OSA's Digital Library

Optics Express

Optics Express

  • Editor: Martijn de Sterke
  • Vol. 16, Iss. 20 — Sep. 29, 2008
  • pp: 16189–16194
« Show journal navigation

Entangled-photon coincidence fluorescence imaging

Giuliano Scarcelli and Seok H. Yun  »View Author Affiliations


Optics Express, Vol. 16, Issue 20, pp. 16189-16194 (2008)
http://dx.doi.org/10.1364/OE.16.016189


View Full Text Article

Acrobat PDF (395 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We describe fluorescence imaging using the second-order correlation of entangled photon pairs. The proposed method is based on the principle that one photon of the pair carries information on where the other photon has been absorbed and has produced fluorescence in a sample. Because fluorescent molecules serve as “detectors” breaking the entanglement, multiply-scattered fluorescence photons within the sample do not cause image blur. We discuss experimental implementations.

© 2008 Optical Society of America

1. Introduction

Entangled photons have recently attracted considerable interest in the optics community for potential applications in precision metrology, information processing, and imaging [1

1. J. P. Dowling and G. J. Milburn, “Quantum technology: the second quantum revolution,” Phil. Trans. R. Soc. London A 361, 1655–1674 (2003); [CrossRef]

,2

2. N. Gisin and R. Thew, “Quantum communication,” Nat. Photonics 1, 165–171 (2007). [CrossRef]

]. Coincidence imaging, or ghost imaging, was pioneered ten years ago, using entangled photon pairs that are typically generated via spontaneous parametric down conversion (SPDC) [3

3. T. B. Pittman, Y. H. Shih, D. V. Strekalov, and A. V. Sergienko, “Optical imaging by means of two-photon quantum entanglement,” Phys. Rev. A 52, R3429–R3432 (1995). [CrossRef] [PubMed]

,4

4. A. V. Belinskii and D. N. Klyshko, “Two-Photon Optics - Diffraction, Holography and Transformation of 2-Dimensional Signals,” JETP 105, 487–493 (1994).

]. In this technique, one photon of the pair probes a distant object, while the other serves as a reference. The correlation in position and momentum of the entangled photons allows the object to be imaged remotely by measuring the position of the reference photon coincident with the probe photon. Classical light sources also can be used for coincidence imaging even though they cannot replicate all the features the entangled source can produce [5

5. R. S. Bennink, S. J. Bentley, and R. W. Boyd, ““Two-photon” coincidence imaging with a classical source,” Phys. Rev. Lett. 89, 113601 (2002). [CrossRef] [PubMed]

7

7. A. Valencia, G. Scarcelli, M. D’Angelo, and Y. Shih, “Two-photon imaging with thermal light,” Phys. Rev. Lett. 94, 063601 (2005). [CrossRef] [PubMed]

]. To date, coincidence imaging has been studied with simple intensity masks or phase objects [8

8. A. F. Abouraddy, P. R. Stone, A. V. Sergienko, B. E. A. Saleh, and M. C. Teich, “Entangled-photon imaging of a pure phase object,” Phys. Rev. Lett. 93, 213903 (2004). [CrossRef] [PubMed]

].

In this paper, we propose a new method to extend the entangled coincidence imaging to fluorescent samples. We describe the principle and implementations of the method and compare it with classical imaging techniques widely used in biological applications.

2. Working principle

Consider the imaging setup shown in Fig. 1(a). A pair of entangled photons is generated by SPDC. The probe photon is directed to a sample containing fluorescence molecules. One of the molecules may absorb the probe photon, be excited, and generate a new photon with the Stokes frequency (wavelength) shift. This fluorescence photon is then detected by a “bucket” photon-counting detector (D1). A dichroic filter allows only fluorescence photons to be registered, rejecting any probe photons that have passed through or scattered off the sample without being absorbed. On the other hand, the reference photon is detected by an array of photon-counting detectors, and the position and time of arrival are registered. Because the entangled photons are simultaneously generated in the SPDC crystal, an ideal lossless system ensures that whenever D1 detects a fluorescence photon, one of the detector elements in D2 will capture the reference photon (the reverse would not be true if the probe-to-fluorescence conversion did not occur). The position and momentum of the reference and probe photons are correlated to each other. Therefore, from the measured location of the coincident reference photon, one can obtain information on where the probe photon was absorbed, i.e. the location of the fluorophore. By repeating such a measurement for many entangled photon pairs generated sequentially, one can produce a fluorescence image of the sample.

Fig. 1. Principle of entangled-photon fluorescence imaging. (a) Imaging system schematic. (b) The intrinsic correlation function of entangled photon pair measured with ideal fast detectors. (c) The correlation function broadened by fluorescence molecules and detectors. τ F and τ d are time delays due to the fluorescence lifetime and the photon propagation from the molecule to the detector. The integration time T is chosen to be longer than these time constants.

The exact time difference between detecting the reference and fluorescence photons, τ 1-τ 2, is somewhat uncertain because of random optical and electrical time delays in the system. For example, fluorescence emission is a stochastic process with a lifetime, and the photon-counting module has a finite electronic timing jitter. These timing uncertainties, however, can be accommodated by having a correlation time window, T, longer than these time delays [Fig. 1(b) and (c)]. In each correlation window, no more than one entangled photon pair should be dealt with, ideally, in order to avoid any erroneous correlation count.

3. Theory

Applying Glauber’s quantum theory of photodetection [9

9. R. J. Glauber, “Quantum theory of optical coherence,” Phys. Rev. 130, 2529 (1963). [CrossRef]

], we point out that the photo-absorption by fluorescence molecules must be regarded as the “detection” event upon which the probe photon is annihilated, the quantum state of the entangled photon pair is determined, and any correlation or coherence between the probe and reference photons is terminated. Any processes after the absorption, including fluorescence emission, the propagation of fluorescence photon, and photoelectric conversion at D1, merely serve as couriers delivering the detected signal with time delay.

Using Glauber’s mathematical formalism of the second-order correlation, we express the coincidence rate function as:

I(2)(r1;r2)=Tdτ1dτ2GF(2)(r1,τ1;r2,τ2)T,
(1)

where

GF(2)=dt1dt2dtFG(2)(r1,t1;r2,t2)F(r1,tFt1)γ1(τ1tF)γ2(τ2t2).
(2)

Here G (2) is the intrinsic second-order correlation function computed in the case of ideal detectors, whereas G (2) F is the correlation function taking into account the temporal convolution imposed by the finite response time of fluorescence generation and photoelectric conversion; F(r1, t) denotes the probability function of fluorescence generation, F(r1, t)=f(r1)exp(-t/τ F)H(t)/τ F where F(r1) describes the spatial distribution and concentration of fluorescence molecules, τ F is the fluorescence lifetime, typically 0.2–5 ns, and H(t) is the Heaviside step function. γ 1,2(t) denotes the response function of the photo-electric detectors, that can be approximated to a Gaussian function with a width of 0.2–1 ns. D1 integrates all the fluorescence photons emitted in a sample volume V. Therefore, the final measured quantity is the marginal coincidence counting rate R C:

Rc(r2)=Vdr1I(2)(r1;r2)
(3)

The purpose of the setup is to retrieve f(r1) from the measurement of R c(r2).

Figure 2 shows the equivalent ray-optic diagram [4

4. A. V. Belinskii and D. N. Klyshko, “Two-Photon Optics - Diffraction, Holography and Transformation of 2-Dimensional Signals,” JETP 105, 487–493 (1994).

] of an imaging setup similar to Fig. 1(a), in which an objective lens is inserted in the probe arm. In a simplified picture, the probe and reference photons are generated at the same time and at the same location rc in the SPDC crystal and have perfectly phase-matched wave vectors, k1 and k2, i.e. k1+k2=kp where kp is the wave vector of the pump photon. From these properties, the beam propagation paths linking two points r1 and r2 can be identified, as represented by a red shaded region in Fig. 2. From the quantum optical viewpoint, the second-order correlation is established as coherent linear superposition of all of the correlation beam paths. Nevertheless, the classical ray picture is adequate to understand the imaging relationship as follows. The phase matching condition leads to a Snell’s-law-like relation at the crystal interface: λ2 sinθ1=λ1sinθ2 where λ1 and λ2 denote the wavelengths of probe and reference photons, respectively. Simple ray tracing leads to an imaging equation [10

10. A. F. Abouraddy, B. E. A. Saleh, A. V. Sergienko, and M. C. Teich, “Entangled-photon Fourier optics,” J. Opt. Soc. Am. B 19, 1174–1184 (2002). [CrossRef]

]:

1s1+1a+(λ2λ1)b=1fobj,
(4)

where f obj denotes the focal length of the objective lens. This relation asserts that the imaging

plane distance, s 1, can be varied in the sample remotely by changing the distance, b, of the

reference detector. The wavelength dependence in Eq. (4) plays a similar role as chromatic

aberration and may cause image blur if broadband spectra are used. This problem, however,

can be avoided by spectral selection of correlated pairs or with an infinite conjugate imaging

setup that employs an imaging lens in front of D2. On the other hand, the wavelength

dependence may be used advantageously in conjunction with wavelength tuning to allow the

imaging focal plane to be adjusted, even without moving the reference detector.

Fig. 2. Unfolded geometrical beam paths. The brown and green shaded regions depict all the possible optical paths of the probe and reference photons. Solid line traces (black) represent correlation beam paths between r 1 and r 2.

Any fluorescence molecules within the beam correlation region (red shade) can be excited by the probe photon with probability proportional to the local optical intensity, but any fluorescence photon emitted from this region, regardless of its true origin, will be assigned to r1, the conjugate location to r2. In this sense, the imaging system considered here is similar to classical wide-field fluorescence imaging.

Using Fourier optics formalism [10

10. A. F. Abouraddy, B. E. A. Saleh, A. V. Sergienko, and M. C. Teich, “Entangled-photon Fourier optics,” J. Opt. Soc. Am. B 19, 1174–1184 (2002). [CrossRef]

], the coincidence rate function can be expressed as

I(2)(r1;r2)f(r1)drch1(r1;rc)h2(r2;rc)2,
(5)

where h 1,2 are the 3D classical impulse response function of the probe and reference arms, respectively. When the imaging relationship given by Eq. (4) is established with 1:1 magnification, we get I (2)(r1;r2)≈f(r1)δ(r1-r2) and R C(r2)∝f(r2) from Eq. (3). Imaging resolution can be analyzed by considering a point object f(r1)=δ(r1). From standard diffraction calculation, it can be shown that the system’s resolution is identical to that of a classical standard microscope using the wavelength of λ 1.

4. Practical considerations

Considering fluorescence dye solution as a sample, we estimate the maximum achievable coincidence counting rate to be R CN 0(1-e-mεL)η F η c η 1 η 2, where N 0 is the number of entangled photon pairs generated per second, m the molar concentration, ε the extinction coefficient, L the sample thickness, η F the quantum efficiency of the fluorophore, η c the geometrical collection efficiency of the bucket detector D1, and η 1,2 are the quantum efficiency of the detectors. As an example, we consider a near-infrared fluorescence dye, Alexa-Fluor 700 (Invitrogen), which is widely used in biological imaging. Its peak absorption wavelength 700 nm is suited for a SPDC source pumped by an Argon laser at 351 nm [3

3. T. B. Pittman, Y. H. Shih, D. V. Strekalov, and A. V. Sergienko, “Optical imaging by means of two-photon quantum entanglement,” Phys. Rev. A 52, R3429–R3432 (1995). [CrossRef] [PubMed]

]. The dye has ε=~20 M-1µm-1, η F=0.25, and τ F=1 ns. Let us consider an experiment where D2 is a large scale array [10

10. A. F. Abouraddy, B. E. A. Saleh, A. V. Sergienko, and M. C. Teich, “Entangled-photon Fourier optics,” J. Opt. Soc. Am. B 19, 1174–1184 (2002). [CrossRef]

]. In practice, we can have N 0=4×106 pairs per second, T=10 ns, and a pixel dead-time of 50 ns. Based on the Poisson distribution, the error probability of having more than one photon pair in 10 ns is only 0.08 %. For a sample with m=100 µM and L=20 µm, we estimate that about 4% of probe photons are absorbed in the sample. Using η c=0.5, and η 1,2=0.7, we get R C=10,000 counts per second. At this rate, the pixel acquisition time for collecting average 100 counts per pixel would be ~10 ms. Therefore, it will take about 100 sec to acquire an 8-bit 100×100 image. Alternatively, a single- or few-element detector can be scanned in 2D at the expense of acquisition time.

5. Spectrally-encoded entangled fluorescence spectroscopy and imaging

As a variant of the principle, here we briefly describe how to use entanglement in frequency rather than the entanglement in position and momentum for fluorescence measurement. Phase matching in SPDC leads to ω 1+ω 2=ω P where ω 1,2,P are the frequencies of probe, reference, and pump photons, respectively. This indicates that one can determine ω 1, without directly analyzing the spectrum of the probe photon, by measuring ω 2 of the reference photon [12

12. G. Scarcelli, A. Valencia, S. Gompers, and Y. Shih, “Remote spectral measurement using entangled photons,” Appl. Phys. Lett. 83, 5560–5562 (2003). [CrossRef]

]. Combined with the coincidence counting measurement, this principle can be used for fluorescence absorption spectroscopy and imaging [Fig. 3] based on spectral encoding [13

13. J. T. Motz, D. Yelin, B. J. Vakoc, B. E. Bouma, and G. J. Tearney, “Spectral- and frequency-encoded fluorescence imaging,” Opt. Lett. 30, 2760–2762 (2005). [CrossRef] [PubMed]

]. Since this method does not use the entanglement in position and momentum, it can be easily implemented in practice with optical fibers.

Fig. 3. Spectrally-encoded coincidence imaging. Orthogonally polarized entangled photons are separated into a fiber-optic probe and reference arms. The probe photon is spectrally dispersed and focused to a sample. Fluorescence photon (red) is collected by a large-area bucket detector, D1, and the position of the excited fluorescence molecule is determined by measuring the frequency (wavelength) of reference photon.

6. Discussion and conclusion

Coincidence imaging offers a number of interesting features. First, our method is based on the second-order correlation measurement. To date, only direct detection (wide-field, confocal, or two-photon microscopy) and the first-order correlation (4π microscopy) have been used for fluorescence imaging. Second, multiple scattering of fluorescence photons in a sample does not blur images. Figure 4(a) illustrates a situation in which a fluorescence photon undergoes elastic scattering before reaching the detector D1. Scattering of the fluorescence photon may affect the detection time τ 1, but does not perturb the image retrieval because fluorescence is an incoherent process so that no position correlation exists between the fluorescence and reference photons. On the other hand, any elastic scattering events of the probe photon before it reaches the fluorophore [Fig. 4(b)] does affect the correlation property between the probe and reference photons, resulting in speckle-type image degradation. Third, only a single-element detector is required in the probe arm, which may collect all the fluorescence photons. This may be advantageous where a 2D detector array is not readily available at the fluorescence wavelength or when it is difficult to place it near the sample; for instance, in endoscopy. Two-photon microscopy also uses a bucket detector to collect fluorescence photons generated by nonlinear absorption, but it requires a high numerical aperture (NA) objective lens, mode-locked femtosecond laser, and beam scanning device [14

14. W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science 248, 73–76 (1990). [CrossRef] [PubMed]

].

Fig. 4. The effect of multiple scattering in a sample.

Classical light sources, such as thermal chaotic light [6

6. A. Gatti, E. Brambilla, M. Bache, and L. A. Lugiato, “Correlated imaging, quantum and classical,” Phys. Rev. A 70, 013802 (2004). [CrossRef]

] and synchronized momentum-correlated sources [5

5. R. S. Bennink, S. J. Bentley, and R. W. Boyd, ““Two-photon” coincidence imaging with a classical source,” Phys. Rev. Lett. 89, 113601 (2002). [CrossRef] [PubMed]

], could be used for coincidence fluorescence imaging. However, only quantum correlations ensure both background-free coincidence and remote tunability of the imaging plane distance, s 1 [7

7. A. Valencia, G. Scarcelli, M. D’Angelo, and Y. Shih, “Two-photon imaging with thermal light,” Phys. Rev. Lett. 94, 063601 (2005). [CrossRef] [PubMed]

]. While our discussion here focuses on fluorescence, the same principle of operation applies to detecting other inelastic processes, such as Raman scattering. However, the small cross section of spontaneous Raman scattering may lead to impractically low signal count.

In conclusion, we have presented a novel method for fluorescence imaging and spectroscopy based on coincidence measurement of entangled photons.

References and links

1.

J. P. Dowling and G. J. Milburn, “Quantum technology: the second quantum revolution,” Phil. Trans. R. Soc. London A 361, 1655–1674 (2003); [CrossRef]

2.

N. Gisin and R. Thew, “Quantum communication,” Nat. Photonics 1, 165–171 (2007). [CrossRef]

3.

T. B. Pittman, Y. H. Shih, D. V. Strekalov, and A. V. Sergienko, “Optical imaging by means of two-photon quantum entanglement,” Phys. Rev. A 52, R3429–R3432 (1995). [CrossRef] [PubMed]

4.

A. V. Belinskii and D. N. Klyshko, “Two-Photon Optics - Diffraction, Holography and Transformation of 2-Dimensional Signals,” JETP 105, 487–493 (1994).

5.

R. S. Bennink, S. J. Bentley, and R. W. Boyd, ““Two-photon” coincidence imaging with a classical source,” Phys. Rev. Lett. 89, 113601 (2002). [CrossRef] [PubMed]

6.

A. Gatti, E. Brambilla, M. Bache, and L. A. Lugiato, “Correlated imaging, quantum and classical,” Phys. Rev. A 70, 013802 (2004). [CrossRef]

7.

A. Valencia, G. Scarcelli, M. D’Angelo, and Y. Shih, “Two-photon imaging with thermal light,” Phys. Rev. Lett. 94, 063601 (2005). [CrossRef] [PubMed]

8.

A. F. Abouraddy, P. R. Stone, A. V. Sergienko, B. E. A. Saleh, and M. C. Teich, “Entangled-photon imaging of a pure phase object,” Phys. Rev. Lett. 93, 213903 (2004). [CrossRef] [PubMed]

9.

R. J. Glauber, “Quantum theory of optical coherence,” Phys. Rev. 130, 2529 (1963). [CrossRef]

10.

A. F. Abouraddy, B. E. A. Saleh, A. V. Sergienko, and M. C. Teich, “Entangled-photon Fourier optics,” J. Opt. Soc. Am. B 19, 1174–1184 (2002). [CrossRef]

11.

S. Bellis, R. Wilcock, and C. Jackson, “Photon counting imaging: the digital APD,” Proc. SPIE 6068, 6068D (2006).

12.

G. Scarcelli, A. Valencia, S. Gompers, and Y. Shih, “Remote spectral measurement using entangled photons,” Appl. Phys. Lett. 83, 5560–5562 (2003). [CrossRef]

13.

J. T. Motz, D. Yelin, B. J. Vakoc, B. E. Bouma, and G. J. Tearney, “Spectral- and frequency-encoded fluorescence imaging,” Opt. Lett. 30, 2760–2762 (2005). [CrossRef] [PubMed]

14.

W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science 248, 73–76 (1990). [CrossRef] [PubMed]

OCIS Codes
(170.2520) Medical optics and biotechnology : Fluorescence microscopy
(270.0270) Quantum optics : Quantum optics

ToC Category:
Quantum Optics

History
Original Manuscript: July 8, 2008
Revised Manuscript: August 22, 2008
Manuscript Accepted: August 29, 2008
Published: September 26, 2008

Virtual Issues
Vol. 3, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Giuliano Scarcelli and Seok H. Yun, "Entangled-photon coincidence fluorescence imaging," Opt. Express 16, 16189-16194 (2008)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-20-16189


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. P. Dowling and G. J. Milburn, "Quantum technology: the second quantum revolution," Phil. Trans. R. Soc. London A 361, 1655-1674 (2003); [CrossRef]
  2. N. Gisin and R. Thew, "Quantum communication," Nat. Photonics 1, 165-171 (2007). [CrossRef]
  3. T. B. Pittman, Y. H. Shih, D. V. Strekalov, and A. V. Sergienko, "Optical imaging by means of two-photon quantum entanglement," Phys. Rev. A 52, R3429-R3432 (1995). [CrossRef] [PubMed]
  4. A. V. Belinskii and D. N. Klyshko, "Two-Photon Optics - Diffraction, Holography and Transformation of 2-Dimensional Signals," JETP 105, 487-493 (1994).
  5. R. S. Bennink, S. J. Bentley, and R. W. Boyd, ""Two-photon" coincidence imaging with a classical source," Phys. Rev. Lett. 89, 113601 (2002). [CrossRef] [PubMed]
  6. A. Gatti, E. Brambilla, M. Bache, and L. A. Lugiato, "Correlated imaging, quantum and classical," Phys. Rev. A 70, 013802 (2004).Q4 [CrossRef]
  7. A. Valencia, G. Scarcelli, M. D'Angelo, and Y. Shih, "Two-photon imaging with thermal light," Phys. Rev. Lett. 94, 063601 (2005). [CrossRef] [PubMed]
  8. A. F. Abouraddy, P. R. Stone, A. V. Sergienko, B. E. A. Saleh, and M. C. Teich, "Entangled-photon imaging of a pure phase object," Phys. Rev. Lett. 93, 213903 (2004). [CrossRef] [PubMed]
  9. R. J. Glauber, "Quantum theory of optical coherence," Phys. Rev. 130, 2529 (1963). [CrossRef]
  10. A. F. Abouraddy, B. E. A. Saleh, A. V. Sergienko, and M. C. Teich, "Entangled-photon Fourier optics," J. Opt. Soc. Am. B 19, 1174-1184 (2002). [CrossRef]
  11. S. Bellis, R. Wilcock, and C. Jackson, "Photon counting imaging: the digital APD," Proc. SPIE 6068, 6068D (2006).
  12. G. Scarcelli, A. Valencia, S. Gompers, and Y. Shih, "Remote spectral measurement using entangled photons," Appl. Phys. Lett. 83, 5560-5562 (2003). [CrossRef]
  13. J. T. Motz, D. Yelin, B. J. Vakoc, B. E. Bouma, and G. J. Tearney, "Spectral- and frequency-encoded fluorescence imaging," Opt. Lett. 30, 2760-2762 (2005). [CrossRef] [PubMed]
  14. W. Denk, J. H. Strickler, and W. W. Webb, "Two-photon laser scanning fluorescence microscopy," Science 248, 73-76 (1990). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1. Fig. 2. Fig. 3.
 
Fig. 4.
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited