
http://dx.doi.org/10.1364/OE.14.011885


View Full Text Article

Acrobat PDF (466 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

As an extension of the authors’ previous report of Ref 1, we describe an improved version of dispersive white-light interferometry that enables us to measure the tomographical thickness profile of a thin-film layer through Fourier-transform analysis of spectrally-resolved interference signals. The group refractive index can also be determined without prior knowledge of the geometrical thickness of the film layer. Owing to fast measurement speed with no need of mechanical depth scanning, the proposed method is well suited for in-line 3-D inspection of dielectric thinfilm layers particularly for the semiconductor and flat-panel display industry.

© 2006 Optical Society of America

1. Introduction

White-light interferometry allows us to produce spectrally-resolved interference for a variety of applications including the 3-D surface profile measurement as concerned in this investigation. A long-established way of implementing white-light interferometry is to use a mechanical scanner so as to vary the optical path difference between the measurement and reference arms while monitoring the resulting interferograms. [2

2. P. De Groot and L. Deck, “Three-dimensional imaging by sub-Nyquist sampling of white-light interferograms,” Opt. Lett. 18, 1462–1464 (1993). [CrossRef] [PubMed]

] This technique is termed the z-scanning; z represents the optical path difference. The other way, which may be called the k-scanning with k being the wave number, involves sweeping the wavelength of illumination light progressively by use of a tunable laser, [3

3. S. Kuwamura and I. Yamaguchi, “Wavelength scanning profilometry for real-time surface shape measurement,” Appl. Opt. 36, 4473–4482 (1997). [CrossRef] [PubMed]

] acousto-optical modulator, [4

4. D. S. Mehta, S. Saito, H. Hinosugi, M. Takeda, and T. Kurosawa, “Spectral interference mirau microscope with an acousto-optic tunable filter for three-dimensional surface profilometry,” Appl. Opt. 42, 1296–1305 (2003). [CrossRef] [PubMed]

] and liquid crystal cavity. [5

5. M. Kinoshita, M. Takeda, H. Yago, Y. Watanabe, and T. Kurokawa, “Optical frequency-domain imaging microprofilometry with a frequency-tunable liquid-crystal Fabry-Perot etalon device,” Appl. Opt. 38, 7063–7068 (1999). [CrossRef]

] This k-scanning offers the advantage of fast measurement with no need of a mechanical scanner in comparison to the z- scanning, but its performance is restricted by the narrowly-limited wavelength range of tunable sources available in practice. The k-scanning can be performed in the dispersive way using a spectrometer consisting of a diffraction grating and a photo-detector array.[6

6. J. Schwider and L. Zhou, “Dispersive interferometric profiler,” Opt. Lett. 19, 995–997 (1994). [CrossRef] [PubMed]

,7

7. U. Schnell, E. Zimmermann, and R. Dändliker, “Absolute distance measurement with synchronously sampled white-light channeled spectrum interferometry,” Pure Appl. Opt. 4, 643–651 (1995). [CrossRef]

] This dispersive k- scanning permits utilizing the wide spectral range of white light, being considered a useful means of implementing white-light interferometry especially for vibration-desensitized surface profile measurements in harsh environment.

Recently, beyond the well-established capacity of 3-D surface profile metrology, whitelight interferometry began to find new applications in the realm of thickness profile measurement of thin-film layers. Multi-reflection occurring within a thin-film layer causes the resultant phase of white-light interferogram to yield a nonlinear variation with wavelength. Thus, least squares fitting of the measured phase into an appropriate analytical phase model of multi-reflection permits identifying the thickness profile of film layer. Feasibility of this new application was successfully demonstrated by way of z-scanning, [8

8. S.-W. Kim and G.-H. Kim, “Thickness-profile measurement of transparent thin-film layers by white-light scanning interferometry,” Appl. Opt. 38, 5968–5973 (1999). [CrossRef]

] k-scanning, [9

9. D. Kim, S. Kim, H. J. Kong, and Y. Lee, “Measurement of the thickness profile of a transparent thin-film deposited upon a pattern structure with an acousto-optic tunable filter,” Opt. Lett. 27, 1893–1895 (2002). [CrossRef]

] and dispersive k-scanning. [10

10. U. Schnell, R. Dändliker, and S. Gray, “Dispersive white-light interferometry for absolute distance measurement with dielectric multilayer systems on the target,” Opt. Lett , 21, 528–530 (1996). [CrossRef] [PubMed]

] Now, in this paper an improved version of dispersive k-scanning is proposed with the intention of replacing the time-consuming, iterative least squares fitting by a fast, deterministic method of Fourier transform analysis. Consequently a simple signal processing procedure of spectrally-resolved interference data allows not only the top surface height profile but also the thickness profile to be determined simultaneously, leading to the complete reconstruction of tomographical thickness profile of a thin-film layer.

2. Principles

Fig. 1 Optical configuration of dispersive white-light interferometry; LP: linear polarizer, BS: beam splitter, PBS: polarizing beam splitter, ES: entrance slit, DG: dispersive grating, CCD: charge coupled device.

Figure 1 shows the dispersive white-light interferometer configured in this investigation. A collimated beam of white light is linearly polarized and divided by a polarizing beam splitter so that the thin-film layer on the specimen is illuminated exclusively by p-polarization light, while the reference mirror only by s-polarization light. Two separate spectrometers, respectively designated S and T, are employed in parallel, each comprising an entrance slit, a diffractive grating, and a 2-D photodetector array of charge coupled devices. Spectrometer S is dedicated to only the self-interference occurring among the multi-reflected beams from the specimen, which can be done simply by blocking the reference beam of s-polarization using a linear polarizer. On the other hand, Spectrometer T receives the multi-reflected specimen beams as well as the reference beam by recombining all the beams through a 45°-rotated linear polarizer, which allows us to collect not only the self-interference of the specimen beams but also their individual cross-interferences with the reference beam. The source of white light in use is a tungsten halogen lamp emitting a Gaussian-shaped spectrum of 420 to 780 nm in wavelength, and Spectrometer S and T provide an identical wavelength resolution of 3 nm.

Fig. 2 Unfolded diagram depicting four major groups of spectrally-resolved interference signals between the reference and specimen. The reference beam is shown in blue and the multireflected beams from the specimen are in red. The parameter h denotes the distance between the reference mirror and the top surface, and d is the thickness of the thin-film layer.

The spectrally-resolved interference of white light is described using the spectral density G(ν) that represents the intensity output from a spectrometer as a function of the frequency ν. The interference observed by Spectrometer T encompasses all the contributions that are conveniently grouped into four separate terms as

G(v)=Grr(v)+n=0Gnn(v)
+n=0Gnr(v)cos[2π(τh+nτd)v]+n=0mnGnm(v)cos[2π(nm)τdv]
(1)

Fig. 2 depicts how the above four terms are generated individually. The first term Grr(ν) is the spectral intensity of the beam directly reflected from the reference mirror, while Gnn(ν) in the second term represents the spectral intensity of the n-th reflected beam from the specimen. The third term concerns the cross-interference of the reference beam with the n-th multireflected specimen beams. Lastly, the fourth term relates to the self-interference among the specimen beams, in which the subscripts n and m correspond to the n-th and m-th reflected beams, respectively.

The third and fourth terms, Gnr(ν) and Gnm(ν), involve two time delays, τh and τd; the first τh is associated with the top surface height h of the film layer that is measured with respect to the reference mirror, i.e., τh=2h/c, c being the speed of light in vacuum. The refractive index of air is assumed unity. The second time delay τd relates to the thickness d of the film layer, which is given as τd=2Nd/c with N being the group refractive index of the film. It is obvious that identifying τh and τd from the sampled G(ν) leads to measurement of the three important characterizing parameters of a thin film; h, d, and N. To that end, Eq. (1) is Fouriertransformed into the form of

FG(v)=Γrr(τ)+n=0Γnn(τ)
+n=0Γnr[τ+(τh+nτd)]+n=0Γnr[τ(τh+nτd)]
+n=0mnΓnm[τ+(nm)τd)]+n=0mnΓnm[τ(nm)τd)]
(2)

The overall result of FG(ν) is symmetrical about τ=0, since the measured signal of G(ν) is real, and appears as a series of peaks of varying amplitudes. Each peak in the positive τ domain is described as Γ[τ-τ*] with τ* being the peak center location. The peak width is affected by the spectral bandwidth of the source, which turns out to be 3.95 fs (FWHM) in our experiment. Each peak can be isolated by use of an appropriate filter such as the Heaviside function and inverse-Fourier-transformed to recover the phase ϕ(ν), following the double Fourier-transform theorem of F-1FG(ν)=|G(ν)| exp[iϕ(ν)]. Then, using the relation of ϕ(ν)=2πτ*ν, the delay is readily calculated in the deterministic way of τ*=(1/2π)(dϕ/dν). In doing that, overlap between neighboring peaks causes failure in obtaining the true value of τ*, so the minimum measurable limit of τ* is limited by the peak width (FWHM). Note that the maximum extent of τ* is also restricted; in this case by the Nyquist sampling limit that is described as τ* ≤1/(2p) in which p is the spectral resolution of the spectrometer in use.[11

11. K.-N. Joo and S.-W. Kim, “Absolute distance measurement by dispersive interferometry using a femtosecond pulse laser,” Opt. Express 14, 5954–5960 (2006). [CrossRef] [PubMed]

]

Fig. 3 Interference signals G(ν) vs. Fourier-transforms Γ(τ): (a) interference signal from Spectrometer T, (b) Fourier-Transform of (a), (c) interference signal from Spectrometer S, (d) Fourier-Transform of (c), (e) subtracted interference signal, and (f) Fourier-Transform of(e).

3. Experimental results

Figure 4 depicts how the group refractive index N of the thin film can be decided using a specimen particularly prepared with a stepped layer of thin film. Two sample points, S1 and S2 are selected; one located on the thick side and the other on the thin side. As the relative location of the reference mirror maintains a constant distance with regards to the bottom surface of the film layer deposited right on the flat substrate, the following condition holds; (h+d)1=(h+d)2 where subscripts 1 and 2 indicate the sampling points S1 and S2, respectively. This condition is rewritten in terms of the two time delays of τd and τh as (τhd/N)1=(τhd/N)2.

Fig. 4 Group refractive index measurement using a stepped film layer: (a) top view of a stepped SiO2 thin-film layer and (b) its cross sectional view of line A-A’.

This relation permits N to be decided as N=-(τd1d2)/(τh1h2), which is worked out to be 1.459 for the SiO2 layer used in this experiment. Dispersion occurring in the film layer of the specimen may cause variation of N with dependence on the film thickness, but its effect is found not significant when the thickness is less than a few micrometers.

Finally, two representative measurement results are shown in Fig. 5, which were taken from SiO2 thin-film layers deposited on silicon substrate with thickness ranging from 0.5 to 4.0 µm. One of the specimens shown in Fig. 5(a) has a ‘0’-patterned groove etched on the top surface of the SiO2 film of which bottom surface is flat. The other specimen shown in Fig. 5(c) has a flat top surface profile of a SiO2 layer that was polished by CMP(Chemical-Mechanical Polishing) Process after being deposited on a check-patterned silicon substrate. These examples demonstrate that the proposed dispersive method is capable of measuring the top surface profile and the film thickness at the same time with resolutions in the nanometer range. The minimum film thickness measurable is found ~0.5 µm, being limited by peak overlap in Γ(τ). The use of 2-D spectrometers enables us to measure one line at a time, so a lateral scanning stage was used for volumetric measurements. The measurement time for a single point is worked out to be ~3 ms when a standard PC equipped with an Intel Pentium 4 CPU run at 2.93 GHz is used.

Fig. 5 Exemplary measurement results: (a) 3-D thickness profile of ‘0” patterned SiO2 film layer on flat Si substrate, (b) cross sectional profile of (a), (c) 3-D thickness profile on patterned Si substrate, and (d) cross sectional profile of (c).

4. Conclusion

To conclude, the dual-branch detection scheme of dispersive white-light interferometry proposed in this investigation allows reconstructing the tomographical view of film layers with depth resolutions in the nanometer range. The refractive index of a film layer can also be determined to an accuracy of 10-3 without prior knowledge of geometrical thickness. The Fourier-transform signal processing procedure devised along with the proposed hardware scheme provides advantages of fast measurement speed, no need of mechanical depth scanning, and high immunity to external vibration. This method is currently restricted to single layer measurements, but extension to multiple layers is being under investigation. Finally, it is anticipated that the proposed method of dispersive white-light interferometry will be a powerful metrological tool for thin-film measurements with improved capabilities in terms of the measuring range, speed and accuracy for practical use especially for the semiconductor and flat panel display industry.

Acknowledgments

This work was supported by the Creative Research Initiatives Program of the Ministry of Science and Technology in the Republic of Korea.

References and links

1.

Y.-S. Ghim and S.-W. Kim, “Dispersive white-light interferometry for thin-film thickness profile measurement,” in Optical Measurement Systems for Industrial Inspection IV, W. Osten, C. Gorecki, and E. L. Novak, eds., in Proc. SPIE5856, 419–426 (2005). [CrossRef]

2.

P. De Groot and L. Deck, “Three-dimensional imaging by sub-Nyquist sampling of white-light interferograms,” Opt. Lett. 18, 1462–1464 (1993). [CrossRef] [PubMed]

3.

S. Kuwamura and I. Yamaguchi, “Wavelength scanning profilometry for real-time surface shape measurement,” Appl. Opt. 36, 4473–4482 (1997). [CrossRef] [PubMed]

4.

D. S. Mehta, S. Saito, H. Hinosugi, M. Takeda, and T. Kurosawa, “Spectral interference mirau microscope with an acousto-optic tunable filter for three-dimensional surface profilometry,” Appl. Opt. 42, 1296–1305 (2003). [CrossRef] [PubMed]

5.

M. Kinoshita, M. Takeda, H. Yago, Y. Watanabe, and T. Kurokawa, “Optical frequency-domain imaging microprofilometry with a frequency-tunable liquid-crystal Fabry-Perot etalon device,” Appl. Opt. 38, 7063–7068 (1999). [CrossRef]

6.

J. Schwider and L. Zhou, “Dispersive interferometric profiler,” Opt. Lett. 19, 995–997 (1994). [CrossRef] [PubMed]

7.

U. Schnell, E. Zimmermann, and R. Dändliker, “Absolute distance measurement with synchronously sampled white-light channeled spectrum interferometry,” Pure Appl. Opt. 4, 643–651 (1995). [CrossRef]

8.

S.-W. Kim and G.-H. Kim, “Thickness-profile measurement of transparent thin-film layers by white-light scanning interferometry,” Appl. Opt. 38, 5968–5973 (1999). [CrossRef]

9.

D. Kim, S. Kim, H. J. Kong, and Y. Lee, “Measurement of the thickness profile of a transparent thin-film deposited upon a pattern structure with an acousto-optic tunable filter,” Opt. Lett. 27, 1893–1895 (2002). [CrossRef]

10.

U. Schnell, R. Dändliker, and S. Gray, “Dispersive white-light interferometry for absolute distance measurement with dielectric multilayer systems on the target,” Opt. Lett , 21, 528–530 (1996). [CrossRef] [PubMed]

11.

K.-N. Joo and S.-W. Kim, “Absolute distance measurement by dispersive interferometry using a femtosecond pulse laser,” Opt. Express 14, 5954–5960 (2006). [CrossRef] [PubMed]

OCIS Codes
(070.4790) Fourier optics and signal processing : Spectrum analysis
(120.3180) Instrumentation, measurement, and metrology : Interferometry
(120.3940) Instrumentation, measurement, and metrology : Metrology
(120.5050) Instrumentation, measurement, and metrology : Phase measurement
(120.6200) Instrumentation, measurement, and metrology : Spectrometers and spectroscopic instrumentation
(310.6860) Thin films : Thin films, optical properties

ToC Category:
Thin Films

History
Original Manuscript: September 27, 2006
Revised Manuscript: November 9, 2006
Manuscript Accepted: November 13, 2006
Published: November 27, 2006

Citation
Young-Sik Ghim and Seung-Woo Kim, "Thin-film thickness profile and its refractive index measurements by dispersive white-light interferometry," Opt. Express 14, 11885-11891 (2006)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-24-11885


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. Y.-S. Ghim and S.-W. Kim, "Dispersive white-light interferometry for thin-film thickness profile measurement," in Optical Measurement Systems for Industrial Inspection IV, W. Osten, C. Gorecki, and E. L. Novak, eds., in Proc. SPIE 5856, 419-426 (2005). [CrossRef]
  2. P. De Groot and L. Deck, "Three-dimensional imaging by sub-Nyquist sampling of white-light interferograms," Opt. Lett. 18, 1462-1464 (1993). [CrossRef] [PubMed]
  3. S. Kuwamura and I. Yamaguchi, "Wavelength scanning profilometry for real-time surface shape measurement," Appl. Opt. 36, 4473-4482 (1997). [CrossRef] [PubMed]
  4. D. S. Mehta, S. Saito, H. Hinosugi, M. Takeda, and T. Kurosawa, "Spectral interference mirau microscope with an acousto-optic tunable filter for three-dimensional surface profilometry," Appl. Opt. 42, 1296-1305 (2003). [CrossRef] [PubMed]
  5. M. Kinoshita, M. Takeda, H. Yago, Y. Watanabe, and T. Kurokawa, "Optical frequency-domain imaging microprofilometry with a frequency-tunable liquid-crystal Fabry-Perot etalon device," Appl. Opt. 38, 7063-7068 (1999). [CrossRef]
  6. J. Schwider and L. Zhou, "Dispersive interferometric profiler," Opt. Lett. 19, 995-997 (1994). [CrossRef] [PubMed]
  7. U. Schnell, E. Zimmermann, and R. Dändliker, "Absolute distance measurement with synchronously sampled white-light channeled spectrum interferometry," Pure Appl. Opt. 4, 643-651(1995).Q1 [CrossRef]
  8. S.-W. Kim and G.-H. Kim, "Thickness-profile measurement of transparent thin-film layers by white-light scanning interferometry," Appl. Opt. 38, 5968-5973(1999). [CrossRef]
  9. D. Kim, S. Kim, H. J. Kong and Y. Lee, "Measurement of the thickness profile of a transparent thin-film deposited upon a pattern structure with an acousto-optic tunable filter," Opt. Lett. 27, 1893-1895 (2002). [CrossRef]
  10. U. Schnell, R. Dändliker and S. Gray, "Dispersive white-light interferometry for absolute distance measurement with dielectric multilayer systems on the target," Opt. Lett,  21, 528-530 (1996). [CrossRef] [PubMed]
  11. K.-N. Joo and S.-W. Kim, "Absolute distance measurement by dispersive interferometry using a femtosecond pulse laser," Opt. Express 14, 5954-5960 (2006). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4 Fig. 5
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited