Abstract

The use of optical metrology techniques in process control for microelectronic manufacturing has become widespread. These techniques are fast and non-destructive, allowing a higher sampling rate than non-optical methods like scanning electron or atomic force microscopy. One drawback of most optical metrology tools is the requirement that special measurement structures be fabricated in the scribe line between chips. This poses significant limitations regarding the characterization of lithography processes that may be overcome via in-chip measurements. In this paper we present experimental results for an in-chip optical metrology technique that allows direct measurement of both critical dimensions and overlay displacement errors in the DRAM manufacturing process. This technique does not require special target structures and is performed on the actual semiconductor devices.

© 2009 OSA

1. Introduction

Scanning Electron Microscopy (SEM) has been traditionally used in the semiconductor manufacturing process for memory devices to monitor critical dimensions (CDs). However, with the rapid shrinking of devices at every new technology node and relentless demand for higher yield in recent years, the limitations of CD-SEM, such as the charging effect that compromises repeatability and accuracy, restrained sampling rate, and small aerial coverage, have been recognized as a bottleneck for further yield enhancement in advanced memory fabrication facilities. Standing out among the alternative approaches that have been developed is optical critical dimension (OCD) metrology [1

1. C. J. Raymond, “Scatterometry for Semiconductor Metrology,” Handbook of silicon semiconductor metrology, A.C. Diebold, ed., (Academic press 2001), Chap. 18, p.477–514.

] using optical scatterometry with rigorous coupled wave analysis (RCWA) modeling. CD-SEM measurements are typically limited to the top surface layer and must be applied at every process step. However, OCD can eliminate this redundancy and characterize the entire target structure down to the silicon substrate in a single measurement, provided photons are able to penetrate the target structure. In addition, CD-SEM may also damage the material via reaction to high-energy electrons, potentially creating fatal defects at the measurement site, whereas OCD has no such effect. With high throughput and larger sample coverage compared to CD-SEM, OCD also enables measurements at or near the wafer edge, which has been identified as the one of the key elements to yield enhancement. As a result, OCD has become an established metrology technology over the last few years, and is widely used in most memory fabrication facilities around the world.

In this paper, we show a novel OCD technology based on spectroscopic Mueller Matrix ellipsometry that can determine both CD and overlay registration error. This technique is applied to patterned structures in memory fabrication, where cross-sectional misalignment is observed between different layers. The existing method of image-based overlay (IBO) typically uses special targets located outside the chip which are typically two orders of magnitude larger in line and space dimensions than the actual cell devices. IBO is problematic in that it has shown deviations from the actual device overlay error within the die (chip) [2

2. N. P. Smith, “Overlay metrology at the crossroads,” Proc. SPIE 6922, 0277–0286 (2008).

]. The shrinking of devices in the current and future technology nodes makes the measurement of overlay errors in scribe line IBO targets insufficient to represent the true overlay error in the actual device area, especially due to process effects like micro-loading [3

3. C. Hedlund, H.-O. Blom, and S. Berg, “Microloading effect in reactive ion etching,” J. Vac. Sci. Technol. A 12(4), 1962–1965 ( 1994). [CrossRef]

]. This is becoming a pressing yield issue for memory manufacturers.

A direct overlay measurement in the device may result in substantial savings in real estate within the wafer since there is no longer a need for special targets on the scribe line. More sophisticated sampling schemes also become possible as much of the device areas in the chip are available for measurement, whereas metrology in the scribe lines is limited to a per die sampling rate. This technique is particularly useful when applied at the after-develop inspection (ADI) step, as it allows manufacturers to rework their process without scrapping wafers. It is also expected that OCD technology will become an indispensible metrology technique in advanced technology nodes below 40 nm, where double-patterning and/or immersion lithography are often required.

2. Methodology

2.1 Experimental Configuration

The apparatus used in this experiment, shown schematically in Fig. 1
Fig. 1 Broadband spectroscopic rotating compensator ellipsometer used in this paper.
, consists of a focused beam rotating compensator spectroscopic ellipsometer (SE) in the PCSA configuration, where P stands for the polarizer, C for the rotating compensator, S for the sample and A for the analyzer. With the light sources used in this SE (J. A. Woollam Co. Model M2000), the wavelengths available are in the 200-1000 nm range. Data collection is performed in the specular mode at 65° angle of incidence and the azimuth angle (between the plane of incidence and the grating axis) can be chosen for maximum sensitivity. The light intensity at the spectrometer is described by the first component of the Stokes vector S and follows the equation

Sout=[MAR(A)]MSample[R1(C)MCR(C)][R1(P)MP]Sin
(1)

In the above R(θ) and Mi are the corresponding rotation and Mueller matrices for each optical element [4

4. K. Rochford, “Polarization and polarimetry,” NIST publication, http://boulder.nist.gov/div815/81503_pubs/PPMDocs/Rochford-EPST-02.pdf

]. The angle θ describes the azimuths of P & A and also the fast axis angle of the compensator C. The compensator is rotating continuously and by the analysis of the signal from the spectrometer one can obtain the elements of the sample Mueller matrix. In this single rotating compensator configuration we get 12 (first 3 rows) out of the 16 Mueller elements, see Collins [5

5. R. W. Collins, Handbook of Ellipsometry, H. G. Tompkins and E. A. Irene, eds., (William Andrew Publishing & Springer-Verlag, 2005), Chap. 7.3.3, p 546–566.

] for details on data reduction.

In the absence of depolarization, as it is the case with our samples, the sample-light interaction is described by the Jones reflection matrix

J=(rssrsprpsrpp)
(2)

Msample=TJJ*T1
(3)

Where the matrix T is given by

T=(1001100101100ii0)
(4)

2.2 Misalignment or overlay error detection from the sample Mueller matrix

To perform an OCD measurement, we compare the experimental Mueller matrix elements to simulated data using the RCWA formulation for 3D objects (2D periodic array) [6

6. L. Li, “New formulation of the Fourier modal method for crossed surface relief gratings,” J. Opt. Soc. Am. A 14(10), 2758–2767 ( 1997). [CrossRef]

]. The model is adjusted by means of nonlinear regression until an acceptable match is found. The Mueller elements are sensitive to the profile details of the structures as well as any asymmetries present, e.g. any misalignment between objects at different levels in the structure. The Physics behind the use of Mueller SE for the detection of misalignment relies on the key fact that the Jones cross-polarization reflectance coefficients (rps and rsp) are anti-symmetric for symmetric structures and this condition is violated in the presence of structural asymmetry. For symmetric gratings the specular, or 0th order, cross reflection coefficients in the conical mount, are known to be anti-symmetric, i.e. rsp = −rps [7

7. L. Li, “Symmetries of cross-polarization diffraction coefficients of gratings,” J. Opt. Soc. Am. A 17(5), 881–887 ( 2000). [CrossRef]

]. When the grating symmetry is broken this relationship is violated and we have rsp ≠ −rps, which can be exploited for misalignment control, or overlay metrology. This property of the Jones matrix for symmetric structures translates for the Mueller elements available from our SE into:

M13+M31=0M23+M32=0
(5)

In the regime of small overlay errors there should be a linear relationship between the (anti-) symmetry breaking term and overlay displacement δx, i.e.
M13+M31=C1δxM23+M32=C2δx
(6)
where C1 and C2 are constants. To test this hypothesis, sample were prepared by intentionally programming a 0.3 ppm linear overlay displacement expansion to the DRAM production wafers. The intention was to collect Mueller Matrix SE (MM-SE) data on the device area as well as traditional IBO data from targets that surround each chip for correlation to a reference metrology. In the following we give a detailed description of the sample used in this experiment, as well as the experimental results.

3. Samples & Experimental Description

3.1 Recess Channel Array Transistor (RCAT) structure

3.2 Overlay response

We first study the spectral response of MM-SE measurement to overlay error. Because of the complex 3D lattice of this RCAT structure, it is possible to take MM-SE data along one of the several high symmetry azimuth angles. A sensitivity study of the SE plane of incidence azimuth angle reveals that the spectral response to overlay error depends strongly on the measurement azimuth and the best sensitivity is achieved at 26° azimuth angle with respect to the top grating lines and orthogonal to the long axis of the STI island (A detailed description of sensitivity studies for azimuth angle optimization can be found in [8

8. P. Vagos, J. Hu, Z. Liu, and S. Rabello, “Uncertainty and Sensitivity Analysis and its application in OCD measurements,” Proc. of SPIE 7272, 72721N–72721N–9 (2009)

]). The MM SE measurement, therefore, was carried out at 26° azimuth angle.

From Eq. (6), the amplitude of M13 + M31 directly corresponds to the asymmetry induced by the overlay error of RCAT ADI structure and the spectrum between 245 and 265 nm gives best sensitivity to overlay shift. Figure 5
Fig. 5 Average response (over wavelengths in the 245-265 nm range) of the sum M13 + M31 vs. overlay shift.
shows the average spectral response to overaly shift within this wavelength range. The mean response is nearly linear within ± 15 nm of overlay error.

4. OCD (RCWA) Modeling and Overlay Results

4.1 Modeling

An OCD model was built using NanoDiffractTM software to perform a non-linear regression of the model to best fit the MM SE spectra (Fig. 6
Fig. 6 RCWA fit to the experimental Mueller matrix data.
). Besides overlay shift, the model also provides the profile of the STI island (x & y CD, height, SWA), profile of the photo-resist line (CD, height, SWA), and the thickness of the films between the two gratings. It is necessary to float all these parameters to track process variation and achieve good fitting quality. Figure 6 shows a typical set of measured and best-fit spectra for 11 MM SE elements (M11≡1 in our configuration) from the RCAT ADI structure. Note that the M13 (M23) and M31 (M32) spectra are nearly the reverse of each other. The change induced by the overlay shift is relatively small compared to the amplitude of the spectrum.

The overlay error, as well as other profile information, was obtained by fitting the above OCD model to the measured spectra. Figure 7
Fig. 7 Correlation between MM SE in-chip overlay measurement and imaging overlay measurement on the scribe line. The insert shows the correlation of the OCD PR line width measurement to CDSEM.
shows a plot of the correlations between the overlay and CD of the photoresist line (Fig. 7 insert) from the in-chip Mueller-SE measurement against reference techniques. The CD reference was taken by CD-SEM in the device area and the overlay reference was taken by IBO on the targets in the scribe line surrounding the device area. The photoresist CD has a linear correlation to the CD-SEM results with an R2 of 0.986 and the overlay has a linear correlation to IBO with an R2 of 0.987. These excellent correlations demonstrate the superior capability of MM-SE technique combined with OCD modeling for measuring simultaneously CD and in-chip overlay on complex DRAM structures. This additional capability not only extends the application of OCD techniques to overlay metrology, but also greatly improves the turn-around time and cost of ownership (COO) by reducing the metrology steps and equipment required.

5. Concluding remarks

By utilizing a broadband spectroscopic rotating compensator ellipsometer with Mueller matrix capability we demonstrate a novel overlay and critical dimension metrology technique for advanced semiconductor manufacturing. Exploiting fundamental symmetries in the physics of periodic structures and polarized light we proved that it is possible to measure overlay registration error in the device area of actual memory chips. Contrary to traditional imaging overlay metrology this technique does not require special targets placed outside the device area therefore allowing a better understanding of the impact of in-chip overlay and CD errors on production yield. The results of this paper can be extended and applied to high-volume manufacturing, not only for other DRAM structures, but also to flash memory and logic structures.

References and Links

1.

C. J. Raymond, “Scatterometry for Semiconductor Metrology,” Handbook of silicon semiconductor metrology, A.C. Diebold, ed., (Academic press 2001), Chap. 18, p.477–514.

2.

N. P. Smith, “Overlay metrology at the crossroads,” Proc. SPIE 6922, 0277–0286 (2008).

3.

C. Hedlund, H.-O. Blom, and S. Berg, “Microloading effect in reactive ion etching,” J. Vac. Sci. Technol. A 12(4), 1962–1965 ( 1994). [CrossRef]

4.

K. Rochford, “Polarization and polarimetry,” NIST publication, http://boulder.nist.gov/div815/81503_pubs/PPMDocs/Rochford-EPST-02.pdf

5.

R. W. Collins, Handbook of Ellipsometry, H. G. Tompkins and E. A. Irene, eds., (William Andrew Publishing & Springer-Verlag, 2005), Chap. 7.3.3, p 546–566.

6.

L. Li, “New formulation of the Fourier modal method for crossed surface relief gratings,” J. Opt. Soc. Am. A 14(10), 2758–2767 ( 1997). [CrossRef]

7.

L. Li, “Symmetries of cross-polarization diffraction coefficients of gratings,” J. Opt. Soc. Am. A 17(5), 881–887 ( 2000). [CrossRef]

8.

P. Vagos, J. Hu, Z. Liu, and S. Rabello, “Uncertainty and Sensitivity Analysis and its application in OCD measurements,” Proc. of SPIE 7272, 72721N–72721N–9 (2009)

OCIS Codes
(050.1950) Diffraction and gratings : Diffraction gratings
(120.2130) Instrumentation, measurement, and metrology : Ellipsometry and polarimetry
(120.3940) Instrumentation, measurement, and metrology : Metrology

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: October 12, 2009
Manuscript Accepted: October 28, 2009
Published: November 6, 2009

Citation
Young-Nam Kim, Jong-Sun Paek, Silvio Rabello, Sangbong Lee, Jiangtao Hu, Zhuan Liu, Yudong Hao, and William McGahan, "Device based in-chip critical dimension and overlay metrology," Opt. Express 17, 21336-21343 (2009)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-17-23-21336


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. C. J. Raymond, “Scatterometry for Semiconductor Metrology,” Handbook of silicon semiconductor metrology, A.C. Diebold, ed., (Academic press 2001), Chap. 18, p.477–514.
  2. N. P. Smith, “Overlay metrology at the crossroads,” Proc. SPIE 6922, 0277–0286 (2008).
  3. C. Hedlund, H.-O. Blom, and S. Berg, “Microloading effect in reactive ion etching,” J. Vac. Sci. Technol. A 12(4), 1962–1965 (1994). [CrossRef]
  4. K. Rochford, “Polarization and polarimetry,” NIST publication, http://boulder.nist.gov/div815/81503_pubs/PPMDocs/Rochford-EPST-02.pdf
  5. R. W. Collins, Handbook of Ellipsometry, H. G. Tompkins and E. A. Irene, eds., (William Andrew Publishing & Springer-Verlag, 2005), Chap. 7.3.3, p 546–566.
  6. L. Li, “New formulation of the Fourier modal method for crossed surface relief gratings,” J. Opt. Soc. Am. A 14(10), 2758–2767 (1997). [CrossRef]
  7. L. Li, “Symmetries of cross-polarization diffraction coefficients of gratings,” J. Opt. Soc. Am. A 17(5), 881–887 (2000). [CrossRef]
  8. P. Vagos, J. Hu, Z. Liu, and S. Rabello, “Uncertainty and Sensitivity Analysis and its application in OCD measurements,” Proc. of SPIE 7272, 72721N–72721N–9 (2009)

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited