OSA's Digital Library

Optics Express

Optics Express

  • Editor: C. Martijn de Sterke
  • Vol. 17, Iss. 3 — Feb. 2, 2009
  • pp: 1976–1987
« Show journal navigation

On-chip spectro-detection for fully integrated coherent beam combiners

Pierre Kern, Etienne Le Coarer, and Pierre Benech  »View Author Affiliations


Optics Express, Vol. 17, Issue 3, pp. 1976-1987 (2009)
http://dx.doi.org/10.1364/OE.17.001976


View Full Text Article

Acrobat PDF (765 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

This paper presents how photonics associated with new arising detection technologies is able to provide fully integrated instrument for coherent beam combination applied to astrophysical interferometry. The feasibility and operation of on-chip coherent beam combiners has been already demonstrated using various interferometric combination schemes. More recently we proposed a new detection principle aimed at directly sampling and extracting the spectral information of an input signal together with its flux level measurement. The so-called SWIFTS demonstrated concept that stands for Stationary-Wave Integrated Fourier Transform Spectrometer, provides full spectral and spatial information recorded simultaneously thanks to a motionless detecting device. Due to some newly available detection principles considered for the implementation of the SWIFTS concept, some technologies can even provide photo-counting operation that brought a significant extension of the interferometry domain of investigation in astrophysics . The proposed concept is applicable to most of the interferometric instrumental modes including fringe tracking, fast and sensitive detection, Fourier spectral reconstruction and also to manage a large number of incoming beams. The paper presents three practical implementations, two dealing with pair-wise integrated optics beam combinations and the third one with an all-in-one 8 beam combination. In all cases the principles turned into a pair wise baseline coding after proper data processing.

© 2009 Optical Society of America

1. Introduction

While we demonstrated in the past the efficiency of photonics devices for multi beam combination in single mode interferometry [5

5. J. P. Berger, P. Haguenauer, P. Kern, K. Perraut, F. Malbet, I. Schanen, M. Severi, R. Millan-Gabet, and W. Traub, “Integrated optics for astronomical interferometry. IV. First measurements of stars,” Astron. Astrophys. Supplement series 376, L31–L34 (2001). [CrossRef]

], we show here how its association with the concept of Stationary-Wave Integrated Fourier Transform Spectrometer (SWIFTS hereafter) [6

6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

] allows us to consider a fully integrated instrument, including coherent beam combination, spectrometry and detection implemented on a single photonics device. The association of SWIFTS evanescent detection principle and photonics beam combination brings a great potential for a fully integrated beam combiner instrument.

Section 2 reminds the reader that the state of the art of the considered technologies as well as the main requirements for an interferometric beam combining instrument. According to the purposes of the considered instrument some specific requirements must be emphasized: high precision measurement of the fringe contrast, accurate phase measurements, spectral resolution capabilities, high dynamic capability on the photometric signal for the detection of faint object in the vicinity of bright stars, high imagery reconstruction capability using the largest number of telescopes, highest sensitivity to achieve observations on the fainter objects. In this section we remind the reader also of the principle of the SWIFTS concept. Section 3 describes several possible implementations of fully integrated instruments. We address for each proposed concept its adequacy the purposes of some specific instruments. We show that using existing built-in blocks, the requirements for the interferometric instrumentation can be met using a single integrated instrument.

2. Background and available technologies

2.1. Instruments for interferometry

The requirements of an interferometric instrument must be adapted according to its main purposes. An interferometric fringe pattern has two meaningful observables, its contrast, or depth of modulation and its phase or location of the central fringe.

High precision contrast measurement is required to perform an accurate reconstruction from the measured fringes, using the appropriate Fourier transform. Many instrumental biases strongly affect the fringe patterns and drastically increase the error on the reconstructed signal.

An accurate phase determination is required for both astrometric applications, and to ensure an efficient detection of the signal, while it is strongly affected by the instrumental effects and the transmission through the atmosphere. The fringe tracker instrumental mode intends to ensure close loop operation and lock the fringe position on the detector (equivalent to adaptive optics module for single dish operation). The coherencing mode dedicated to open loop operation returns the position of the whole fringe packet when the guiding star is too faint to achieve a sufficient Signal to Noise Ratio (SNR hereafter) to operate in close loop. In both modes the smallest number of pixels is required in order to optimize fastest operation on faintest sources. An accurate sampling of the fringe pattern must be done, using a sufficiently long coherence length in order to catch a shifted fringe packet. The required coherence length allows the instrument to deal with disturbing effects that induce phase jumps and fringe smearing, and with contrast losses due to longitudinal chromatism.

A fringe tracker is operated with short exposures able to drive the servo-loop at the required speed (mainly given by atmospheric characteristic time to, down to few millisecond). Coherencing mode may be operated at longer exposures time. The ultimate performances in both cases are achieved thanks to photo-counting detection that is able to deal with various temporal requirements of the incoming signal.

Spectral resolution capability is mandatory for astrophysical investigations and to provide the appropriate sampling of the foreseen spectral lines. Up to 35000 resolutions are considered in current operated instruments [7

7. D. Mourard, A. Blazit, D. Bonneau, J.-M. Clausse, F. Henault, Y. Hugues, A. Marcotto, G. Merlin, A. Roussel, P. Stee, H. McAlister, T. Brummelaar, C. Farrington, P. Goldfinger, J. Sturmann, L. Sturmann, and N. Turner, “VEGA/CHARA: a new visible spectrograph and polarimeter on the CHARA array,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

, 4

4. R. G. Petrov, F. Malbet, G. Weigelt, and P. Antonelli, “AMBER, the near-infrared spectro-interferometric three-telescope VLTI instrument,” Astron. Astrophys. 464, 1–12 (2007). [CrossRef]

]. A trade off must be done between the spectral resolution and the limiting magnitude for a given observation.

Higher complexity imagery reconstruction is ensured thanks to a larger number of baselines, for instance with a larger number of telescopes. In that case the beam combining instrument must deal with the corresponding number of beams, leading to rather complex instruments. Image reconstruction needs require also in this case to increase the number of combined telescopes and of coded baselines.

Low flux sensitivity is required for the observation of the faintest objects. It can be achieved thanks to long exposure acquisition. In this case, an associated fringe tracker is mandatory to prevent from any fringe blurring during the exposure. However the faintest sources will be distinguishable using detectors limited by the photon noise. In that case individual long exposures are no longer required.

High photometric dynamic intends to provide the detection and the analysis of faint structures in the vicinity of a bright sources (extra solar planets, surrounding disks). The detection of exo-earths requires at least a 106 flux dynamic. The higher dynamic will be achieved using photon-counting detectors limited by their photo counting rate.

Devoted designs must be chosen, according to the foreseen astrophysical science cases, but all of these specifications cannot be met with a single instrument.

2.2. Integrated optics applied to interferometry

Integrated optics (hereafter IO) developed for telecom applications is available in the 0.8 –2.4μm spectral range using various technologies. It provides very convenient toolbox is then available with suitable performances for its application to astronomical interferometry. A first review of IO capabilities applied to astronomical interferometry has been proposed ten years ago [1

1. P. Kern and F. Malbet, Astrofib’96: Integrated optics for Astronomical interferometry (1997).

]. The most interesting capability of this technology is to integrate on a single tiny chip a few centimeters long an instrument with several optical functions made of complex optical circuitry. It yields very compact instruments, and brings high instrument reliability, with a low sensitivity to external constraints such as vibrations and temperature fluctuations. The intrinsic stability of an integrated instrument induces excellent phase behaviors. Integration and maintenance operations are highly simplified, while as soon as the fiber optics connection is properly managed the main part of the instrument is self aligned.

Many convenient optical functions can be implemented on the same chip, like light deflection, beam separation and coherent combination, modulation, light dispersion [8

8. P. Kern, J.-P. Berger, P. Haguenauer, F. Malbet, and K. Perraut, “Planar Integrated Optics and astronomical interferometry,” Acad. Sci. Paris Comptes Rendus 2, 111–124 (2001). arXiv:astro-ph/0508032.

, 9

9. F. Malbet, P. Kern, I. Schanen-Duport, J.-P. Berger, K. Rousselet-Perraut, and P. Benech, “Integrated optics for astronomical interferometry. I. Concept and astronomical applications,” Astron. Astrophys. Supplement series 138, 135–145 (1999). arXiv:astro-ph/9907031. [CrossRef]

]. Furthermore, several coherent beam combination schemes are made available using single mode IO, including new schemes that are not provided by conventional bulk optics means. A description of the possible single mode IO beam combining schemes with their corresponding efficiency in terms of SNR have been proposed as a guideline for the designs of optimized components dedicated to on-going instrumental programs [10

10. J.-B. J. Lebouquin, J.-P. Berger, P. R. Labeye, E. Tatulli, F. Malbet, K. Rousselet-Perraut, and P. Y. Kern, “Comparison of integrated optics concepts for a near-infrared multi-telescope beam combiner,” in New Frontiers in Stellar Interferometry, W. A. Traub, ed., vol. 5491 of Proc. SPIE, pp. 1362-+ (2004).

]. The three main schemes that have been considered and tested are multi-axial scheme (all in one combination) using spatial coding on the detector, co-axial one (pair wise combinations) using temporal coding thanks to a modulation of the optical path difference, and a so-called co-axial ABCD concept (pair-wise combination) which provides a built-in phase coding on four outputs of the component.

An important behavior of IO components is its filtering capability while operating in single mode conditions. It allows a significant improvement of the interferometer precision, thanks to a reduction of the error on the contrast measurement [11

11. J.-B. Lebouquin, P. Labeye, F. Malbet, L. Jocou, F. Zabihian, K. Rousselet-Perraut, J.-P. Berger, A. Delboulbe, P. Kern, A. Glindemann, and M. Schöller, “Integrated optics for astronomical interferometry. VI. Coupling the light of the VLTI in K band,” Astron. Astrophys. 450, 1259–1264 (2006). [CrossRef]

, 12

12. P. Kervella, D. Ségransan, and V. Coudé du Foresto, “Data reduction methods for single-mode optical interfer-ometry. Application to the VLTI two-telescopes beam combiner VINCI,” Astron. Astrophys. 425, 1161–1174 (2004). arXiv:astro-ph/0406625. [CrossRef]

]. However it must be noticed that single mode operation limits the field of view of the interferometer to compact object observation. The field of view is limited to the diffraction pattern of the individual telescopes of the interferometric array, while the resolution of the reconstructed image is given by the length of its largest baseline.

The IO potential have been demontrated thanks to on-sky exploitation leading to astrophysical results using the IOTA interferometer (Mt Hopkins - Arizona) [2

2. S. Kraus, F. P. Schloerb, W. A. Traub, N. P. Carleton, M. Lacasse, M. Pearlman, J. D. Monnier, R. Millan-Gabet, J.-P. Berger, P. Haguenauer, K. Perraut, P. Kern, F. Malbet, and P. Labeye, “Infrared Imaging of Capella with the IOTA Closure Phase Interferometer,” Astrophys. J. 130, 246–255 (2005). arXiv:astro-ph/0504482.

, 3

3. J. D. Monnier, W. A. Traub, F. P. Schloerb, R. Millan-Gabet, J.-P. Berger, E. Pedretti, N. P. Carleton, S. Kraus, M. G. Lacasse, M. Brewer, S. Ragland, A. Ahearn, C. Coldwell, P. Haguenauer, P. Kern, P. Labeye, L. Lagny, F. Malbet, D. Malin, P. Maymounkov, S. Morel, C. Papaliolios, K. Perraut, M. Pearlman, I. L. Porro, I. Schanen, K. Souccar, G. Torres, and G. Wallace, “First Results with the IOTA3 Imaging Interferometer: The Spectroscopic Binaries λ Virginis and WR 140,” Astrophys. J. 602, L57–L60 (2004). arXiv:astro-ph/0401268. [CrossRef]

] and the VLTI. Further in progress developments consider the use of complex IO components as VSI (VLTI Spec-tro Imager) [13

13. F. Malbet, P. Kern, L. Garcia, P. J. Jocou, J.-P. Berger, D. Buscher, M. Gai, G. Weigelt, U. Beckmann, and L. Corcione, “The VLTI spectro imager,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

] and Gravity [14

14. F. Eisenhauer, “GRAVITY: getting to the event horizon of Sgr A*,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

] for the second generation instrument of the VLTI. For space borne applications, if the compactness is a trivial advantage, with a direct impact on the payload of the instrument, one may mention also the strong advantages of such integrated instrument. During the integration phases the constrains applied to the integration and alignment procedures is significantly reduced. Most of the efforts are reported during the design phase. It reduces the unreliability for the duration of these integration phases.

2.3. Stationary-Wave Integrated Fourier Transform Spectrometer principle

The Stationary-Wave Integrated Fourier Transform Spectrometer (SWIFTS), encapsulate a new concept for on-chip spectro-detection (see Fig. 1): The detection is achieved along a standing waves within a single mode waveguide by probing its evanescent field, using nano-detectors. Based on this concept a motionless device is able to probe the spectral information of the incoming signal [6

6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

]. Several implementations have been investigated.

In a first mode named SWIFTS-Lippmann (see Fig. 1 right), the light is coupled into a waveguide ended by a mirror. The standing waves form the interference pattern along the waveguide, with its central black fringe locked onto the mirror. It led to a Lippmann interferogram that starts by a black fringe. This mode gives only access to the spectra of the incoming light, like for a Fourier Transform Spectrometer.

In a second mode named SWIFTS-Gabor (see Fig. 1 left), the light is split in two equal parts thanks to a suitable IO divider or to a bulk optics beam splitter. These two parts are injected in counterpropagative scheme from the two extremities of a waveguide. In this scheme the two arms of the resulting interferometer are accurately balanced by construction in order to place the central fringe at the center of the detection zone. The resulting standing waves forms a Fourier interferogram along the guide. In this mode, in addition to the spectra of the incoming light, one has access also to its phase thanks to a measurement of the central fringe displacement with respect to the theoretical central fringe location. A design based on this mode is able to achieve interferometric metrology, thanks to a measurement of the fringe position.

In both cases each element of a set of nano-scale detectors or intermerdiate diffusing dots placed in the evanescent field extracts only a small fraction of the guided energy. The pitch of the nano detector set matches a convenient sampling of the standing wave, preferably more than 2 samples per fringe. The nano-detectors must be smaller than 1/6 of one fringe taking into account the refraction index of the propagating material. In order to maximize the signal the sampling is performed using a tiny square rather than a dot, that provides an average over its area. It turns into a contrast loss of 10% for a 1/4 pitch.

Fig. 1. SWIFTS principle description: Nanodetectors are placed in the evanescent field of the waveguide. Each detector samples a small part of the flux over a distance smaller than the fringe size. For polychromatic input light, the resulting superimposition of stationary waves led on to a Fourier interferogram sampled by the set of nanodetectors. The lower 3D artist views present the corresponding SWIFTS devices for colored entrance light and the resulting interferograms. Left: SWIFTS-gabor principle. The two coupled waves propagate in the waveguide in counter-propagative mode. The stationary waves are centered on the zero optical path difference location giving an access to the measurement of the interferogram phase.Right: SWIFTS-Lippmann principle. The forward propagating optical field coupled in the waveguide is reflected on the mirror at the waveguide end. The stationary waves are locked on the mirror leading to the so-called Lippmann interferogram starting by a black fringe .

This approach based on a detection in the evanescent field, allows proper sampling of the interferogram using small size detectors in comparison to the quarter wavelength of the guided light. It has been shown that an ideal positioning of the wires of the SWIFTS arrangement permits the spectrometer to build an interferogram using 74% of the incoming photon [6

6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

]. First prototypes provide a proper demonstration of the principle at various wavelengths. The above mentioned publication presents a measured spectrum over an 80 nm range (1.5μm –1.58μm) with a 4 nm resolution.

3. Proposed concepts

Having demonstrated the proper operation of IO coherent beam combiner [5

5. J. P. Berger, P. Haguenauer, P. Kern, K. Perraut, F. Malbet, I. Schanen, M. Severi, R. Millan-Gabet, and W. Traub, “Integrated optics for astronomical interferometry. IV. First measurements of stars,” Astron. Astrophys. Supplement series 376, L31–L34 (2001). [CrossRef]

] and of spectro-detection in the vicinity of wave guides (SWIFTS) [6

6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

], we have the required building blocks for a new beam combiner design with on-chip detection of the fringes. We propose here three possible schemes using demonstrated technologies.

3.1. Toward Photo-counting Fringe trackers

Fig. 2. Beam combiner design for a 4 telescope configuration associated with SSPD detectors. Pair wise combinations are performed in contra-propagative mode in the waveguides located along the sides of the square (red lines on the figure). The set of 70 nm large SSPD wires allows to pick up the evanescent signal of the standing waves of this SWIFTS-Gabor configuration. In the proposed concept the 16 wires led to a resolution of 8, well adapted to fringe tracker applications.

The principle of SSPD is reported in Fig. 3. A DC current polarizes a wire of superconductor material, for example Niobium Nitride (NbN), just below the superconducting critical current. The interaction with a photon induces an elevation of the local temperature and a not null resistance of the wire close to the absorption point. The current lines are diverted and the local density of current flow reaches the critical value: the wires loose their superconductivity behavior inducing a voltage peak on the dipole. Due to a thermal effect, the NbN line returns to the superconducting state in a very short time (< 1 ns) that allows to count high numbers of photons. Therefore, this detector presents demonstrated photon counting capabilities at a 1Gph/s rate with quantum efficiency as high as 50% for the visible-near IR domain. Dating of incoming events can be performed with a 20ps accuracy. One driving application of SSPD is quantum cryptography.

The NbN wires are reported on a substrate surface like sapphire. While the implementation of optical waveguides on Sapphire substrate has been demonstrated[19

19. L. Laversenne, P. Hoffmann, M. Pollnau, P. Moretti, and J. Mugnier, “Designable buried waveguides in sapphire by proton implantation,” Appl. Phys. Lett. 85, 5167-+ (2004). [CrossRef]

], it is possible to consider to report a suitable SSPD setup on an integrated optics circuit designed for a multi telescope beam combination.

Figure 2 shows a possible 4 telescope implementation. Each incoming beam is split to interfere with its the two nearest one within the optical waveguide. In the proposed scheme the standing waves are sampled using 16 nano wires leading to a resolution of 8. With 4 wires per fringe and considering an operation at 1.5μm in Sapphire (n = 1.7), the 16 wires 125nm apart lie on a 2μm length over a set of 4 fringes. The design is optimized in order to have the fringes centered on the wires array when all the optical path differences are properly compensated. This concept is able to provide the sensor of a close loop system to drive the suitable corrective delay lines. An other design has been proposed which codes all the baselines in the 4 telescope configuration using diagonal guides in the square layout. Designs for larger number of telescopes can be proposed using the corresponding polygon shape in a circle scheme that code the minimum number of baselines required for a fringe tracker in a redundant mode. The proposed concept requires specific development to obtain satisfactory behaviors of the combining waveguides at the temperature of operation of SSPD. NbN SSPD are operated at liquid Helium temperature sufficiently far from the superconductive critical temperature of the NbN film (11K), reducing the sensitivity to the operating temperature. Then SSPD are not very sensitive to temperature changes contrary to some others super conducting detectors as Transition Edge Superconducting detectors (TES) or Super conducting Tunnel Junction (STJ). An extension of this design can be considered using other nanodetectors like QDIP (Quantum Dot Infrared Detector) for example or with new high temperature superconducting materials such YBaCuO which allow 77 K operation.

Fig. 3. Principe of the SSPD concept according to [17]. Four states of a SSPD when a photon hits the superconducting materials where a subcritic current is installed: (a) The photon is absorbed and heat locally the material. (b) The material is locally over the critical temperature inducing a larger resistivity. The current lines are deviated and the density of current (c) becomes over the superconducting limit (d) Current is temporaly stopped and the heat is dissipated in the substrate and the line becomes again superconductive. (e) All SSPD wires are placed in the evanescent field of the waveguides (red strip of the figure). The photons can disrupt any wires according to the intensity of the interferogram at crossing location.

Suitable modeling using Rigorous Coupled-Wave Analysis (RCWA) [20

20. A. Morand, G. Custillon, P. Benech, E. Le Coarer, G. Leblond, and S. Blaize, “Compact spectrometer modeling based on wavelength-scale stationary wave Fourier transform in integrated optic,” vol. 6996, p. 69960M (SPIE, 2008). URL http://link.aip.org/link/?PSI/6996/69960M/1.

] shows that a global detecting efficiency of 30% is achievable in such a case. In these conditions considering the beam combination of 2 × 8m telescope ( VLTi ) and a SNR of 3, we calculate that fringe tracking can be performed at 1kHz rate for a stellar magnitude K=14 (Stellar magnitude for the astronomical photometric K band (2μm – 2.4μm). The photo counting mode brings even faster operation. It brings also the capability to deal with a very high dynamic of the incoming flux, mainly limited by the maximum speed of the detector electronics.

This technology is well suited for fringe tracker applications where only a limited number of sampling point is required to sense the phase of the interferometric signal. It led to a SWIFTS-Gabor concept with only a limited number of nano-wires. It potentially provides photo-counting capability at very high speed. The photon counting process at very high speed ensures also a sampling of the incoming flux over an extended photometric dynamic.

Current SSPD developments in progress in a LAOG-CEA collaboration aims at preparing elementary built-in blocks of such a concept.

3.2. Toward an integrated instrument with high spectral resolution capability

For this setup (see Fig. 4) we propose a modified design of an existing chip dedicated to the combination of the beams coming from 4 telescopes in matrix mode in the near infrared [21

21. L. Jocou, J.-P. Berger, F. Malbet, and P. Kern, “System overview of the VLTI Spectro-Image,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

,22

22. S. Lacour, L. Jocou, T. Moulin, P. Labeye, M. Benisty, J.-P. Berger, A. Delboube, P. Kern, X. Haubois, E. Her-wawts, F. Malbet, K. Perraut, and G. Perrin, “Characterization of integrated optics components for the second generation of VLTI instruments,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

]. In this design the optical layout provides on its outputs a set of 4 phases status without any temporal modulation , which allows the proper sampling of the interference pattern. The sampling of all available baselines lead to a 24 output chip.

Fig. 4. A 4 telescope beam combiner implementation using conventional FPA. Each output of this pair wise beam combiner is sampled within an enlarged guiding area. All enlarged guide ends with a tilted mirror surface that induces a tilted SWIFTS-Lippmann interferogram. A set of parallel nano-metric wires pick up a part of the signal in the evanescent field of the planar guide.

For all output guides, we propose to implement an enlarged waveguide zone ended by a slightly tilted integrated mirror. This mirror induces tilted standing waves in the enlarged zone where a set of nano-wires picks up the evanescent field above the wave-guides. An IR Focal Plane Array (FPA hereafter) is mounted beneath this enlarged zone performing the detection of the SWIFTS-Lippmann fringes able to measure the output spectrum at each channel output. The FPA pixel lines are located in coincidence with the wire arrangement. The resulting standing waves in the near IR (λ = 1.5μm,and n = 1.5) present a wavelength of 500nm, leading to an undersampling using 18.5μm pixels. The proper sampling will be performed as soon as the enlarged guide width is sampled by 74 pixels, as each pixel line is surrounding 37 fringes.

This configuration is well-suited for high spectral resolutions since this one is given by the length of the enlarged zone surrounded by the FPA. For example an Hawaii2 FPA with a line of 1024×18.5μm pixel provides a spectral resolution of R=40 000 at 1.5μm (e.g. 0.04 nm). Among the proposed concepts in this paper, it is certainly the cleanest one while it provides an accurate measurement over all the baselines with an identical number of samples. Such design can be implemented using modified available IO components associated with commercial FPA, bounded with the suitable nano-wire comb thanks to available technology platform.

Fig. 5. Simulation for a Fizeau-Narcisse configuration for an 8 T beam combiner. The upper part shows the SWIFTS-Gabor pattern (holographic pattern) in the planar waveguide fed by 8 incoming waveguides. The lower part corresponds to its Fourier transform, giving the power spectra along all available baselines. The middle part corresponds to the monochromatic case (c, d), while the right and left part corresponds to three chromatic bands (150nm wide) covering the visible domain that illustrates the chromatic behavior of the compo-nent(a, b, e, f). One baseline (2 inputs) built up a fringe pattern that corresponds in the Fourier plane to a set of two fringe peaks in the monochromatic case (shown by the green arrow of the figure) or two symmetrical spectra in the polychromatic case. The blue arrows show the individual spectrum directions. (a) and (b): The waveguide inputs pointed by the white arrows are regularly disposed around the circular beam combining planar waveguide. The corresponding Fourier transform illustrates how the spectra overlap inducing an information confusion (see Fig. 6) (c) (d) (e) and (f): The waveguide inputs are managed in a non-redondant arrangement to avoid any overlapping of the resulting pairwise spectra.

Using the assumptions of section 3.1, one can derive the achievable sensitivity of an instrument based on this concept. It has been demonstrated [6

6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

] that a set of nano wires properly designed is able to extract up to 74% of the incoming signal for an optimized setup. A FPA mounted in front of these wires is able to detect half part of the diffused light, leading to a 37% efficiency. In a near future one can consider to use a close to noiseless IR detector [23

23. J. Rothman, G. Perrais, P. Ballet, L. Mollard, S. Gout, and J.-P. Chamonal, “Latest Developments of HgCdTe e-APDs at CEA LETI-Minatec,” Journal of Electronic Materials 37, 1303–1310 (2008). [CrossRef]

], bounded on the above described near IR IO beam combiner. Under conservative assumptions one may consider that the foreseen IO combining component present an efficiency of 30%. Considering a resolution of 40 000 over 4 outputs with an exposure time up to 120s, using a SNR of 10, such an instrument will be able to attain a theoretical stellar magnitude K = 14.3.

A similar development for spectroscopy purposes in an other spectral range, using an arrangement of parallel straight waveguides is currently under progress by the authors funded by a FUI program of the French government (see Acknowledgments). The adaptation for the applications to interferometry requires the use of a suitable IO beam combiner.

Fig. 6. Implementation of the Extended Planar Concept. A proper arrangement of gold nano-dot is implemented on the planar wave guide fed by the tapered input waveguides. This IO component is directly mounted on a FPA, with a pixel corresponding to each diffusing dot.

3.3. Extended Planar concept

A matrix of nano-dots spread out the light from the resulting SWIFTS-Gabor fringes, collected by the pixels of a near IR FPA bounded at the waveguide surface (see Fig. 6).

The pixel pitch of available FPA (around 20 μm for near IR HgCdTe detectors) induces an under-sampling condition while the fringe width inside the waveguide material is almost 500 nm at 1.5μm. To ensure proper complete sampling of the SWIFTS-Gabor pattern it is considered either to modulate the Optical Path Difference for all baselines, or to take benefit of the high redundancy available in the resulting interferometric pattern. The efficiency performances of this setup will be given by the performances of the associated FPA.

4. Conclusion

In this paper we propose some possible implementation of SWIFTS-based coherent beam combiners, for single mode interferometry, using technologies which are available or under development. Such promising integrated instruments may provide both compact setups with all deriving behaviors. Furthermore the concept provides optimized performances as it is possible to consider adapted designs according to the foreseen instrumental and astrophysical application. The design allows to meet most of the design requirements for an instrument dedicated to stellar interferometry.

The single mode operation and the compactness of an integrated instrument ensures the measurement precision. On-chip detection ensures accurate and intrinsically stable sampling of the fringe patterns and provides an efficient phase measurement. Some possible concepts are able to manage a large number of sampling points opening the way to high spectral resolution and to large number of telescopes beam combination. The possibility of implementing a photo counting detection allows to consider high photometric sensitivity and high photometric dynamic together with high speed operation.

The introduction of SWIFTS concept, opens the way for the design of fully integrated interferometric instruments that include sophisticated functions such as phase modulation, junctions, switches , spectrometry and detection. Even if other photonics spectrometer concepts can also be envisaged to improve the signal to noise of such instruments, due to its intrinsic simplicity only SWIFTS based concept are currently under development for an application to astrophysical interferometry.

Acknowledgments

This work has been supported thanks to CNES funding. A support was also alocated to the project by the ASHRA / INSU from CNRS. On going SWIFTS developments are led by Thierry Gonthiez (Floralis / http://floralis.fr/us/), mainly for the program labeled by the global competitiveness cluster MINALOGIC and funded through the national french FUI program (Fonds Unique Interministériel). The authors would like to thanks Jean Philippe Berger and Fabien Malbet for their fruitful remarks on this manuscript. SSPD developments are conducted by Philippe Feautrier at LAOG together with Jean Claude Villégier at CEA-Grenoble.

References and links

1.

P. Kern and F. Malbet, Astrofib’96: Integrated optics for Astronomical interferometry (1997).

2.

S. Kraus, F. P. Schloerb, W. A. Traub, N. P. Carleton, M. Lacasse, M. Pearlman, J. D. Monnier, R. Millan-Gabet, J.-P. Berger, P. Haguenauer, K. Perraut, P. Kern, F. Malbet, and P. Labeye, “Infrared Imaging of Capella with the IOTA Closure Phase Interferometer,” Astrophys. J. 130, 246–255 (2005). arXiv:astro-ph/0504482.

3.

J. D. Monnier, W. A. Traub, F. P. Schloerb, R. Millan-Gabet, J.-P. Berger, E. Pedretti, N. P. Carleton, S. Kraus, M. G. Lacasse, M. Brewer, S. Ragland, A. Ahearn, C. Coldwell, P. Haguenauer, P. Kern, P. Labeye, L. Lagny, F. Malbet, D. Malin, P. Maymounkov, S. Morel, C. Papaliolios, K. Perraut, M. Pearlman, I. L. Porro, I. Schanen, K. Souccar, G. Torres, and G. Wallace, “First Results with the IOTA3 Imaging Interferometer: The Spectroscopic Binaries λ Virginis and WR 140,” Astrophys. J. 602, L57–L60 (2004). arXiv:astro-ph/0401268. [CrossRef]

4.

R. G. Petrov, F. Malbet, G. Weigelt, and P. Antonelli, “AMBER, the near-infrared spectro-interferometric three-telescope VLTI instrument,” Astron. Astrophys. 464, 1–12 (2007). [CrossRef]

5.

J. P. Berger, P. Haguenauer, P. Kern, K. Perraut, F. Malbet, I. Schanen, M. Severi, R. Millan-Gabet, and W. Traub, “Integrated optics for astronomical interferometry. IV. First measurements of stars,” Astron. Astrophys. Supplement series 376, L31–L34 (2001). [CrossRef]

6.

E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. Lérondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, “Wavelength-scale stationary-wave integrated Fourier-transform spectrometry,” Nature Photonics 1, 473–478 (2007). arXiv:0708.0272. [CrossRef]

7.

D. Mourard, A. Blazit, D. Bonneau, J.-M. Clausse, F. Henault, Y. Hugues, A. Marcotto, G. Merlin, A. Roussel, P. Stee, H. McAlister, T. Brummelaar, C. Farrington, P. Goldfinger, J. Sturmann, L. Sturmann, and N. Turner, “VEGA/CHARA: a new visible spectrograph and polarimeter on the CHARA array,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

8.

P. Kern, J.-P. Berger, P. Haguenauer, F. Malbet, and K. Perraut, “Planar Integrated Optics and astronomical interferometry,” Acad. Sci. Paris Comptes Rendus 2, 111–124 (2001). arXiv:astro-ph/0508032.

9.

F. Malbet, P. Kern, I. Schanen-Duport, J.-P. Berger, K. Rousselet-Perraut, and P. Benech, “Integrated optics for astronomical interferometry. I. Concept and astronomical applications,” Astron. Astrophys. Supplement series 138, 135–145 (1999). arXiv:astro-ph/9907031. [CrossRef]

10.

J.-B. J. Lebouquin, J.-P. Berger, P. R. Labeye, E. Tatulli, F. Malbet, K. Rousselet-Perraut, and P. Y. Kern, “Comparison of integrated optics concepts for a near-infrared multi-telescope beam combiner,” in New Frontiers in Stellar Interferometry, W. A. Traub, ed., vol. 5491 of Proc. SPIE, pp. 1362-+ (2004).

11.

J.-B. Lebouquin, P. Labeye, F. Malbet, L. Jocou, F. Zabihian, K. Rousselet-Perraut, J.-P. Berger, A. Delboulbe, P. Kern, A. Glindemann, and M. Schöller, “Integrated optics for astronomical interferometry. VI. Coupling the light of the VLTI in K band,” Astron. Astrophys. 450, 1259–1264 (2006). [CrossRef]

12.

P. Kervella, D. Ségransan, and V. Coudé du Foresto, “Data reduction methods for single-mode optical interfer-ometry. Application to the VLTI two-telescopes beam combiner VINCI,” Astron. Astrophys. 425, 1161–1174 (2004). arXiv:astro-ph/0406625. [CrossRef]

13.

F. Malbet, P. Kern, L. Garcia, P. J. Jocou, J.-P. Berger, D. Buscher, M. Gai, G. Weigelt, U. Beckmann, and L. Corcione, “The VLTI spectro imager,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

14.

F. Eisenhauer, “GRAVITY: getting to the event horizon of Sgr A*,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

15.

P. R. Lawson, O. P. Lay, S. R. Martin, R. D. Peters, R. O. Gappinger, A. Ksendzov, D. P. Scharf, A. J. Booth, C. A. Beichman, E. Serabyn, K. J. Johnston, and W. C. Danchi, “Terrestrial Planet Finder Interferometer: 2007-2008 progress and plans,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

16.

O. Wallner, K. Ergenzinger, and U. Johann, “Terrestrial exo-planet science by nulling interferometry: instrument design and scientific performance,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

17.

A. Verevkin, J. Zhang, R. Sobolewski, A. Lipatov, O. Okunev, G. Chulkova, A. Korneev, K. Smirnov, G. N. Gol’tsman, and A. Semenov, “Detection efficiency of large-active-area NbN single-photon superconducting detectors in the ultraviolet to near-infrared range,” Appl. Phys. Lett. 80, 4687–4689 (2002). [CrossRef]

18.

P. Feautrier, E. le Coarer, R. E. de Lamaestre, P. Cavalier, L. Maingault, J.-C. Villégier, L. Frey, J. Claudon, N. Bergeard, M. Tarkhov, and J.-P. Poizat, “High-speed superconducting single photon detectors for innovative astronomical applications,” J. Phys. : Conference Series 97, 012,087 (9pp) (2008). URLhttp://stacks.iop.org/1742-6596/97/012087. [CrossRef]

19.

L. Laversenne, P. Hoffmann, M. Pollnau, P. Moretti, and J. Mugnier, “Designable buried waveguides in sapphire by proton implantation,” Appl. Phys. Lett. 85, 5167-+ (2004). [CrossRef]

20.

A. Morand, G. Custillon, P. Benech, E. Le Coarer, G. Leblond, and S. Blaize, “Compact spectrometer modeling based on wavelength-scale stationary wave Fourier transform in integrated optic,” vol. 6996, p. 69960M (SPIE, 2008). URL http://link.aip.org/link/?PSI/6996/69960M/1.

21.

L. Jocou, J.-P. Berger, F. Malbet, and P. Kern, “System overview of the VLTI Spectro-Image,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

22.

S. Lacour, L. Jocou, T. Moulin, P. Labeye, M. Benisty, J.-P. Berger, A. Delboube, P. Kern, X. Haubois, E. Her-wawts, F. Malbet, K. Perraut, and G. Perrin, “Characterization of integrated optics components for the second generation of VLTI instruments,” in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).

23.

J. Rothman, G. Perrais, P. Ballet, L. Mollard, S. Gout, and J.-P. Chamonal, “Latest Developments of HgCdTe e-APDs at CEA LETI-Minatec,” Journal of Electronic Materials 37, 1303–1310 (2008). [CrossRef]

OCIS Codes
(040.1880) Detectors : Detection
(070.0070) Fourier optics and signal processing : Fourier optics and signal processing
(120.3180) Instrumentation, measurement, and metrology : Interferometry
(130.3120) Integrated optics : Integrated optics devices
(130.6750) Integrated optics : Systems

History
Original Manuscript: October 22, 2008
Revised Manuscript: November 28, 2008
Manuscript Accepted: December 1, 2008
Published: January 30, 2009

Virtual Issues
Focus Issue: Astrophotonics (2009) Optics Express

Citation
Pierre Kern, Etienne Le Coärer, and Pierre Benech, "On-chip spectro-detection for fully integrated coherent beam combiners," Opt. Express 17, 1976-1987 (2009)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-17-3-1976


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. P. Kern and F. Malbet, Astrofib’96: Integrated optics for Astronomical interferometry (1997).
  2. S. Kraus, F. P. Schloerb, W. A. Traub, N. P. Carleton, M. Lacasse, M. Pearlman, J. D. Monnier, R. Millan-Gabet, J.-P. Berger, P. Haguenauer, K. Perraut, P. Kern, F. Malbet, and P. Labeye, "Infrared Imaging of Capella with the IOTA Closure Phase Interferometer," Astrophys. J. 130, 246-255 (2005). arXiv:astro-ph/0504482.
  3. J. D. Monnier, W. A. Traub, F. P. Schloerb, R. Millan-Gabet, J.-P. Berger, E. Pedretti, N. P. Carleton, S. Kraus, M. G. Lacasse, M. Brewer, S. Ragland, A. Ahearn, C. Coldwell, P. Haguenauer, P. Kern, P. Labeye, L. Lagny, F. Malbet, D. Malin, P. Maymounkov, S. Morel, C. Papaliolios, K. Perraut, M. Pearlman, I. L. Porro, I. Schanen, K. Souccar, G. Torres, and G. Wallace, "First Results with the IOTA3 Imaging Interferometer: The Spectroscopic Binaries ⌊ Virginis and WR 140," Astrophys. J. 602, L57-L60 (2004). arXiv:astro-ph/0401268. [CrossRef]
  4. R. G. Petrov, F. Malbet, G. Weigelt, and P. Antonelli, "AMBER, the near-infrared spectro-interferometric threetelescope VLTI instrument," Astron. Astrophys. 464, 1-12 (2007). [CrossRef]
  5. J. P. Berger, P. Haguenauer, P. Kern, K. Perraut, F. Malbet, I. Schanen, M. Severi, R. Millan-Gabet, andW. Traub, "Integrated optics for astronomical interferometry. IV. First measurements of stars," Astron. Astrophys. Supplement series 376, L31-L34 (2001). [CrossRef]
  6. E. Le Coarer, S. Blaize, P. Benech, I. Stefanon, A. Morand, G. L’erondel, G. Leblond, P. Kern, J. M. Fedeli, and P. Royer, "Wavelength-scale stationary-wave integrated Fourier-transform spectrometry," Nature Photonics 1, 473-478 (2007). arXiv:0708.0272. [CrossRef]
  7. D. Mourard, A. Blazit, D. Bonneau, J.-M. Clausse, F. Henault, Y. Hugues, A. Marcotto, G. Merlin, A. Roussel, P. Stee, H. McAlister, T. Brummelaar, C. Farrington, P. Goldfinger, J. Sturmann, L. Sturmann, and N. Turner, " VEGA/CHARA: a new visible spectrograph and polarimeter on the CHARA array, " in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  8. P. Kern, J.-P. Berger, P. Haguenauer, F. Malbet, and K. Perraut, "Planar Integrated Optics and astronomical interferometry," Acad. Sci. Paris Comptes Rendus 2, 111-124 (2001). arXiv:astro-ph/0508032.
  9. F. Malbet, P. Kern, I. Schanen-Duport, J.-P. Berger, K. Rousselet-Perraut, and P. Benech, "Integrated optics for astronomical interferometry. I. Concept and astronomical applications," Astron. Astrophys. Supplement series 138, 135-145 (1999). arXiv:astro-ph/9907031. [CrossRef]
  10. J.-B. J. Lebouquin, J.-P. Berger, P. R. Labeye, E. Tatulli, F. Malbet, K. Rousselet-Perraut, and P. Y. Kern, "Comparison of integrated optics concepts for a near-infrared multi-telescope beam combiner," in New Frontiers in Stellar Interferometry, W. A. Traub, ed., vol. 5491 of Proc. SPIE, pp. 1362-+ (2004).
  11. J.-B. Lebouquin, P. Labeye, F. Malbet, L. Jocou, F. Zabihian, K. Rousselet-Perraut, J.-P. Berger, A. Delboulb’e, P. Kern, A. Glindemann, and M. Sch¨oller, "Integrated optics for astronomical interferometry. VI. Coupling the light of the VLTI in K band," Astron. Astrophys. 450, 1259-1264 (2006). [CrossRef]
  12. P. Kervella, D. S’egransan, and V. Coud’e du Foresto, "Data reduction methods for single-mode optical interferometry. Application to the VLTI two-telescopes beam combiner VINCI," Astron. Astrophys. 425, 1161-1174 (2004). arXiv:astro-ph/0406625. [CrossRef]
  13. F. Malbet, P. Kern, L. Garcia, P. J. Jocou, J.-P. Berger, D., Buscher, M. Gai, G. Weigelt, U. Beckmann, and L. Corcione, "The VLTI spectro imager," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  14. F. Eisenhauer, "GRAVITY: getting to the event horizon of Sgr A*," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  15. P. R. Lawson, O. P. Lay, S. R. Martin, R. D. Peters, R. O. Gappinger, A. Ksendzov, D. P. Scharf, A. J. Booth, C. A. Beichman, E. Serabyn, K. J. Johnston, and W. C. Danchi, "Terrestrial Planet Finder Interferometer: 2007-2008 progress and plans," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  16. O. Wallner, K. Ergenzinger, and U. Johann, "Terrestrial exo-planet science by nulling interferometry: instrument design and scientific performance," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  17. A. Verevkin, J. Zhang, R. Sobolewski, A. Lipatov, O. Okunev, G. Chulkova, A. Korneev, K. Smirnov, G. N. Gol’tsman, and A. Semenov, "Detection efficiency of large-active-area NbN single-photon superconducting detectors in the ultraviolet to near-infrared range," Appl. Phys. Lett. 80, 4687-4689 (2002). [CrossRef]
  18. P. Feautrier, E. le Coarer, R. E. de Lamaestre, P. Cavalier, L. Maingault, J.-C. Vill’egier, L. Frey, J. Claudon, N. Bergeard, M. Tarkhov, and J.-P. Poizat, "High-speed superconducting single photon detectors for innovative astronomical applications," J. Phys. : Conference Series 97, 012,087 (9pp) (2008). URL http://stacks.iop.org/1742-6596/97/012087. [CrossRef]
  19. L. Laversenne, P. Hoffmann, M. Pollnau, P. Moretti, and J. Mugnier, "Designable buried waveguides in sapphire by proton implantation," Appl. Phys. Lett. 85, 5167-+ (2004). [CrossRef]
  20. A. Morand, G. Custillon, P. Benech, E. Le Coarer, G. Leblond, and S. Blaize, "Compact spectrometer modeling based on wavelength-scale stationary wave Fourier transform in integrated optic," vol. 6996, p. 69960M (SPIE, 2008). URL http://link.aip.org/link/?PSI/6996/69960M/1.
  21. L. Jocou, J.-P. Berger, F., Malbet, and P. Kern, "System overview of the VLTI Spectro-Image," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  22. S. Lacour, L. Jocou, T. Moulin, P. Labeye, M. Benisty, J.-P. Berger, A. Delboube, P. Kern, X. Haubois, E. Herwawts, F. Malbet, K. Perraut, and G. Perrin, " Characterization of integrated optics components for the second generation of VLTI instruments," in Optical and Infrared Interferometry, vol. 7013 of Proc. SPIE (2008).
  23. J. Rothman, G. Perrais, P. Ballet, L. Mollard, S. Gout, and J.-P. Chamonal, "Latest Developments of HgCdTe e-APDs at CEA LETI-Minatec," Journal of Electronic Materials 37, 1303-1310 (2008). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited