Normal and diseased personal eye modeling using age-appropriate lens parameters

Ying-Ling Chen, L. Shi, J. W. L. Lewis, and M. Wang  »View Author Affiliations


Optics Express, Vol. 20, Issue 11, pp. 12498-12507 (2012)
http://dx.doi.org/10.1364/OE.20.012498


View Full Text Article

Acrobat PDF (3243 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Personalized eye modeling of normal and diseased eye conditions is attractive due to the recent availability of detailed ocular measurements in clinic environments and the promise of its medical and industrial applications. In the customized modeling, the optical properties of the crystalline lens including the gradient refractive index, the lens bio-geometry and orientation are typically assigned with average lens parameters from literature since typically they are not clinically available. Although, through the optical optimization by assigning lens parameters as variables, the clinical measured wavefront aberration can be achieved, the optimized lens biometry and orientation often end up at edges of the statistical distribution. Without an effective validation of these models today, the fidelity of the final lens (and therefore the model) remains questionable. To develop a more reliable customized model without detailed lens information, we incorporate age-appropriate lens parameters as the initial condition of optical optimization. A biconic lens optimization was first performed to provide a correct lens profile for accurate lower order aberration and then followed by the wavefront optimization. Clinical subjects were selected from all ages with both normal and diseased corneal and refractive conditions. 19 ammetropic eyes ( + 4D to −11D), and 16 keratoconus eyes (mild to moderate with cylinder 0.25 to 6D) were modeled. Age- and gender-corrected refractive index was evaluated. Final models attained the lens shapes comparable to the statistical distribution in their age.

© 2012 OSA

1. Introduction

Analytical eye models have been developed for over a century [1

1. A. Gullstrand, “The optical system of the eye,” in Physiological Optics 3rd ed., H. von Helmholtz (Hamburg, Voss, 1909), 1, 350–358.

5

5. R. Navarro, L. González, and J. L. Hernández-Matamoros, “On the prediction of optical aberrations by personalized eye models,” Optom. Vis. Sci. 83(6), 371–381 (2006). [CrossRef] [PubMed]

]. Traditional models use the average measured optical parameters and characteristics of healthy emmetropic adults. These models are valuable for the study of visual optics and for applications for common vision correction. However, these models are rotationally symmetric and cannot represent any individuals in the general population. Advances of ophthalmic technology in the last decade have made available detailed clinically measured ocular data for customized eye modeling [5

5. R. Navarro, L. González, and J. L. Hernández-Matamoros, “On the prediction of optical aberrations by personalized eye models,” Optom. Vis. Sci. 83(6), 371–381 (2006). [CrossRef] [PubMed]

7

7. Y.-L. Chen, B. Tan, K. Baker, J. W. L. Lewis, T. Swartz, Y. Jiang, and M. Wang, “Simulation of keratoconus observation in photorefraction,” Opt. Express 14(23), 11477–11485 (2006). [CrossRef] [PubMed]

]. Customized modeling for normal and diseased eyes offers current and potential assistance for ocular surgery [8

8. C. Winkler von Mohrenfels, A. Huber, B. Gabler, W. Herrmann, A. Kempe, C. Donitzky, and C. P. Lohmann, “Wavefront-guided laser epithelial keratomileusis with the wavelight concept system 500,” J. Refract. Surg. 20(5), S565–S569 (2004). [PubMed]

10

10. D. Y. Lin and E. E. Manche, “Custom-contoured ablation pattern method for the treatment of decentered laser ablations,” J. Cataract Refract. Surg. 30(8), 1675–1684 (2004). [CrossRef] [PubMed]

] and for the design of customer-tailored spectacle-, contact-, or intraocular lens [11

11. J. B. Almeida and A. M. Garcia, “Theoretical calculation of a contact lens thickness designed to correct the eye’s monochromatic aberrations,” Optom. Vis. Sci. 82(1), 59–63 (2005). [PubMed]

13

13. W. N. Charman, “Wavefront technology: past, present and future,” Cont. Lens Anterior Eye 28(2), 75–92 (2005). [CrossRef] [PubMed]

]. With additional modifications, these models can predict visual changes under varied environmental and physical conditions. Furthermore, ophthalmic measurement simulations using customized models of diseased eyes suggest a potentially versatile method for medical training as well as for the development of new instruments.

Today the most common and attainable clinical measurement data that are used for constructing customized schematic models are the 3-dimensional anterior segment structure data acquired from Pentacam or Orbscan instruments, the ocular wavefront aberration (WF) from any typical wavefront aberrometer, and the ocular element distances obtained from A-scan or IOL-Master. With these clinical data, a customized optical eye model can be constructed using contemporary optical software such as ZEMAX or Code V [5

5. R. Navarro, L. González, and J. L. Hernández-Matamoros, “On the prediction of optical aberrations by personalized eye models,” Optom. Vis. Sci. 83(6), 371–381 (2006). [CrossRef] [PubMed]

]. Optical optimization was performed to alter the unknown lens parameters to achieve the eye’s wavefront aberration. Questions regarding these models’ fidelity arise from the shortage of information of the crystalline lens of the individual eyes. Frankly, the variable lens parameters outnumber largely the required iteration variables for wavefront optimization.

In order to refine the initial lens condition for each individual, the literature of lens parameters and considered factors of age, gender, and refractive error was first reviewed and summarized. To test the lens-refining scheme we include 35 eyes over an age range of 40 + years that have normal lens but possess a large variation of normal and diseased corneal and ametropic conditions. We then constructed an initial model with clinical biometry data and age- and gender-corrected lens biometry. Optical computational optimizations on assigned lens parameters were performed in two stages to approach the individual's wavefont aberration. The equivalent refractive index was age- and gender-corrected using results from the Atchison and Dubbelman studies [14

14. D. A. Atchison, E. L. Markwell, S. Kasthurirangan, J. M. Pope, G. Smith, and P. G. Swann, “Age-related changes in optical and biometric characteristics of emmetropic eyes,” J. Vis. 8(4), 29 (2008). [CrossRef] [PubMed]

, 15

15. M. Dubbelman and G. L. Van der Heijde, “The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox,” Vision Res. 41(14), 1867–1877 (2001). [CrossRef] [PubMed]

], and the optimization results were compared to statistics. This study is essential to advance toward more reliable and realistic personalized eye modeling for future development and applications.

2. Personalized eye modeling

Subject

This study used 35 eyes examined in the Wang Vision Institute in Nashville. Nineteen of the 35 eyes are normal healthy eyes. They include two emmetropic, seven myopic, three hyperopic, and seven myopic astigmatic eyes. Spherical equivalent values range from −11.25 D to + 4.25 D, and the range of astigmatism are from 0 to 3D. Fifteen of these 19 eyes have best corrected visual acuity (BCVA) of 20/20, one is 20/25, and three are 20/30. The remainder (sixteen) of eyes exhibit mild to moderate keratoconus (KC and FFKC) with spherical equivalent values that range from −7.9 D to −0.1 D. Astigmatism ranges from 0.5 to 6 D. For the KC and FFKC eyes, there is no known abnormality other than that of the cornea. Four of these 16 eyes have BCVA of 20/20, two are 20/25, seven are 20/30, and three are 20/40. Four of these KC eyes have cylindrical refractive error less than 1 D. The patients’ ages range from 24 to 68 year old (41.5 +/− 12.6 years old).

Ophthalmic patient data

Anterior and posterior corneal topographies from Pentacam were utilized in the modeling. The spatial increments of these elevation maps were 0.1 mm in X- and Y- transverse dimensions, and 0.001 mm in Z-dimension. Cornea thickness (CT), anterior chamber depth (ACD), and the displacement (dx, dy) of the apex-to-center of the pupil were also acquired from Pentacam. Three measurements of wavefront aberration (WF) data were acquired from Wavescan. The modeling selected the WF data set with largest pupil size. If pupil sizes were the same in WF data, the one with smallest high-order aberration was chosen. IOL-Master and/or A-Scan were used to measure ocular axial length (AL). Lens thickness (LT) was obtained using A-Scan.

Crystalline lens parameters

To include in the lens model the dependence of the lens parameters on age, gender, and refractive error, we reviewed 36 lens biometry studies. The results of this review are shown in Figs. 1
Fig. 1 (a) Comparison of studies of age-correlation of lens thickness. The fitted curve (black) is: y(x) = 3.9-0.127x + 0.0116x2-(4.49E-4)x3 + (9.62E-6)x4-(1.15E-7)x5 + (7.14E-10)x6-(1.8E-12)x7; (b) Comparison of studies on age-dependence of equivalent refractive index.
-3
Fig. 3 Comparisons of studies of age-correlations asphericity of anterior (a) and posterior (b) lens surface. No significance of age-correlation was found in any of these studies. The conic constants on lens surfaces were free variables during the optical optimization of the customized models.
.

To our knowledge, no evidence has been found of correlation between sphero-cylindrical refractive error and any of lens properties in adults, children, and infant populations [16

16. D. A. Goss, H. G. Van Veen, B. B. Rainey, and B. Feng, “Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students,” Optom. Vis. Sci. 74(7), 489–495 (1997). [CrossRef] [PubMed]

26

26. S. Ziylan, D. Serin, and S. Karslioglu, “Myopia in preterm children at 12 to 24 months of age,” J. Pediatr. Ophthalmol. Strabismus 43(3), 152–156 (2006). [PubMed]

]. Thus, the patient’s refractive error condition would not influence lens parameters in the modeling. The age, however, is one significant factor for lens characteristics [27

27. Y.-L. Chen, B. Tan, L. Shi, J. Lewis, M. Wang, and K. Baker, “The shape of aging lens,” Invest. Ophthalmol. Vis. Sci. 51, E-Abstract 4593 (2010).

]. These age-dependent equations were plotted in dashed lines in Figs. 1, 2
Fig. 2 Comparisons of studies of age-correlations of anterior (a) and posterior (b) lens radii of curvature. The radii of curvature on lens surfaces were free variables during the optical optimization of the customized models. Anterior fitted line (black): y = 7.66 + 0.76x-(5.32E-2) x2 + (1.75E-3)x3-(3.08E-5)x4 + (2.77E-7)x5 + (9.96E-10)x6 ; Posterior fitted line: y = 5.09 + 0.234x-(9.37E-3) x2 + (1.63E-4)x3-(1.32E-6)x4 + (4.12E-9)x5.
, and 3. In Fig. 1, the plot on the left compares 18 studies of lens thickness. The age-trend was significant and showed rapid decrease of thickness from ~4mm at infancy to the minimum value ~3.4mm at 10 years old. After the age of 10, there was a slower rate of increase on lens thickness with age. The solid black line marks the fitted polynomial result [27

27. Y.-L. Chen, B. Tan, L. Shi, J. Lewis, M. Wang, and K. Baker, “The shape of aging lens,” Invest. Ophthalmol. Vis. Sci. 51, E-Abstract 4593 (2010).

]. Correlation of gender to lens thickness was investigated by Atchison in 2008 [14

14. D. A. Atchison, E. L. Markwell, S. Kasthurirangan, J. M. Pope, G. Smith, and P. G. Swann, “Age-related changes in optical and biometric characteristics of emmetropic eyes,” J. Vis. 8(4), 29 (2008). [CrossRef] [PubMed]

]. No significant correlation was found. Thus, we use the same age-dependent equation for both genders. Systematic inconsistency between measuring instruments was investigated by Atchison [14

14. D. A. Atchison, E. L. Markwell, S. Kasthurirangan, J. M. Pope, G. Smith, and P. G. Swann, “Age-related changes in optical and biometric characteristics of emmetropic eyes,” J. Vis. 8(4), 29 (2008). [CrossRef] [PubMed]

], Tong [28

28. L. Tong, S. M. Saw, D. Tan, K. S. Chia, W. Y. Chan, A. Carkeet, W. H. Chua, and C. Y. Hong, “Sensitivity and specificity of visual acuity screening for refractive errors in school children,” Optom. Vis. Sci. 79(10), 650–657 (2002). [CrossRef] [PubMed]

], and Koretz in [29

29. J. F. Koretz, P. L. Kaufman, M. W. Neider, and P. A. Goeckner, “Accommodation and presbyopia in the human eye--aging of the anterior segment,” Vision Res. 29(12), 1685–1692 (1989). [CrossRef] [PubMed]

] in 2008, 2002, and 1989, respectively, and a difference of lens thickness of up to 0.2 mm was estimated. This deviation range of +/− 0.2mm is illustrated by the grey band in the plot.

Many studies of lens radii of curvature are illustrated in Fig. 2, and the age-trend shows an extremum around the teenage period. Similarly, reference lines by polynomial fitting [27

27. Y.-L. Chen, B. Tan, L. Shi, J. Lewis, M. Wang, and K. Baker, “The shape of aging lens,” Invest. Ophthalmol. Vis. Sci. 51, E-Abstract 4593 (2010).

] and the estimated derivation ranges (grey bands) were plotted for comparison. In the Atchison 2008 study, no significant radii differences between genders were found. Therefore, we adopted gender-independent reference lines.

Conic constants of both the anterior and posterior lens surfaces have been reported in a few studies [15

15. M. Dubbelman and G. L. Van der Heijde, “The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox,” Vision Res. 41(14), 1867–1877 (2001). [CrossRef] [PubMed]

, 17

17. D. A. Atchison, “Optical models for human myopic eyes,” Vision Res. 46(14), 2236–2250 (2006). [CrossRef] [PubMed]

, 33

33. G. Smith, “The optical properties of the crystalline lens and their significance,” Clin. Exp. Optom. 86(1), 3–18 (2003). [CrossRef] [PubMed]

]. As shown in Fig. 3, the reported values of the conic constant range between 0 and −6 for anterior lens surface and between + 2 to −5 for posterior surface. Although plotted as functions of age in these studies, no significant correlation to age was found. In the personalized models of this current work, conic constants were therefore assigned to be free iteration variables during the biconic lens surface optimization.

Customized eye modeling

ZemaxTM optics code, (ZEMAX Development Corporation, Bellevue, WA, USA), was used in this modeling. For personalized modeling, two essential and distinct optical optimizations steps must be executed. The first is a biconic surface optimization that intended to approach the accurate lens profile and the eye’s low-order aberration. The second is to include microscopic perturbation on lens property to achieve the total ocular wavefront aberration. Without a carefully tailored lens profile optimization in the first step, the Zernike optimization that followed would most likely obtain the customer’s measured wavefront aberration regardless of the significance of the deviation of the lens profile from the real one, thereby giving a false sense of success.

Because of the demand of an absolutely minimal RMS wavefront error of the final eye model, the initial Pentacam topography data was extended from 1 to 0.01 micron meter precision. To retain the fidelity to the topographic profiles, we decompose the elevation raw data up to 25th order of Zernike terms and reconstruct the elevation maps from these coefficients. When rounded up 2 digits, the new topographies are equivalent to the original clinical data in every data point throughout the topographies. The two customized corneal surfaces were then imported without rotation to the Grid-Sag surfaces in the model. A spatial translation, (-dx, -dy), relative to the pupil center was assigned.

A Zernike phase plate was inserted in the ray-tracing sequence after the anterior cornea at the exit pupil plane (entrance pupil of the eye). The wavefront aberration map of the patient was imported to this surface, and the optical stop was assigned to it with the maximum size of the measured WF map. After the phase plate, an ideal thin lens with focal length of 100 m was inserted in front of the eye. The final image plane was placed at 100 m so that the optimization would ensure an eye model with the clinical measured wavefront aberration.

Since the gradient index of the natural human lens structure contributes to a degree of refraction and spherical aberration (SA), in the use of a constant refractive index lens, an equivalent index that is higher than the mean index and additional asphericity on the lens surfaces are expected to accommodate the loss of refraction and SA. We assigned five variables for optimization: the meridian angle, the two radii of curvature on the steepest and flattest meridians of the posterior lens surface, and the two conic constants on the two meridians of the same surface. The two radii and two conic constants on the anterior lens surface were assigned to “pick up” the values of the posterior surface with assigned constant ratios. The specific ratios for conic constants to pickup were 1. The ratio between anterior and posterior radii was age-dependent. It was assigned with the ratio of the two age-dependent reference lines in the two radii plots in Fig. 2.

We used real ray aiming, a selected wavelength at 0.785 um of the Wavescan and used default merit function with setting of RMS/spot radius/Centroid/Rectangular array 20X20. After the biconic 5-variable optimization, a Zernike sag optimization to 13th-order was performed on the posterior lens surface. After this optimization, the wavefront aberration of the eye model converged to the clinical measured data with an RMS error about 0.01 wave. Shown in Fig. 4
Fig. 4 RMS wavefront error of the eye models along the optical optimization steps.
is the RMS wavefront error along the optimization steps. The biconic len profile optimization step significantly reduced the residual between total wavefront and corneal wavefront. The magnitude of final RMS error depends dominantly on the pupil size.

3. Results and discussion

The results of biconic surface optimization were presented in Figs. 4, 5
Fig. 5 Optimization results of the radius of curvature of anterior lens surface (left) and posterior surface (right). The lens refractive index of Dulbbelman 2001 [15] study was used in this modeling.
, and 6
Fig. 6 Optimization results of the radius of curvature of anterior lens surface (left) and posterior surface (right). The lens refractive index of Atchison 2008 study [14] was used in this modeling.
. The radii (of curvature) of anterior lens and the posterior surfaces were plotted on the left and the right of each figure respectively. On the background of each plot, a reference black line and the grey band describe the average age trend of deviation from multiple studies that was described earlier. Symbols described the results of the 35 customized models. Blue circles represented the 19 normal eyes, and red triangles were the 16 keratoconus eyes. Both steepest and flattest radii of curvatures of the lens surface were plotted. Linear fittings were given in dashed lines for both normal (blue dash) and the keratoconus (red dash) groups.

In Fig. 5, Dulbbelman’s age-dependent equivalent refractive index (see the blue dashed line in right plot of Fig. 1) was used in the modeling. The optimization result of lens radii tended to be smaller than the values that were reported from majority of literature including Dulbbelman’s (see reference line and also compare to Fig. 2). The lens surfaces were steeper, and the deviation from the average line was worse when age increased toward 70 years. The conic constants after optimization were found in −3.35+/−2.21, a reasonable range compared to publications.

For comparison and further investigation, we performed the three computations: a) use gender- but no age-correction, b) use age- but no gender- correction, and c) use neither age-nor gender-correction but use a constant refractive index that is appropriate for an age of 35 years from Atchison’s 2008 equation. We found that the consideration of age and/or gender correlations in refractive index resulted did not provide significantly better fit to the radii statistics. Figure 7
Fig. 7 Optimization results of the radius of curvature of anterior lens surface (left) and posterior surface (right). The 35 years old lens refractive index of Atchison 2008 study [14], n = 43835, was used in this modeling.
shows results obtained using the constant refractive index for an age of 35 years. Conic constants results were in −4.01 +/− 3.06.

4. Summary

Acknowledgments

The authors would like to acknowledge the research support of the Center for Laser Applications of the University of Tennessee Space Institute and the support for eye modeling and keratoconus research of the National Eye Institute grants R21 EY18385 and R21 EY018935 respectively. We appreciate the insightful comments and questions of our reviewers that resulted in improvements of our presentation.

References and links

1.

A. Gullstrand, “The optical system of the eye,” in Physiological Optics 3rd ed., H. von Helmholtz (Hamburg, Voss, 1909), 1, 350–358.

2.

W. Lotmar, “Theoretical eye model with aspherics,” J. Opt. Soc. Am. 61(11), 1522–1529 (1971). [CrossRef]

3.

R. Navarro, J. Santamaría, and J. Bescós, “Accommodation-dependent model of the human eye with aspherics,” J. Opt. Soc. Am. A 2(8), 1273–1281 (1985). [CrossRef] [PubMed]

4.

H. L. Liou and N. A. Brennan, “Anatomically accurate, finite model eye for optical modeling,” J. Opt. Soc. Am. A 14(8), 1684–1695 (1997). [CrossRef] [PubMed]

5.

R. Navarro, L. González, and J. L. Hernández-Matamoros, “On the prediction of optical aberrations by personalized eye models,” Optom. Vis. Sci. 83(6), 371–381 (2006). [CrossRef] [PubMed]

6.

P. Rosales and S. Marcos, “Customized computer models of eyes with intraocular lenses,” Opt. Express 15(5), 2204–2218 (2007). [CrossRef] [PubMed]

7.

Y.-L. Chen, B. Tan, K. Baker, J. W. L. Lewis, T. Swartz, Y. Jiang, and M. Wang, “Simulation of keratoconus observation in photorefraction,” Opt. Express 14(23), 11477–11485 (2006). [CrossRef] [PubMed]

8.

C. Winkler von Mohrenfels, A. Huber, B. Gabler, W. Herrmann, A. Kempe, C. Donitzky, and C. P. Lohmann, “Wavefront-guided laser epithelial keratomileusis with the wavelight concept system 500,” J. Refract. Surg. 20(5), S565–S569 (2004). [PubMed]

9.

J. Castanera, A. Serra, and C. Rios, “Wavefront-guided ablation with Bausch and Lomb Zyoptix for retreatments after laser in situ keratomileusis for myopia,” J. Refract. Surg. 20(5), 439–443 (2004). [PubMed]

10.

D. Y. Lin and E. E. Manche, “Custom-contoured ablation pattern method for the treatment of decentered laser ablations,” J. Cataract Refract. Surg. 30(8), 1675–1684 (2004). [CrossRef] [PubMed]

11.

J. B. Almeida and A. M. Garcia, “Theoretical calculation of a contact lens thickness designed to correct the eye’s monochromatic aberrations,” Optom. Vis. Sci. 82(1), 59–63 (2005). [PubMed]

12.

J. Marsack, T. Milner, G. Rylander, N. Leach, and A. Roorda, “Applying wavefront sensors and corneal topography to keratoconus,” Biomed. Sci. Instrum. 38, 471–476 (2002). [PubMed]

13.

W. N. Charman, “Wavefront technology: past, present and future,” Cont. Lens Anterior Eye 28(2), 75–92 (2005). [CrossRef] [PubMed]

14.

D. A. Atchison, E. L. Markwell, S. Kasthurirangan, J. M. Pope, G. Smith, and P. G. Swann, “Age-related changes in optical and biometric characteristics of emmetropic eyes,” J. Vis. 8(4), 29 (2008). [CrossRef] [PubMed]

15.

M. Dubbelman and G. L. Van der Heijde, “The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox,” Vision Res. 41(14), 1867–1877 (2001). [CrossRef] [PubMed]

16.

D. A. Goss, H. G. Van Veen, B. B. Rainey, and B. Feng, “Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students,” Optom. Vis. Sci. 74(7), 489–495 (1997). [CrossRef] [PubMed]

17.

D. A. Atchison, “Optical models for human myopic eyes,” Vision Res. 46(14), 2236–2250 (2006). [CrossRef] [PubMed]

18.

S. Stenstrom, “Investigation of the variation and the correlation of the optical elements of human eye Part V—Chapter III (D. Woolf, Trans.),” Am. J. Optom. Arch. Am. Acad. Optom. 25, 438–449 (1948). [PubMed]

19.

N. A. McBrien and D. W. Adams, “A longitudinal investigation of adult-onset and adult-progression of myopia in an occupational group. Refractive and biometric findings,” Invest. Ophthalmol. Vis. Sci. 38(2), 321–333 (1997). [PubMed]

20.

R. Scott and T. Grosvenor, “Structural model for emmetropic and myopic eyes,” Ophthalmic Physiol. Opt. 13(1), 41–47 (1993). [CrossRef] [PubMed]

21.

H. M. Cheng, O. S. Singh, K. K. Kwong, J. Xiong, B. T. Woods, and T. J. Brady, “Shape of the myopic eye as seen with high-resolution magnetic resonance imaging,” Optom. Vis. Sci. 69(9), 698–701 (1992). [CrossRef] [PubMed]

22.

L. A. Jones, G. L. Mitchell, D. O. Mutti, J. R. Hayes, M. L. Moeschberger, and K. Zadnik, “Comparison of ocular component growth curves among refractive error groups in children,” Invest. Ophthalmol. Vis. Sci. 46(7), 2317–2327 (2005). [CrossRef] [PubMed]

23.

A. Cook, S. White, M. Batterbury, and D. Clark, “Ocular growth and refractive error development in premature infants without retinopathy of prematurity,” Invest. Ophthalmol. Vis. Sci. 44(3), 953–960 (2003). [CrossRef] [PubMed]

24.

D. O. Mutti, G. L. Mitchell, L. A. Jones, N. E. Friedman, S. L. Frane, W. K. Lin, M. L. Moeschberger, and K. Zadnik, “Axial growth and changes in lenticular and corneal power during emmetropization in infants,” Invest. Ophthalmol. Vis. Sci. 46(9), 3074–3080 (2005). [CrossRef] [PubMed]

25.

F. C. Pennie, I. C. Wood, C. Olsen, S. White, and W. N. Charman, “A longitudinal study of the biometric and refractive changes in full-term infants during the first year of life,” Vision Res. 41(21), 2799–2810 (2001). [CrossRef] [PubMed]

26.

S. Ziylan, D. Serin, and S. Karslioglu, “Myopia in preterm children at 12 to 24 months of age,” J. Pediatr. Ophthalmol. Strabismus 43(3), 152–156 (2006). [PubMed]

27.

Y.-L. Chen, B. Tan, L. Shi, J. Lewis, M. Wang, and K. Baker, “The shape of aging lens,” Invest. Ophthalmol. Vis. Sci. 51, E-Abstract 4593 (2010).

28.

L. Tong, S. M. Saw, D. Tan, K. S. Chia, W. Y. Chan, A. Carkeet, W. H. Chua, and C. Y. Hong, “Sensitivity and specificity of visual acuity screening for refractive errors in school children,” Optom. Vis. Sci. 79(10), 650–657 (2002). [CrossRef] [PubMed]

29.

J. F. Koretz, P. L. Kaufman, M. W. Neider, and P. A. Goeckner, “Accommodation and presbyopia in the human eye--aging of the anterior segment,” Vision Res. 29(12), 1685–1692 (1989). [CrossRef] [PubMed]

30.

A. V. Goncharov and C. Dainty, “Wide-field schematic eye models with gradient-index lens,” J. Opt. Soc. Am. A 24(8), 2157–2174 (2007). [CrossRef] [PubMed]

31.

A. V. Goncharov, M. Nowakowski, M. T. Sheehan, and C. Dainty, “Reconstruction of the optical system of the human eye with reverse ray-tracing,” Opt. Express 16(3), 1692–1703 (2008). [CrossRef] [PubMed]

32.

C. E. Campbell, “Nested shell optical model of the lens of the human eye,” J. Opt. Soc. Am. A 27(11), 2432–2441 (2010). [CrossRef] [PubMed]

33.

G. Smith, “The optical properties of the crystalline lens and their significance,” Clin. Exp. Optom. 86(1), 3–18 (2003). [CrossRef] [PubMed]

34.

J. Rozema, D. Atchison, and M. Tassignon, “Statistical eye model for normal eyes,” Invest. Ophthalmol. Vis. Sci. 52, 4525–4533 (2011). [CrossRef] [PubMed]

OCIS Codes
(170.4460) Medical optics and biotechnology : Ophthalmic optics and devices
(170.4580) Medical optics and biotechnology : Optical diagnostics for medicine
(330.0330) Vision, color, and visual optics : Vision, color, and visual optics
(330.4060) Vision, color, and visual optics : Vision modeling
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices

ToC Category:
Vision, Color, and Visual Optics

History
Original Manuscript: March 6, 2012
Revised Manuscript: May 3, 2012
Manuscript Accepted: May 15, 2012
Published: May 17, 2012

Virtual Issues
Vol. 7, Iss. 7 Virtual Journal for Biomedical Optics

Citation
Ying-Ling Chen, L. Shi, J. W. L. Lewis, and M. Wang, "Normal and diseased personal eye modeling using age-appropriate lens parameters," Opt. Express 20, 12498-12507 (2012)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-20-11-12498


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. Gullstrand, “The optical system of the eye,” in Physiological Optics 3rd ed., H. von Helmholtz (Hamburg, Voss, 1909), 1, 350–358.
  2. W. Lotmar, “Theoretical eye model with aspherics,” J. Opt. Soc. Am.61(11), 1522–1529 (1971). [CrossRef]
  3. R. Navarro, J. Santamaría, and J. Bescós, “Accommodation-dependent model of the human eye with aspherics,” J. Opt. Soc. Am. A2(8), 1273–1281 (1985). [CrossRef] [PubMed]
  4. H. L. Liou and N. A. Brennan, “Anatomically accurate, finite model eye for optical modeling,” J. Opt. Soc. Am. A14(8), 1684–1695 (1997). [CrossRef] [PubMed]
  5. R. Navarro, L. González, and J. L. Hernández-Matamoros, “On the prediction of optical aberrations by personalized eye models,” Optom. Vis. Sci.83(6), 371–381 (2006). [CrossRef] [PubMed]
  6. P. Rosales and S. Marcos, “Customized computer models of eyes with intraocular lenses,” Opt. Express15(5), 2204–2218 (2007). [CrossRef] [PubMed]
  7. Y.-L. Chen, B. Tan, K. Baker, J. W. L. Lewis, T. Swartz, Y. Jiang, and M. Wang, “Simulation of keratoconus observation in photorefraction,” Opt. Express14(23), 11477–11485 (2006). [CrossRef] [PubMed]
  8. C. Winkler von Mohrenfels, A. Huber, B. Gabler, W. Herrmann, A. Kempe, C. Donitzky, and C. P. Lohmann, “Wavefront-guided laser epithelial keratomileusis with the wavelight concept system 500,” J. Refract. Surg.20(5), S565–S569 (2004). [PubMed]
  9. J. Castanera, A. Serra, and C. Rios, “Wavefront-guided ablation with Bausch and Lomb Zyoptix for retreatments after laser in situ keratomileusis for myopia,” J. Refract. Surg.20(5), 439–443 (2004). [PubMed]
  10. D. Y. Lin and E. E. Manche, “Custom-contoured ablation pattern method for the treatment of decentered laser ablations,” J. Cataract Refract. Surg.30(8), 1675–1684 (2004). [CrossRef] [PubMed]
  11. J. B. Almeida and A. M. Garcia, “Theoretical calculation of a contact lens thickness designed to correct the eye’s monochromatic aberrations,” Optom. Vis. Sci.82(1), 59–63 (2005). [PubMed]
  12. J. Marsack, T. Milner, G. Rylander, N. Leach, and A. Roorda, “Applying wavefront sensors and corneal topography to keratoconus,” Biomed. Sci. Instrum.38, 471–476 (2002). [PubMed]
  13. W. N. Charman, “Wavefront technology: past, present and future,” Cont. Lens Anterior Eye28(2), 75–92 (2005). [CrossRef] [PubMed]
  14. D. A. Atchison, E. L. Markwell, S. Kasthurirangan, J. M. Pope, G. Smith, and P. G. Swann, “Age-related changes in optical and biometric characteristics of emmetropic eyes,” J. Vis.8(4), 29 (2008). [CrossRef] [PubMed]
  15. M. Dubbelman and G. L. Van der Heijde, “The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox,” Vision Res.41(14), 1867–1877 (2001). [CrossRef] [PubMed]
  16. D. A. Goss, H. G. Van Veen, B. B. Rainey, and B. Feng, “Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students,” Optom. Vis. Sci.74(7), 489–495 (1997). [CrossRef] [PubMed]
  17. D. A. Atchison, “Optical models for human myopic eyes,” Vision Res.46(14), 2236–2250 (2006). [CrossRef] [PubMed]
  18. S. Stenstrom, “Investigation of the variation and the correlation of the optical elements of human eye Part V—Chapter III (D. Woolf, Trans.),” Am. J. Optom. Arch. Am. Acad. Optom.25, 438–449 (1948). [PubMed]
  19. N. A. McBrien and D. W. Adams, “A longitudinal investigation of adult-onset and adult-progression of myopia in an occupational group. Refractive and biometric findings,” Invest. Ophthalmol. Vis. Sci.38(2), 321–333 (1997). [PubMed]
  20. R. Scott and T. Grosvenor, “Structural model for emmetropic and myopic eyes,” Ophthalmic Physiol. Opt.13(1), 41–47 (1993). [CrossRef] [PubMed]
  21. H. M. Cheng, O. S. Singh, K. K. Kwong, J. Xiong, B. T. Woods, and T. J. Brady, “Shape of the myopic eye as seen with high-resolution magnetic resonance imaging,” Optom. Vis. Sci.69(9), 698–701 (1992). [CrossRef] [PubMed]
  22. L. A. Jones, G. L. Mitchell, D. O. Mutti, J. R. Hayes, M. L. Moeschberger, and K. Zadnik, “Comparison of ocular component growth curves among refractive error groups in children,” Invest. Ophthalmol. Vis. Sci.46(7), 2317–2327 (2005). [CrossRef] [PubMed]
  23. A. Cook, S. White, M. Batterbury, and D. Clark, “Ocular growth and refractive error development in premature infants without retinopathy of prematurity,” Invest. Ophthalmol. Vis. Sci.44(3), 953–960 (2003). [CrossRef] [PubMed]
  24. D. O. Mutti, G. L. Mitchell, L. A. Jones, N. E. Friedman, S. L. Frane, W. K. Lin, M. L. Moeschberger, and K. Zadnik, “Axial growth and changes in lenticular and corneal power during emmetropization in infants,” Invest. Ophthalmol. Vis. Sci.46(9), 3074–3080 (2005). [CrossRef] [PubMed]
  25. F. C. Pennie, I. C. Wood, C. Olsen, S. White, and W. N. Charman, “A longitudinal study of the biometric and refractive changes in full-term infants during the first year of life,” Vision Res.41(21), 2799–2810 (2001). [CrossRef] [PubMed]
  26. S. Ziylan, D. Serin, and S. Karslioglu, “Myopia in preterm children at 12 to 24 months of age,” J. Pediatr. Ophthalmol. Strabismus43(3), 152–156 (2006). [PubMed]
  27. Y.-L. Chen, B. Tan, L. Shi, J. Lewis, M. Wang, and K. Baker, “The shape of aging lens,” Invest. Ophthalmol. Vis. Sci.51, E-Abstract 4593 (2010).
  28. L. Tong, S. M. Saw, D. Tan, K. S. Chia, W. Y. Chan, A. Carkeet, W. H. Chua, and C. Y. Hong, “Sensitivity and specificity of visual acuity screening for refractive errors in school children,” Optom. Vis. Sci.79(10), 650–657 (2002). [CrossRef] [PubMed]
  29. J. F. Koretz, P. L. Kaufman, M. W. Neider, and P. A. Goeckner, “Accommodation and presbyopia in the human eye--aging of the anterior segment,” Vision Res.29(12), 1685–1692 (1989). [CrossRef] [PubMed]
  30. A. V. Goncharov and C. Dainty, “Wide-field schematic eye models with gradient-index lens,” J. Opt. Soc. Am. A24(8), 2157–2174 (2007). [CrossRef] [PubMed]
  31. A. V. Goncharov, M. Nowakowski, M. T. Sheehan, and C. Dainty, “Reconstruction of the optical system of the human eye with reverse ray-tracing,” Opt. Express16(3), 1692–1703 (2008). [CrossRef] [PubMed]
  32. C. E. Campbell, “Nested shell optical model of the lens of the human eye,” J. Opt. Soc. Am. A27(11), 2432–2441 (2010). [CrossRef] [PubMed]
  33. G. Smith, “The optical properties of the crystalline lens and their significance,” Clin. Exp. Optom.86(1), 3–18 (2003). [CrossRef] [PubMed]
  34. J. Rozema, D. Atchison, and M. Tassignon, “Statistical eye model for normal eyes,” Invest. Ophthalmol. Vis. Sci.52, 4525–4533 (2011). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited