A systematic method for designing depth-fused multi-focal plane three-dimensional displays

Sheng Liu and Hong Hua  »View Author Affiliations


Optics Express, Vol. 18, Issue 11, pp. 11562-11573 (2010)
http://dx.doi.org/10.1364/OE.18.011562


View Full Text Article

Acrobat PDF (1953 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Lack of accurate focus cues in conventional stereoscopic displays has potentially significant effects on depth perception accuracy and visual fatigue. Recently several multi-focal plane display prototypes have been demonstrated with the promise of improving the accuracy of focus cue rendering in stereoscopic displays. In this paper, we present a systematic method to address two fundamental issues in designing a multi-focal plane display: (1) the appropriate dioptric spacing between adjacent focal planes; and (2) the depth-weighted fusing function to render a continuous three-dimensional (3-D) volume using a sparse number of focal planes placed in the space. By taking account of both ocular factors of the human visual system (HVS) and display factors of a multi-focal plane system, we determine that an appropriate spacing between two adjacent focal planes should be ~0.6 diopter (D) while a smaller spacing may be necessary for further improving retinal image quality. We further develop a set of nonlinear depth-weighted fusing function with the promise of balancing perceptual continuity of a 3-D scene and retinal image quality. Our method was based on quantitative evaluation of the modulation transfer functions (MTF) of depth-fused images formed on retina.

© 2010 OSA

1. Introduction

Stereoscopic displays have found numerous applications, spanning the fields of scientific visualization, training and simulation, cinema, and home entertainment systems. Although conventional stereoscopic displays can render pictorial and binocular disparity cues fairly well and thus create compelling depth perceptions, they suffer the drawbacks of vergence accommodation conflict [1

1. J. P. Wann, S. Rushton, and M. Mon-Williams, “Natural problems for stereoscopic depth perception in virtual environments,” Vision Res. 35(19), 2731–2736 (1995). [CrossRef] [PubMed]

,2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

], distorted depth perception [3

3. S. J. Watt, K. Akeley, M. O. Ernst, and M. S. Banks, “Focus cues affect perceived depth,” J. Vis. 5(10), 834–862 (2005). [CrossRef]

], and visual fatigue [4

4. M. Mon-Williams, J. P. Warm, and S. Rushton, “Binocular vision in a virtual world: visual deficits following the wearing of a head-mounted display,” Ophthalmic Physiol. Opt. 13(4), 387–391 (1993). [CrossRef] [PubMed]

]. Several alternative technologies may potentially overcome these drawbacks, including holographic displays [5

5. J. F. Heanue, M. C. Bashaw, and L. Hesselink, “Volume holographic storage and retrieval of digital data,” Science 265(5173), 749–752 (1994). [CrossRef] [PubMed]

], volumetric displays [6

6. G. E. Favalora, J. Napoli, D. M. Hall, R. K. Dorval, M. G. Giovinco, M. J. Richmond, and W. S. Chun, “100 million-voxel volumetric display,” Proc. SPIE 4712, 300–312 (2002). [CrossRef]

8

8. A. Jones, I. McDowall, H. Yamada, M. Bolas, and P. Debevec, “Rendering for an interactive 360° light field display,” ACM Trans. Graph. 26, 40–1–40–10 (2007).

], and multi-focal plane displays [9

9. J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]

16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

]. Among those technologies, multi-focal plane three-dimensional (3-D) displays leverage computational power, accuracy on depth perception, and conventional two-dimensional (2-D) display technologies.

Different from conventional stereoscopic displays where stereoscopic image pairs are rendered on 2-D flat surfaces at a single fixed focal distance from the eye, a multi-focal plane display consists of a series of carefully placed focal planes at discrete focal distances. These discrete focal planes sample a 3-D scene volume into multiple zones along the visual axis. Objects contained within a zone are rendered on a corresponding pair of adjacent focal planes. Multi-focal plane displays may be implemented either by spatially multiplexing a stack of 2-D displays [9

9. J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]

12

12. C. Lee, S. Diverdi, and T. Höllerer, “Depth-fused 3D imagery on an immaterial display,” IEEE Trans. Vis. Comput. Graph. 15(1), 20–33 (2009). [CrossRef]

] in the visual space or by fast switching the focal distance of a single 2-D display in synchronization with the frame rendering of multi-focal images [13

13. S. Suyama, M. Date, and H. Takada, “Three-dimensional display system with dual frequency liquid crystal varifocal lens,” Jpn. J. Appl. Phys. 39(Part 1, No. 2A), 480–484 (2000). [CrossRef]

16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

].

Although the emergence of multi-focal plane displays have demonstrated promising potentials for reducing the visual artifacts to various extents [2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

,3

3. S. J. Watt, K. Akeley, M. O. Ernst, and M. S. Banks, “Focus cues affect perceived depth,” J. Vis. 5(10), 834–862 (2005). [CrossRef]

,10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

12

12. C. Lee, S. Diverdi, and T. Höllerer, “Depth-fused 3D imagery on an immaterial display,” IEEE Trans. Vis. Comput. Graph. 15(1), 20–33 (2009). [CrossRef]

,15

15. S. Liu and H. Hua, “Time-multiplexed dual-focal plane head-mounted display with a liquid lens,” Opt. Lett. 34(11), 1642–1644 (2009). [CrossRef] [PubMed]

,16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

], there have been relatively few systematic investigations on the optical design and image quality assessment of such displays. There are two fundamental issues that need to be addressed—(1) the optimal dioptric spacing between adjacent focal planes to produce acceptable image quality and depth resolution, which essentially determines the number of focal planes necessary for creating a multi-focal plane display to cover a given volumetric space; and (2) a method to render correct or near-correct focus cues for a continuous scene volume through a finite number of sparsely-spaced focal planes without creating noticeable depth aliasing effect and depth discontinuity. Several pioneering work addressed some of these issues from different aspects. For instance, in a theoretical work Rolland et al. suggested that the spacing between adjacent focal planes should be a constant dioptric distance of 1/7 diopter (D) and 14 focal planes are needed to cover the depth range from 0D to 2D [9

9. J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]

]; Akeley et al. demonstrated a three-focal plane display prototype by optically combining three 2-D displays through beamsplitters which creates a constant dioptric separation of 0.67D for adjacent focal planes [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

]; Liu and Hua presented a dual-focal plane display prototype with addressable focal distances throughout a volumetric space from 8D to 0D enabled by a liquid lens device [15

15. S. Liu and H. Hua, “Time-multiplexed dual-focal plane head-mounted display with a liquid lens,” Opt. Lett. 34(11), 1642–1644 (2009). [CrossRef] [PubMed]

]; Love et al. recently developed a four-focal plane prototype with discretely addressable focal planes enabled by birefringence lenses [16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

]; and Lee et al. demonstrated an immaterial two-focal plane display with the two image planes configured in an L-shape [12

12. C. Lee, S. Diverdi, and T. Höllerer, “Depth-fused 3D imagery on an immaterial display,” IEEE Trans. Vis. Comput. Graph. 15(1), 20–33 (2009). [CrossRef]

].

A large number of focal planes and small dioptric spacing are desirable for improving image quality and reducing perceptual effects in multi-focal plane displays. On the other hand, it is practically very challenging to achieve a large number of focal planes with the affordance of current technologies. In order to reduce the number of necessary focal planes to a manageable level, a depth-weighted blending technique may be implemented. Such method leads to a depth-fused 3-D (DFD) perception [11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

], where two overlapped images displayed on two transparent screens at two different depths may be perceived as a single-depth image. In addition, the luminance ratio between the two images may be modulated to change the perceived depth of the fused image. Hereafter multi-focal plane technologies that incorporate the DFD effect are referred to as depth-fused multi-focal plane displays, or DFD displays.

Due to the lack of a systematic quality metrics, in existing DFD displays, the choice of the spacing between adjacent focal planes differ significantly, ranging from 0.028D [11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

] to 0.67D [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

]. Furthermore, a linear form of depth-weighted fusing function was mainly adopted in existing DFD prototypes [2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

,10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

,11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

,16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

], with few considerations of optimizing the function form to account for key ocular factors of the human visual system (HVS). Hoffman et al. [2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

] investigated the retinal image quality in a three-focal plane DFD display prototype. The contrast modulation of the retinal images was found to be affected by pupil size, ocular aberrations, and target spatial frequency.

In this paper, we present a systematic approach to address the two aforementioned fundamental issues in designing a depth-fused multi-focal plane display. Our method is based on quantitative evaluation of the modulation transfer functions (MTF) of the DFD images formed on the retina. It takes into account most of the ocular factors, such as pupil size, monochromatic and chromatic aberrations, diffraction, Stiles-Crawford effect (SCE) [17

17. W. S. Stiles and B. H. Crawford, “The luminous efficiency of rays entering the eye pupil at different points,” Proc. R. Soc. Lond., B 112(778), 428–450 (1933). [CrossRef]

], and accommodation, and display factors, such as dioptric midpoint, dioptric spacing, depth filter, and spatial frequency of the target. Based on the MTFs of the retinal images of a DFD display and the depth of field (DOF) of the human visual system under photopic viewing conditions, we determine the optimal arrangement of the focal planes and characterize the depth-weighted fusing function between adjacent focal planes. In Section 2, we describe the generalized DFD display method. In Section 3, the simulation models and methods to predict the retinal image quality, or MTF, of a DFD display is described. In Section 4, we present the simulation results that investigated the effects of various display factors on retinal image quality and suggest guidelines for optimizing a DFD display design. Finally in Section 5, we simulate retinal images and MTFs of DFD displays using our proposed methods and compare to those generated by the prior methods.

2. Generalized DFD display method

Figure 1
Fig. 1 Schematic model of a depth fused dual-focal plane display. Pixels on the front (A) and back (B) focal planes are located at z 1 and z 2 respectively from the eye, and the fused pixel (C) is located at z (z 2<z<z 1). All distances are defined in dioptric units.
illustrates the depth fusion concept of two images displayed on two adjacent focal planes separated by a dioptric distance of Δz. The dioptric distance from the eye to the front focal plane is z 1 and to the rear plane is z 2. When the images shown on the two-layer displays are aligned such that each pixel on the front and rear planes subtends the same visual angle to the eye, the front and back pixels (e.g. A and B, respectively) are then viewed as completely overlapped at the viewpoint and fused as a single pixel (e.g. C). The luminance of the fused pixel (L) is summed from the front and rear pixels (L 1 and L 2, respectively), and the luminance distribution between the front and back pixels is weighted by the rendered depth z of the fused pixel. These relationships may be expressed as:
L=L1(z)+L2(z)=w1(z)L+w2(z)L,
(1)
where w 1(z) and w 2(z) are the depth-weighted fusing functions modulating the luminance of the front and back focal planes, respectively. Typically w 1(z) + w 2(z) = 1 is enforced such that the luminance of the fused pixel is L 1 when w 1(z) = 1 and is L 2 when w 2(z) = 1. We hereafter assume the peak luminance of individual focal planes is normalized to be uniform, without considering system-specific optical losses potentially in some forms of multi-focal plane displays (e.g. in spatially multiplexed displays where light may be projected through a thick stack of display panels). Optical losses of a system should be characterized to normalize non-uniformity across the viewing volume before applying depth-weighted fusing functions.

Depth-fused 3-D perception effect indicates [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

,11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

], as the depth-weighted fusing functions (w 1 and w 2) change, the perceived depth z^ of the fused pixel will change accordingly, formulated as:

z^=f(w1,w2).
(2)

For instance, when w 1(z) = 1, the perceived depth should be z 1, and vice versa is z 2 when w 2(z) = 1.

In a generalized n-focal plane DFD system, the dioptric distances from the eye to the n-focal planes are denoted as z 1, z 2, ….z n in distance order where z 1 is the closest one to the eye. We assume that the 3-D scenes contained between a pair of adjacent focal planes are rendered only on this corresponding focal plane pair. Under this assumption, a given focal plane at z i will render all the 3-D scenes contained between the (i-1)th and the (i + 1)th focal planes. Within the depth range of z i-1zz i + 1, many scene points may be projected onto the same pixel of the i th focal plane, among which only the closest scene point to the eye is un-occluded and thus effectively determines the depth-weighted fusing function modulating the luminance of the specific pixel. The closest scene point corresponding to a specific pixel can typically be retrieved from the z-buffer in computer graphics renderer [18

18. G. Riguer, N. Tatarchuk, and J. Isidoro, ShaderX2: Shader Programming Tips and Tricks with DirectX 9, (Wordware, 2003).

]. Let us assume the depth of the closest 3-D scene point projected onto a given pixel of the i th focal plane is z. Based on the depth-fused 3-D perception described above, the luminance of the 3-D point is distributed between the (i-1)th and i th focal planes if z i-1zz i, otherwise between the i th and (i + 1)th focal planes if z izz i + 1. The luminance attribution to the i th focal plane is weighted by the depth z. It may be characterized by the ratio of the luminance attribution L i(z) on the ith focal plane at z i to that of the total scene luminance L(z), written as g i(z) = L i(z)/L(z), where L(z) = L i-1(z) + L i(z) if z i-1zz i or L(z) = L i(z) + L i + 1(z) if z izz i + 1. In general, the depth-weighted fusing function, w i(z), of the i th focal plane can be defined as:

wi(z)={gi(z),zizzi+1.(1i<n)1gi1(z),zi1zzi.(2in).
(3)

In summary, by knowing the rendered depth z of a 3-D virtual scene, the luminance levels of the multi-focal plane images can be modulated accordingly by the depth-weighted fusing functions in Eq. (3) to render pseudo-correct focus cues.

3. Models and methods for DFD quality assessment

In DFD displays, the adjacent focal planes are separated in space at a considerable distance. The retinal image quality apparently is expected to become worse when the eye is accommodated at a distance in between than when focusing on either the front or back focal planes. However, both the dioptric spacing between adjacent focal planes and the depth-weighted fusing functions can be selected such that the perceived depth of the fused pixel z^ closely matches with the rendered depth z and the image quality degradation is minimally perceptible as the observer accommodates to different distances between the focal planes.

The optical quality of a fused pixel in DFD displays may be quantitatively measured by the point spread function (PSF) of the retinal image, or equivalently by the modulation transfer function (MTF) which is characterized by the ratio of the contrast modulation of the retinal image to that of a sinusoidal object on the 3-D display. Without loss of generality, hereafter a dual-focal plane display is assumed and the results can be extended to n-focal planes. Based on Eq. (1), when the eye is accommodated at the rendered distance z, the PSF of the fused pixel, PSF 12, may be described as:
PSF12(z)=w1(z)PSF1(z,z1)+w2(z)PSF2(z,z2),
(4)
where PSF 1(z,z 1) and PSF 2(z,z 2) are the point spread functions of the front and back pixels, respectively, corresponding to the eye accommodated distance z. The MTF of a DFD display can then be calculated via the Fourier Transform (FT) of the PSF 12 and subsequently the FT of the PSF 1 and PSF 2.

Instead of using observer- and display-specific measurements to evaluate the PSF and MTF of DFD displays [2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

,3

3. S. J. Watt, K. Akeley, M. O. Ernst, and M. S. Banks, “Focus cues affect perceived depth,” J. Vis. 5(10), 834–862 (2005). [CrossRef]

,16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

], we adopt a schematic Arizona eye model to simulate and analyze the retinal image quality from simulated targets to derive generalizable results. In the fields of optical design and ophthalmology, various schematic eye models have been widely used to predict the performance of an optical system involved with human observers [19

19. J. E. Greivenkamp, J. Schwiegerling, J. M. Miller, and M. D. Mellinger, “Visual acuity modeling using optical raytracing of schematic eyes,” Am. J. Ophthalmol. 120(2), 227–240 (1995). [PubMed]

21

21. H. Hua, C. W. Pansing, and J. P. Rolland, “Modeling of an eye-imaging system for optimizing illumination schemes in an eye-tracked head-mounted display,” Appl. Opt. 46(31), 7757–7770 (2007). [CrossRef] [PubMed]

]. In this study, the Arizona eye model was set up in CODE V [22]. The Arizona eye model is designed to match clinical levels of aberration, both on- and off-axis fields, and can accommodate to different distances. Detailed parameters of the model can be found in [19

19. J. E. Greivenkamp, J. Schwiegerling, J. M. Miller, and M. D. Mellinger, “Visual acuity modeling using optical raytracing of schematic eyes,” Am. J. Ophthalmol. 120(2), 227–240 (1995). [PubMed]

,23

23. J. Schwiegerling, Field Guide to Visual and Ophthalmic Optics (SPIE Press, 2004).

]. The accommodative distance z, as shown in Fig. 1, determines the lens shape, conic constant and refractive index of the surfaces in the schematic eye. The distances of the front and back focal planes, z 1 and z 2 respectively, and their spacing z are varied to simulate different display configurations.

Based on the model setup described above, for a given eye accommodation status and display settings, PSF 1(z,z 1) and PSF 2(z,z 2) for an on-axis point source are simulated separately in CODE V. Using the relationship in Eq. (3), a series of PSF 12(z) are computed by varying w 1 from 1 to 0, which corresponds to varying the rendered depth z from z 1 to z 2. The corresponding MTF 12(z) of the DFD display is derived by taking the FT of PSF 12.

To evaluate the retinal image quality of a depth-fused pixel against a physical pixel placed at the same distance, we further simulate the PSF of a real point source placed at distance z, PSF ideal(z), and compute the corresponding MTF ideal(z). The degradation of MTF 12(z) from MTF ideal (z) is expected to vary with the dioptric spacing of the two adjacent focal planes, rendered depth z, as well as eye-specific parameters. Through comprehensive analysis of the retinal image quality of DFD displays, threshold values are established to ensure the degradation from a real display condition is minimally perceptible to average observers. Optimal depth-weighted fusing functions are then obtained.

4. Optimal DFD designs

As mentioned earlier, a fused pixel that is rendered to be at the dioptric midpoint of two adjacent focal planes is expected to have the worst retinal image quality compared with other points between the focal planes [2

2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

,16

16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

]. Therefore, in the analysis hereafter, we use the retinal image quality of a fused pixel rendered at the midpoint of two adjacent focal planes as a criterion to determine appropriate settings for display designs.

4.1 Optimal dioptric spacing

In this study, the overall focal range of a DFD display covers the depth varying from 3D (z 1) to 0D (z n). Within this range, we further assume a constant dioptric spacing between two adjacent focal planes (e.g. z i and z i + 1) independent of the dioptric midpoint of the focal plane pair relative to the eye noted as z i,i + 1 = (z i + z i + 1)/2 in Table 1. Using the simulation method described in Section 3, we validated this assumption by examining the dependence of the MTF of a fused pixel at the midpoint of two focal planes upon the dioptic distance of the midpoint to the eye whiling fixing other ocular and display factors (i.e. w 1 = w 2 = 0.5, Δz = 0.5D, z = z i,i + 1). As expected the MTF of a fused pixel at the midpoint varies as the midpoint gets closer to the eye due to the fact that the ocular aberrations are highly correlated to accommodation [27

27. D. A. Atchison, M. J. Collins, C. F. Wildsoet, J. Christensen, and M. D. Waterworth, “Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the Howland aberroscope technique,” Vision Res. 35(3), 313–323 (1995). [CrossRef] [PubMed]

,28

28. H. Cheng, J. K. Barnett, A. S. Vilupuru, J. D. Marsack, S. Kasthurirangan, R. A. Applegate, and A. Roorda, “A population study on changes in wave aberrations with accommodation,” J. Vis. 4(4), 272–280 (2004). [CrossRef] [PubMed]

]. However, the average variation is less than 15% for spatial frequencies below 20cpd for z i,i + 1 within the 0D~3D range.

Under these assumptions, it is feasible to study the effect of dioptric spacing on DFD displays by setting the midpoint of a pair of adjacent focal planes at an arbitrary position within the depth range without loss of generality. We thus chose 1D as the midpoint of a focal plane pair and varied their dioptric spacing Δz from 0.2D to 1D at an interval of 0.2D. For each dioptric spacing condition, the MTF of a fused pixel at the dioptric midpoint (i.e. MTF 12 (z = z i,i + 1)) of the two focal planes was calculated with the assumption that the luminance level is evenly divided between front and back focal planes. Figure 2 (a)
Fig. 2 (a) Modulation transfer functions of a depth-fused dual-focal plane display as a function of dioptric spacings of 0.2D (green circle markers), 0.4D (square), 0.6D (star), 0.8D (diamond), and 1.0D (triangle). (b) Modulation transfer functions as a function of accommodations with z = 1.3, 1.2, 1.1, 1.0, 0.9, 0.8, 0.7D. Medial focal plane is setup at 1D and the luminance ratio is L 1/L = 0.5. MTF of the ideal viewing condition is plotted as a light green dashed line, and defocused MTFs are plotted as red ( + 0.3D) and blue (−0.3D) dashed lines respectively in (a).
plots the results corresponding to different dioptric spacings. For comparison, on the same figure we also plotted MTF ideal, which corresponds to the MTF of a real pixel placed at the midpoint, and the MTF +0.3D and MTF -0.3D, which correspond to the MTF of the eye model with + 0.3D and −0.3D defocus from the midpoint focus, respectively. It is worth noting that ± 0.3D defocus was chosen to match the commonly accepted DOF of the human eye [25

25. D.A. Atchison, and G. Smith, Optics of the Human Eye (Oxford 2000).

,26

26. F. W. Campbell, “The depth of field of the human eye,” J. Mod. Opt. 4(4), 157–164 (1957).

,29

29. K. N. Ogle and J. T. Schwartz, “Depth of focus of the human eye,” J. Opt. Soc. Am. 49(3), 273–280 (1959). [CrossRef] [PubMed]

]. As expected, MTF 12 consistently degrades with the increase of the spacing of the focal planes. However, when Δz is no larger than 0.6D, MTF 12 falls within the region enclosed by MTF ideal (green dashed line) and the ± 0.3D defocused MTFs (the overlapped blue and red dashed lines). The results indicate that the DOF of the human eye under photopic viewing conditions can be selected as the threshold value of the dioptric spacing in multi-focal plane display designs, which ensures the degradation of the retinal image quality of a DFD display from an ideal display condition is minimally perceptible to average observers. If better retinal image quality is required for certain applications, a smaller Δz may be used but at the expenses of adding more focal planes. For instance, if Δz = 0.6D is selected, 6 focal planes would be sufficient to cover the depth range from 3.0D to 0D, while 9 focal planes would be necessary to cover the same range if Δz = 0.4D is selected. At the medium spatial frequency of 20cpd, the improvement of MTF 12 at the dioptric midpoint from 0.1 to 0.4 may be worth of the cost for demanding applications.

4.2 Optimal depth-weighted fusing function

By setting a dioptric spacing of Δz = 0.6D and a dioptric midpoint of z 12 = 1D from the eye, we further examined the MTF of a fused pixel while incrementally varying the eye accommodation distance from the front focal plane (z 1 = 1.3D) to the back focal plane (z 2 = 0.7D) at an increment of 0.1D, as shown in Fig. 2 (b). As expected, an accommodation distance at the dioptric midpoint (z = z 12 = 1D) would maximize the MTF of the fused pixel, while shifting the accommodation distance toward either front or back focal planes will always decrease the MTF. For instance, the MTF values for a target spatial frequency of 10cpd is reduced from 0.6 when z = 1D to nearly 0.when z = 1.3D or z = 0.7D. Many studies have investigated the effects of stimulus contrast and contrast gradient on eye accommodation in viewing real-world scenes [30

30. P. A. Ward, “The effect of stimulus contrast on the accommodation response,” Opththal. Physiol. Opt. 7(1), 9–15 (1987). [CrossRef]

]. Evidences from these studies suggested that the accommodative response attempts to maximize the contrast of the foveal retinal image and the contrast gradient helps stabilize the accommodation fluctuation of the eye on the target of interest. Therefore, we may conclude that pseudo-correct focus cues can be generated at the dioptric midpoint by applying an appropriate depth fusing filter even without the existence of a real focal plane.

To derive the dependence of the rendered accommodation cue on the depth-weighted fusing function as described in Eq. (2), we extended the MTF simulation shown in Fig. 2 (b) by incrementally varying w 1 from 1 to 0 at an increment of 0.01 while having w 2 = 1-w 1. For each w 1 increment, we simulated the MTF 12 of a fused pixel while incrementally varying the eye accommodation distance from the front focal plane (z 1 = 1.3D) to the back focal plane (z 2 = 0.7D) at an increment of 0.02D. We selected the accommodation distance that maximizes the MTF 12 to be the rendered accommodation cue corresponding to the given depth-weighted fusing factor (w 1) of the front focal plane. The accumulated results yield the optimal depth weighted luminance (L 1 and L 2) of the front and back focal planes to the luminance of the fused target (L) as a function of the accommodation distance (z) for a focal plane pair. We may further extend the method described above to more than two focal planes covering a much larger depth range. As an example, we chose a 6 focal plane DFD display design covering a depth range from 3D to 0D. By assuming a 0.6D dioptric spacing, 6 focal planes were placed at 3D (z 1), 2.4D (z 2), 1.8D (z 3), 1.2D (z 4), 0.6D (z 5), and 0D (z 6) respectively. In this display configuration, we repeated the above-described simulations independently to each adjacent pair of focal planes. The black solid curves in Fig. 4
Fig. 4 Simulated accommodation cue versus depth filter curves (black solid line), and the nonlinearly-fitted curves (red dashed line) in a 6-focal plane DFD display, with z 1 = 3D, z 6 = 0D, and Δz = 0.6D. Blue and green dashed lines indicate the box and linear depth filters respectively.
plotted the luminance ratio g i = L i/L (i = 1,2,3,4,5) of the front focal plane in each focal plane pair of (i, i + 1) as a function of the rendered accommodation cue z. On the same figure we also plotted a typical box filter (blue dashed curves), which corresponds to multi-focal plane displays without applying depth-weighted fusing method [9

9. J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]

], and a linear depth-weighted filter (green dashed curves) as proposed in [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

,11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

]. It is clear that the fusing functions based on the maximal MTF 12 values demonstrated noticeable nonlinearity. As mentioned in Section 3, since the retinal image quality is affected by defocus, we tentatively attribute the nonlinearity effect to the nonlinear degradation of the retinal image quality with defocus.

Based on the simulated results shown in Fig. 4, a periodical function g i(z) can be used to describe the dependence of the luminance ratio of the front focal plane in a given pair of focal planes upon the scene depth:
gi(z)=Li(z)/L=111+exp(zz'i,i+1Δz'),zizzi+1.(1i<6),
(5)
where zi,i + 1 represents the pseudo-correct accommodation cue rendered by a luminance ratio of g i(z = zi,i + 1) = 0.5 and Δz’ characterizes the nonlinearity of g i(z). Ideally, zi,i + 1 should be equal to the dioptric midpoint z i,i + 1. Table 2

Table 2. Parameters of Eq. (5) for a 6-Focal Plane DFD Display

table-icon
View This Table
| View All Tables
lists detailed parameters of g i(z) for the 6-focal plane DFD display. As the distance of the focal planes from the eye increases from 2.7D to 0.3D, we found the difference between z i,i + 1 and zi,i + 1 increased from −0.013D to + 0.024D. The slight mismatch between zi i,i + 1 and z i,i + 1 may be attributed to the dependence of spherical aberration on eye accommodation distances. The nonlinear fittings of the luminance ratio functions were plotted as red dashed curves in Fig. 4 with a correlation coefficient of 0.985 to the simulated black curves. The depth-weighted fusing function w i, as defined in Eq. (3), for each focal plane of an N-focal plane DFD display can then be obtained.

5. Retinal image qauality analysis

Figure 5
Fig. 5 (a) Depth map of a 3-D scene rendered by shaders, and retinal images of the same scene rendered by (b) box (c) linear and (d) nonlinear depth filters in a 6-focal plane DFD display.
demonstrated the simulated retinal images of a 3-D scene through a 6-focal plane DFD display with depth-weighted nonlinear fusing functions given in Eq. (5), as well as with the box and linear filters shown in Fig. 4. The six focal planes were placed at 3, 2.4, 1.8, 1.2, 0.6, 0D, and the accommodation of the observer’s eye was assumed at 0.5D. The 3-D scene consists of a planar object extending from 3D to 0.5D at a slanted angle relative to the z-axis (depth-axis) and a green grid as ground plane spanning the same depth range. The planar object is textured with a Sinusoidal grating subtending a spatial frequency of 1.5~9cpd from its left (front) to right (back) ends. The entire scene subtends a FOV of 14.2x10.7 degrees. The simulation of the DFD images takes five steps. We first render a regular 2-D perspective image of a 3-D scene using computer graphics rendering techniques. A 2-D depth map (Fig. 5a) in the same size as that of the 2-D perspective image is then generated by retrieving the depth (z) of each rendered pixel from the z-buffer in OpenGL shaders [18

18. G. Riguer, N. Tatarchuk, and J. Isidoro, ShaderX2: Shader Programming Tips and Tricks with DirectX 9, (Wordware, 2003).

]. Next, a set of six depth-weighted maps is generated, one for each of the focal planes by applying the depth-weighted filtering functions in Eq. (5) to the 2-D depth map. In the fourth step, we then render six focal plane images by individually applying each of the depth-weighted maps to the 2-D perspective image rendered in the first step through an alpha-blending technique. Finally, the 6-focal plane images are convolved with the corresponding PSFs of the eye determined by the specific accommodation distance (z = 0.5D) and the focal plane distances, and the resultant retinal image is then obtained by summing up the convolved images. Figures 5 (b), (c) and (d) show the simulated retinal images of the DFD display by employing a box [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

], linear [10

10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

,11

11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

], and nonlinear depth-weighted fusing function, respectively. As expected, the 3-D scene rendered by the box filter (Fig. 5b) indicates strong depth discontinuity effect around the midpoint of two adjacent focal planes, while those rendered by linear and nonlinear filters show smoothly rendered depths. In term of the contrast of these images, although we expect that the non-linear filters yielded higher image contrast in general than the linear filters, the contrast differences are barely visible by solely comparing Fig. 5 (c) and (d), partially due to the low spatial frequency of the grating target.

6. Conclusion

Acknowledgements

References and links

1.

J. P. Wann, S. Rushton, and M. Mon-Williams, “Natural problems for stereoscopic depth perception in virtual environments,” Vision Res. 35(19), 2731–2736 (1995). [CrossRef] [PubMed]

2.

D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]

3.

S. J. Watt, K. Akeley, M. O. Ernst, and M. S. Banks, “Focus cues affect perceived depth,” J. Vis. 5(10), 834–862 (2005). [CrossRef]

4.

M. Mon-Williams, J. P. Warm, and S. Rushton, “Binocular vision in a virtual world: visual deficits following the wearing of a head-mounted display,” Ophthalmic Physiol. Opt. 13(4), 387–391 (1993). [CrossRef] [PubMed]

5.

J. F. Heanue, M. C. Bashaw, and L. Hesselink, “Volume holographic storage and retrieval of digital data,” Science 265(5173), 749–752 (1994). [CrossRef] [PubMed]

6.

G. E. Favalora, J. Napoli, D. M. Hall, R. K. Dorval, M. G. Giovinco, M. J. Richmond, and W. S. Chun, “100 million-voxel volumetric display,” Proc. SPIE 4712, 300–312 (2002). [CrossRef]

7.

A. Sullivan, “A solid-state multi-planar volumetric display,” SID Symposium Digest of Technical Papers 34, 1531–1533 (2003).

8.

A. Jones, I. McDowall, H. Yamada, M. Bolas, and P. Debevec, “Rendering for an interactive 360° light field display,” ACM Trans. Graph. 26, 40–1–40–10 (2007).

9.

J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]

10.

K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]

11.

S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]

12.

C. Lee, S. Diverdi, and T. Höllerer, “Depth-fused 3D imagery on an immaterial display,” IEEE Trans. Vis. Comput. Graph. 15(1), 20–33 (2009). [CrossRef]

13.

S. Suyama, M. Date, and H. Takada, “Three-dimensional display system with dual frequency liquid crystal varifocal lens,” Jpn. J. Appl. Phys. 39(Part 1, No. 2A), 480–484 (2000). [CrossRef]

14.

B. T. Schowengerdt and E. J. Seibel, “True 3-D scanned voxel dis-plays using single or multiple light sources,” J. Soc. Inf. Disp. 14(2), 135–143 (2006). [CrossRef]

15.

S. Liu and H. Hua, “Time-multiplexed dual-focal plane head-mounted display with a liquid lens,” Opt. Lett. 34(11), 1642–1644 (2009). [CrossRef] [PubMed]

16.

G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716. [CrossRef] [PubMed]

17.

W. S. Stiles and B. H. Crawford, “The luminous efficiency of rays entering the eye pupil at different points,” Proc. R. Soc. Lond., B 112(778), 428–450 (1933). [CrossRef]

18.

G. Riguer, N. Tatarchuk, and J. Isidoro, ShaderX2: Shader Programming Tips and Tricks with DirectX 9, (Wordware, 2003).

19.

J. E. Greivenkamp, J. Schwiegerling, J. M. Miller, and M. D. Mellinger, “Visual acuity modeling using optical raytracing of schematic eyes,” Am. J. Ophthalmol. 120(2), 227–240 (1995). [PubMed]

20.

Y. L. Chen, B. Tan, and J. W. L. Lewis, “Simulation of eccentric photorefraction images,” Opt. Express 11(14), 1628–1642 (2003), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-11-14-1628. [CrossRef] [PubMed]

21.

H. Hua, C. W. Pansing, and J. P. Rolland, “Modeling of an eye-imaging system for optimizing illumination schemes in an eye-tracked head-mounted display,” Appl. Opt. 46(31), 7757–7770 (2007). [CrossRef] [PubMed]

22.

http://www.opticalres.com.

23.

J. Schwiegerling, Field Guide to Visual and Ophthalmic Optics (SPIE Press, 2004).

24.

R. A. Applegate and V. Lakshminarayanan, “Parametric representation of Stiles-Crawford functions: normal variation of peak location and directionality,” J. Opt. Soc. Am. A 10(7), 1611–1623 (1993). [CrossRef] [PubMed]

25.

D.A. Atchison, and G. Smith, Optics of the Human Eye (Oxford 2000).

26.

F. W. Campbell, “The depth of field of the human eye,” J. Mod. Opt. 4(4), 157–164 (1957).

27.

D. A. Atchison, M. J. Collins, C. F. Wildsoet, J. Christensen, and M. D. Waterworth, “Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the Howland aberroscope technique,” Vision Res. 35(3), 313–323 (1995). [CrossRef] [PubMed]

28.

H. Cheng, J. K. Barnett, A. S. Vilupuru, J. D. Marsack, S. Kasthurirangan, R. A. Applegate, and A. Roorda, “A population study on changes in wave aberrations with accommodation,” J. Vis. 4(4), 272–280 (2004). [CrossRef] [PubMed]

29.

K. N. Ogle and J. T. Schwartz, “Depth of focus of the human eye,” J. Opt. Soc. Am. 49(3), 273–280 (1959). [CrossRef] [PubMed]

30.

P. A. Ward, “The effect of stimulus contrast on the accommodation response,” Opththal. Physiol. Opt. 7(1), 9–15 (1987). [CrossRef]

31.

S. Liu, H. Hua, and D. W. Cheng, “A novel prototype for an optical see-through head-mounted display with addressable focus cues,” IEEE Trans. Vis. Comput. Graph. 16(3), 381–393 (2010). [CrossRef] [PubMed]

OCIS Codes
(120.2040) Instrumentation, measurement, and metrology : Displays
(120.2820) Instrumentation, measurement, and metrology : Heads-up displays
(330.7322) Vision, color, and visual optics : Visual optics, accommodation

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: March 2, 2010
Revised Manuscript: May 6, 2010
Manuscript Accepted: May 6, 2010
Published: May 17, 2010

Virtual Issues
Vol. 5, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Sheng Liu and Hong Hua, "A systematic method for designing depth-fused multi-focal plane three-dimensional displays," Opt. Express 18, 11562-11573 (2010)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-18-11-11562


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. P. Wann, S. Rushton, and M. Mon-Williams, “Natural problems for stereoscopic depth perception in virtual environments,” Vision Res. 35(19), 2731–2736 (1995). [CrossRef] [PubMed]
  2. D. M. Hoffman, A. R. Girshick, K. Akeley, and M. S. Banks, “Vergence-accommodation conflicts hinder visual performance and cause visual fatigue,” J. Vis. 8(3), 1–30 (2008). [CrossRef] [PubMed]
  3. S. J. Watt, K. Akeley, M. O. Ernst, and M. S. Banks, “Focus cues affect perceived depth,” J. Vis. 5(10), 834–862 (2005). [CrossRef]
  4. M. Mon-Williams, J. P. Warm, and S. Rushton, “Binocular vision in a virtual world: visual deficits following the wearing of a head-mounted display,” Ophthalmic Physiol. Opt. 13(4), 387–391 (1993). [CrossRef] [PubMed]
  5. J. F. Heanue, M. C. Bashaw, and L. Hesselink, “Volume holographic storage and retrieval of digital data,” Science 265(5173), 749–752 (1994). [CrossRef] [PubMed]
  6. G. E. Favalora, J. Napoli, D. M. Hall, R. K. Dorval, M. G. Giovinco, M. J. Richmond, and W. S. Chun, “100 million-voxel volumetric display,” Proc. SPIE 4712, 300–312 (2002). [CrossRef]
  7. A. Sullivan, “A solid-state multi-planar volumetric display,” SID Symposium Digest of Technical Papers 34, 1531–1533 (2003).
  8. A. Jones, I. McDowall, H. Yamada, M. Bolas, and P. Debevec, “Rendering for an interactive 360° light field display,” ACM Trans. Graph. 26, 40–1–40–10 (2007).
  9. J. P. Rolland, M. W. Krueger, and A. Goon, “Multifocal planes head-mounted displays,” Appl. Opt. 39(19), 3209–3215 (2000). [CrossRef]
  10. K. Akeley, S. J. Watt, A. R. Girshick, and M. S. Banks, “A stereo display prototype with multiple focal distances,” ACM Trans. Graph. 23(3), 804–813 (2004). [CrossRef]
  11. S. Suyama, S. Ohtsuka, H. Takada, K. Uehira, and S. Sakai, “Apparent 3-D image perceived from luminance-modulated two 2-D images displayed at different depths,” Vision Res. 44(8), 785–793 (2004). [CrossRef] [PubMed]
  12. C. Lee, S. Diverdi, and T. Höllerer, “Depth-fused 3D imagery on an immaterial display,” IEEE Trans. Vis. Comput. Graph. 15(1), 20–33 (2009). [CrossRef]
  13. S. Suyama, M. Date, and H. Takada, “Three-dimensional display system with dual frequency liquid crystal varifocal lens,” Jpn. J. Appl. Phys. 39(Part 1, No. 2A), 480–484 (2000). [CrossRef]
  14. B. T. Schowengerdt and E. J. Seibel, “True 3-D scanned voxel dis-plays using single or multiple light sources,” J. Soc. Inf. Disp. 14(2), 135–143 (2006). [CrossRef]
  15. S. Liu and H. Hua, “Time-multiplexed dual-focal plane head-mounted display with a liquid lens,” Opt. Lett. 34(11), 1642–1644 (2009). [CrossRef] [PubMed]
  16. G. D. Love, D. M. Hoffman, P. J. W. Hands, J. Gao, A. K. Kirby, and M. S. Banks, “High-speed switchable lens enables the development of a volumetric stereoscopic display,” Opt. Express 17(18), 15716–15725 (2009), http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-18-15716 . [CrossRef] [PubMed]
  17. W. S. Stiles and B. H. Crawford, “The luminous efficiency of rays entering the eye pupil at different points,” Proc. R. Soc. Lond., B 112(778), 428–450 (1933). [CrossRef]
  18. G. Riguer, N. Tatarchuk, and J. Isidoro, ShaderX2: Shader Programming Tips and Tricks with DirectX 9, (Wordware, 2003).
  19. J. E. Greivenkamp, J. Schwiegerling, J. M. Miller, and M. D. Mellinger, “Visual acuity modeling using optical raytracing of schematic eyes,” Am. J. Ophthalmol. 120(2), 227–240 (1995). [PubMed]
  20. Y. L. Chen, B. Tan, and J. W. L. Lewis, “Simulation of eccentric photorefraction images,” Opt. Express 11(14), 1628–1642 (2003), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-11-14-1628 . [CrossRef] [PubMed]
  21. H. Hua, C. W. Pansing, and J. P. Rolland, “Modeling of an eye-imaging system for optimizing illumination schemes in an eye-tracked head-mounted display,” Appl. Opt. 46(31), 7757–7770 (2007). [CrossRef] [PubMed]
  22. http://www.opticalres.com .
  23. J. Schwiegerling, Field Guide to Visual and Ophthalmic Optics (SPIE Press, 2004).
  24. R. A. Applegate and V. Lakshminarayanan, “Parametric representation of Stiles-Crawford functions: normal variation of peak location and directionality,” J. Opt. Soc. Am. A 10(7), 1611–1623 (1993). [CrossRef] [PubMed]
  25. D.A. Atchison, and G. Smith, Optics of the Human Eye (Oxford 2000).
  26. F. W. Campbell, “The depth of field of the human eye,” J. Mod. Opt. 4(4), 157–164 (1957).
  27. D. A. Atchison, M. J. Collins, C. F. Wildsoet, J. Christensen, and M. D. Waterworth, “Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the Howland aberroscope technique,” Vision Res. 35(3), 313–323 (1995). [CrossRef] [PubMed]
  28. H. Cheng, J. K. Barnett, A. S. Vilupuru, J. D. Marsack, S. Kasthurirangan, R. A. Applegate, and A. Roorda, “A population study on changes in wave aberrations with accommodation,” J. Vis. 4(4), 272–280 (2004). [CrossRef] [PubMed]
  29. K. N. Ogle and J. T. Schwartz, “Depth of focus of the human eye,” J. Opt. Soc. Am. 49(3), 273–280 (1959). [CrossRef] [PubMed]
  30. P. A. Ward, “The effect of stimulus contrast on the accommodation response,” Opththal. Physiol. Opt. 7(1), 9–15 (1987). [CrossRef]
  31. S. Liu, H. Hua, and D. W. Cheng, “A novel prototype for an optical see-through head-mounted display with addressable focus cues,” IEEE Trans. Vis. Comput. Graph. 16(3), 381–393 (2010). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited