Broadly tunable femtosecond near- and mid-IR source by direct pumping of an OPA with a 41.7 MHz Yb:KGW oscillator

Joachim Krauth, Andy Steinmann, Robin Hegenbarth, Matteo Conforti, and Harald Giessen  »View Author Affiliations


Optics Express, Vol. 21, Issue 9, pp. 11516-11522 (2013)
http://dx.doi.org/10.1364/OE.21.011516


View Full Text Article

Acrobat PDF (3600 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We generate over half a watt of tunable near-IR (1380-1830 nm) and several hundred milliwatts in the mid-IR (2.4-4.2 µm) as well as milliwatt level mid-IR (4.85-9.33 µm) femtosecond radiation by pumping an optical parametric amplifier directly with a 7.4 W Yb:KGW oscillator at 41.7 MHz repetition rate. We use 5 mm PPLN and 2 mm GaSe as downconversion crystals and seed this process by a supercontinuum from a tapered fiber. The system is extremely simple and very stable and could replace more complex OPOs as tunable light sources.

© 2013 OSA

1. Introduction

Laser sources delivering broadly tunable femtosecond pulses at high repetition rates enable a number of key applications in time-resolved spectroscopy. Optical parametric amplifiers (OPAs) [1

1. G. Cerullo and S. De Silvestri, “Ultrafast optical parametric amplifiers,” Rev. Sci. Instrum. 74(1), 1–18 (2003). [CrossRef]

] seeded with a white-light continuum are powerful tools for such applications. Due to their simple setup and spectral versatility, they have many advantages over optical parametric oscillators (OPOs) [2

2. T. Südmeyer, J. Aus der Au, R. Paschotta, U. Keller, P. G. R. Smith, G. W. Ross, and D. C. Hanna, “Femtosecond fiber-feedback optical parametric oscillator,” Opt. Lett. 26(5), 304–306 (2001). [CrossRef] [PubMed]

4

4. R. Hegenbarth, A. Steinmann, G. Tóth, J. Hebling, and H. Giessen, “Two-color femtosecond optical parametric oscillator with 1.7 W output pumped by a 7.4 W Yb:KGW laser,” J. Opt. Soc. Am. B 28(5), 1344–1352 (2011). [CrossRef]

]. However, they require rather high pump energies, typically provided by amplified laser systems, limiting the repetition rate to a few hundred kilohertz [5

5. D. Brida, M. Marangoni, C. Manzoni, S. D. Silvestri, and G. Cerullo, “Two-optical-cycle pulses in the mid-infrared from an optical parametric amplifier,” Opt. Lett. 33(24), 2901–2903 (2008). [CrossRef] [PubMed]

7

7. F. Silva, P. K. Bates, A. Esteban-Martin, M. Ebrahim-Zadeh, and J. Biegert, “High-average-power, carrier-envelope phase-stable, few-cycle pulses at 2.1 μm from a collinear BiB3O6 optical parametric amplifier,” Opt. Lett. 37(5), 933–935 (2012). [CrossRef] [PubMed]

]. Recently, the repetition rate of OPAs has been pushed to the MHz range by using laser oscillators with cavity dumping [8

8. A. Killi, A. Steinmann, G. Palmer, U. Morgner, H. Bartelt, and J. Kobelke, “Megahertz optical parametric amplifier pumped by a femtosecond oscillator,” Opt. Lett. 31(1), 125–127 (2006). [CrossRef] [PubMed]

10

10. M. Marangoni, R. Osellame, R. Ramponi, G. Cerullo, A. Steinmann, and U. Morgner, “Near-infrared optical parametric amplifier at 1 MHz directly pumped by a femtosecond oscillator,” Opt. Lett. 32(11), 1489–1491 (2007). [CrossRef] [PubMed]

] or fiber amplifiers [11

11. T. V. Andersen, O. Schmidt, C. Bruchmann, J. Limpert, C. Aguergaray, E. Cormier, and A. Tünnermann, “High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier,” Opt. Express 14(11), 4765–4773 (2006). [CrossRef] [PubMed]

,12

12. C. Schriever, S. Lochbrunner, P. Krok, and E. Riedle, “Tunable pulses from below 300 to 970 nm with durations down to 14 fs based on a 2 MHz ytterbium-doped fiber system,” Opt. Lett. 33(2), 192–194 (2008). [CrossRef] [PubMed]

]. Later on, an OPA with 50 MHz repetition rate pumped by a frequency-doubled Yb:fiber amplifier and seeded by a supercontinuum has been demonstrated [13

13. Y.-W. Tzeng, Y.-Y. Lin, C.-H. Huang, J.-M. Liu, H.-C. Chui, H.-L. Liu, J. M. Stone, J. C. Knight, and S.-W. Chu, “Broadband tunable optical parametric amplification from a single 50 MHz ultrafast fiber laser,” Opt. Express 17(9), 7304–7309 (2009). [CrossRef] [PubMed]

].

Especially the mid-IR spectral region has attracted great interest recently [14

14. A. Schliesser, N. Picqué, and T. W. Hänsch, “Mid-infrared frequency combs,” Nat. Photonics 6(7), 440–449 (2012). [CrossRef]

], because many molecules exhibit vibration bands in this spectral region. For example, broadband mid-IR sources can be combined with scattering-type scanning near-field optical microscopes, which give access to both spatial and spectral information on the nanoscale [15

15. F. Huth, M. Schnell, J. Wittborn, N. Ocelic, and R. Hillenbrand, “Infrared-spectroscopic nanoimaging with a thermal source,” Nat. Mater. 10(5), 352–356 (2011). [CrossRef] [PubMed]

]. Among various methods of generating mid-IR radiation [16

16. S. Marzenell, R. Beigang, and R. Wallenstein, “Synchronously pumped femtosecond optical parametric oscillator based on AgGaSe2 tunable from 2 µm to 8 µm,” Appl. Phys. B 69(5-6), 423–428 (1999). [CrossRef]

,17

17. R. Hegenbarth, A. Steinmann, S. Sarkisov, and H. Giessen, “Milliwatt-level mid-infrared (10.5-16.5 μm) difference frequency generation with a femtosecond dual-signal-wavelength optical parametric oscillator,” Opt. Lett. 37(17), 3513–3515 (2012). [CrossRef] [PubMed]

], difference frequency generation schemes are promising due to their simple setup [18

18. C. Erny, K. Moutzouris, J. Biegert, D. Kühlke, F. Adler, A. Leitenstorfer, and U. Keller, “Mid-infrared difference-frequency generation of ultrashort pulses tunable between 3.2 and 4.8 microm from a compact fiber source,” Opt. Lett. 32(9), 1138–1140 (2007). [CrossRef] [PubMed]

21

21. C. R. Phillips, J. Jiang, C. Mohr, A. C. Lin, C. Langrock, M. Snure, D. Bliss, M. Zhu, I. Hartl, J. S. Harris, M. E. Fermann, and M. M. Fejer, “Widely tunable midinfrared difference frequency generation in orientation-patterned GaAs pumped with a femtosecond Tm-fiber system,” Opt. Lett. 37(14), 2928–2930 (2012). [CrossRef] [PubMed]

].

2. Experimental setup

Here, we present an OPA that is directly pumped by a simple diode-pumped solid-state oscillator without the need for any amplifier or cavity dumping. We generate over half a watt of signal power in the near-IR (1380-1830 nm), several hundred milliwatts of mid-IR from 2.4 to 4.2 µm, and milliwatt level mid-IR radiation from 4.85 to 9.33 µm.

The experimental setup is shown in Fig. 1
Fig. 1 Experimental setup of the OPA. For near-IR amplification we use a PPLN crystal and for mid-IR generation a GaSe crystal.
. We employ a passively mode-locked dual-crystal Yb:KGW oscillator [22

22. A. Steinmann, B. Metzger, R. Hegenbarth, and H. Giessen, “Compact 7.4 W femtosecond oscillator for white-light generation and nonlinear microscopy,” Conference on Lasers and Electro-Optics, OSA Technical Digest (CD) (Optical Society of America, 2011), paper CThAA5.

] delivering up to 7.4 W average power with 425 fs pulse duration and 41.7 MHz repetition rate at 1040 nm as pump source. Approximately 600 mW of the laser power is used to generate a supercontinuum seed in an 8 cm long tapered fiber with 4 µm waist diameter [23

23. B. Metzger, A. Steinmann, F. Hoos, S. Pricking, and H. Giessen, “Compact laser source for high-power white-light and widely tunable sub 65 fs laser pulses,” Opt. Lett. 35(23), 3961–3963 (2010). [CrossRef] [PubMed]

], whereas the remaining light is used to pump the parametric amplifier. The tapered fiber exhibits a typical throughput of 50%. The signal beam and the pump beam are combined with a dichroic mirror in a collinear interaction geometry and focused separately into a 5 mm long periodically poled lithium niobate (PPLN) crystal. For focusing we employ lenses with 100 mm focal length for both beams, leading to mode radii of 15 µm (vertical) and 20 µm (horizontal).

3. Experimental results

In Fig. 2
Fig. 2 OPA signal power and conversion efficiency (ratio of signal power versus pump power) vs. pump power.
the signal power and the conversion efficiency (ratio of signal power versus pump power) of the optical parametric amplifier are shown as a function of pump power. At 2 W pump power, which corresponds to an intensity of 10.5 GW/cm2, the conversion efficiency reaches saturation at 23.5%, whereas the signal power is still increasing at increasing pump power. However, we restrict the pump power to 2 W in order to remain well below the damage threshold of the PPLN crystal.

The OPA signal wavelength is continuously tunable between 1380 and 1830 nm, which corresponds to idler wavelengths from 2.41 to 4.22 µm, by changing the poling period of the crystal (28.0 to 31.0 µm in 0.5 µm steps) and by changing the crystal temperature between 20 and 200 °C. The tuning behavior is shown in Fig. 3
Fig. 3 Temperature tuning of signal wavelength. We used a 5 mm long PPLN crystal. The signal wavelength is continuously tunable between 1380 and 1830 nm.
.

The signal and idler spectra measured at room temperature are shown in Figs. 4
Fig. 4 OPA signal spectra and supercontinuum spectrum of the tapered fiber. The solid lines correspond to the experimental results. The dashed lines depict spectra from a numerical simulation. At room temperature the signal wavelength with PPLN is tunable between 1380 and 1640 nm.
and 5
Fig. 5 OPA idler spectra. The solid lines correspond to the experimental results. The dashed lines depict spectra from a numerical simulation. At room temperature the idler wavelength with PPLN is tunable between 3.04 and 4.16 µm.
, respectively. In Fig. 4 the supercontinuum seed of the tapered fiber is also depicted on a logarithmic scale. We exceed 325 mW over the whole signal range with a maximum power of 540 mW at 1400 nm, and we exceed 140 mW over the whole idler range with a maximum power of 220 mW at 3.06 µm. The pump power was set to 2 W to remain below the damage threshold of the PPLN crystal. However, using the maximum available pump power of 4 W, signal powers up to 800 mW were reached.

The signal spectra are broader at longer wavelengths, with 9 nm FWHM at 1400 nm and 48 nm FWHM at 1640 nm. However, the width of the idler spectra is smaller at longer wavelengths (210 nm FWHM at 3000 nm and 110 nm FWHM at 4100 nm).

The dashed lines depict spectra from the numerical solution of a χ(2) Nonlinear Envelope Equation [24

24. M. Conforti, F. Baronio, and C. De Angelis, “Nonlinear envelope equation for broadband optical pulses in quadratic media,” Phys. Rev. A 81(5), 053841 (2010). [CrossRef]

]. The agreement between the simulation, which uses the actual experimental parameters, and the measurement is quite good. For the longer signal wavelengths the simulation predicts somewhat broader spectra than the measurements. Angular dispersion due to focusing into the crystal might account for this deviation.

The autocorrelation indicates chirped signal pulses with durations in the range of a few hundred femtoseconds, with shorter pulse durations at shorter wavelengths. An example of an autocorrelation is shown in Fig. 6
Fig. 6 Autocorrelation and Fourier limit for the signal pulse at 1470 nm (6800 cm−1) wavelength.
. In this case, the signal pulse duration is 110 fs, while the Fourier-limited signal pulse duration is 45 fs. The chirp is introduced due to the propagation in the 8 cm long tapered fiber. We did not compress the pulses, but in principle the chirp could be compensated by a prism sequence or chirped mirrors.

To generate mid-IR radiation at longer wavelengths, we used a 1 mm or 2 mm long gallium selenide (GaSe) crystal instead of the PPLN crystal. We performed type I phase matching (e – o → o) and the pump power was set to 4 W. Apart from that, the setup remains the same as shown in Fig. 1 and as described above.

Broadband mid-IR idler pulses tunable from 4.85 to 9.33 µm (2060-1070 cm−1) are generated with up to 830 µW average power at 6.46 µm. The spectra are depicted in Fig. 7
Fig. 7 The mid-IR idler spectra are tunable between 4.85 and 9.33 µm. The solid lines correspond to the experimental results. The dashed lines depict spectra from a numerical simulation. We used a 2 mm long GaSe crystal.
and exhibit broadband behavior over the whole tuning range, with 130 nm (55 cm−1) FWHM at 4.85 µm and up to 640 nm (72 cm−1) FWHM at 9.33 µm. The dashed lines depict spectra from a simulation using the method described in [25

25. M. Conforti, F. Baronio, and C. De Angelis, “Modelling of ultrabroadband and single-cycle phenomena in anisotropic quadratic crystal,” J. Opt. Soc. Am. B 28(5), 1231–1237 (2011). [CrossRef]

]. The agreement between simulation and measurement is quite good.

The output power and the spectra of both schemes are temporally stable, as shown in Fig. 8
Fig. 8 Temporal stability of power and spectra (a) in the near-IR region using a 5 mm PPLN crystal and (b) in the mid-IR region using a 1 mm GaSe crystal. All measurements were performed over one hour.
, where the measurement time was one hour.

The power fluctuations in the near-IR region at 1390 nm are equal to 0.9% rms and the corresponding wavelength fluctuations are equal to 0.025% rms (0.34 nm). The power fluctuations in the mid-IR region at 6.32 µm are equal to 3.3% rms and the corresponding wavelength fluctuations are equal to 0.14% rms (8.9 nm).

4. Conclusion

To conclude, we demonstrated a femtosecond PPLN OPA with up to 540 mW average power and 41.7 MHz repetition rate that is tunable between 1380 and 1830 nm (signal) and 2.41 to 4.22 µm (idler), pumped by an Yb:KGW laser oscillator and seeded by a fiber-based supercontinuum. By using a GaSe crystal instead of PPLN, we generated broadband mid-IR idler radiation tunable between 4.85 and 9.33 µm. Our source is compact and cost-efficient and has the potential to replace more complex Ti:sapphire/OPO systems for ultrafast spectroscopy and mid-IR applications, such as broadband gas sensing and nano-spectroscopy.

Acknowledgments

We acknowledge financial support from Baden-Württemberg-Stiftung, MWK Stuttgart, Deutsche Forschungsgemeinschaft (SPP1391), and the Bundesministerium für Bildung und Forschung (3N10146). This work was supported by the German Research Foundation (DFG) within the funding program Open Access Publishing.

References and links

1.

G. Cerullo and S. De Silvestri, “Ultrafast optical parametric amplifiers,” Rev. Sci. Instrum. 74(1), 1–18 (2003). [CrossRef]

2.

T. Südmeyer, J. Aus der Au, R. Paschotta, U. Keller, P. G. R. Smith, G. W. Ross, and D. C. Hanna, “Femtosecond fiber-feedback optical parametric oscillator,” Opt. Lett. 26(5), 304–306 (2001). [CrossRef] [PubMed]

3.

F. Adler, K. C. Cossel, M. J. Thorpe, I. Hartl, M. E. Fermann, and J. Ye, “Phase-stabilized, 1.5 W frequency comb at 2.8-4.8 microm,” Opt. Lett. 34(9), 1330–1332 (2009). [CrossRef] [PubMed]

4.

R. Hegenbarth, A. Steinmann, G. Tóth, J. Hebling, and H. Giessen, “Two-color femtosecond optical parametric oscillator with 1.7 W output pumped by a 7.4 W Yb:KGW laser,” J. Opt. Soc. Am. B 28(5), 1344–1352 (2011). [CrossRef]

5.

D. Brida, M. Marangoni, C. Manzoni, S. D. Silvestri, and G. Cerullo, “Two-optical-cycle pulses in the mid-infrared from an optical parametric amplifier,” Opt. Lett. 33(24), 2901–2903 (2008). [CrossRef] [PubMed]

6.

O. D. Mücke, D. Sidorov, P. Dombi, A. Pugžlys, A. Baltuška, S. Ališauskas, V. Smilgevičius, J. Pocius, L. Giniūnas, R. Danielius, and N. Forget, “Scalable Yb-MOPA-driven carrier-envelope phase-stable few-cycle parametric amplifier at 1.5 microm,” Opt. Lett. 34(2), 118–120 (2009). [CrossRef] [PubMed]

7.

F. Silva, P. K. Bates, A. Esteban-Martin, M. Ebrahim-Zadeh, and J. Biegert, “High-average-power, carrier-envelope phase-stable, few-cycle pulses at 2.1 μm from a collinear BiB3O6 optical parametric amplifier,” Opt. Lett. 37(5), 933–935 (2012). [CrossRef] [PubMed]

8.

A. Killi, A. Steinmann, G. Palmer, U. Morgner, H. Bartelt, and J. Kobelke, “Megahertz optical parametric amplifier pumped by a femtosecond oscillator,” Opt. Lett. 31(1), 125–127 (2006). [CrossRef] [PubMed]

9.

A. Steinmann, A. Killi, G. Palmer, T. Binhammer, and U. Morgner, “Generation of few-cycle pulses directly from a MHz-NOPA,” Opt. Express 14(22), 10627–10630 (2006). [CrossRef] [PubMed]

10.

M. Marangoni, R. Osellame, R. Ramponi, G. Cerullo, A. Steinmann, and U. Morgner, “Near-infrared optical parametric amplifier at 1 MHz directly pumped by a femtosecond oscillator,” Opt. Lett. 32(11), 1489–1491 (2007). [CrossRef] [PubMed]

11.

T. V. Andersen, O. Schmidt, C. Bruchmann, J. Limpert, C. Aguergaray, E. Cormier, and A. Tünnermann, “High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier,” Opt. Express 14(11), 4765–4773 (2006). [CrossRef] [PubMed]

12.

C. Schriever, S. Lochbrunner, P. Krok, and E. Riedle, “Tunable pulses from below 300 to 970 nm with durations down to 14 fs based on a 2 MHz ytterbium-doped fiber system,” Opt. Lett. 33(2), 192–194 (2008). [CrossRef] [PubMed]

13.

Y.-W. Tzeng, Y.-Y. Lin, C.-H. Huang, J.-M. Liu, H.-C. Chui, H.-L. Liu, J. M. Stone, J. C. Knight, and S.-W. Chu, “Broadband tunable optical parametric amplification from a single 50 MHz ultrafast fiber laser,” Opt. Express 17(9), 7304–7309 (2009). [CrossRef] [PubMed]

14.

A. Schliesser, N. Picqué, and T. W. Hänsch, “Mid-infrared frequency combs,” Nat. Photonics 6(7), 440–449 (2012). [CrossRef]

15.

F. Huth, M. Schnell, J. Wittborn, N. Ocelic, and R. Hillenbrand, “Infrared-spectroscopic nanoimaging with a thermal source,” Nat. Mater. 10(5), 352–356 (2011). [CrossRef] [PubMed]

16.

S. Marzenell, R. Beigang, and R. Wallenstein, “Synchronously pumped femtosecond optical parametric oscillator based on AgGaSe2 tunable from 2 µm to 8 µm,” Appl. Phys. B 69(5-6), 423–428 (1999). [CrossRef]

17.

R. Hegenbarth, A. Steinmann, S. Sarkisov, and H. Giessen, “Milliwatt-level mid-infrared (10.5-16.5 μm) difference frequency generation with a femtosecond dual-signal-wavelength optical parametric oscillator,” Opt. Lett. 37(17), 3513–3515 (2012). [CrossRef] [PubMed]

18.

C. Erny, K. Moutzouris, J. Biegert, D. Kühlke, F. Adler, A. Leitenstorfer, and U. Keller, “Mid-infrared difference-frequency generation of ultrashort pulses tunable between 3.2 and 4.8 microm from a compact fiber source,” Opt. Lett. 32(9), 1138–1140 (2007). [CrossRef] [PubMed]

19.

T. W. Neely, T. A. Johnson, and S. A. Diddams, “High-power broadband laser source tunable from 3.0 μm to 4.4 μm based on a femtosecond Yb:fiber oscillator,” Opt. Lett. 36(20), 4020–4022 (2011). [CrossRef] [PubMed]

20.

A. Ruehl, A. Gambetta, I. Hartl, M. E. Fermann, K. S. E. Eikema, and M. Marangoni, “Widely-tunable mid-infrared frequency comb source based on difference frequency generation,” Opt. Lett. 37(12), 2232–2234 (2012). [CrossRef] [PubMed]

21.

C. R. Phillips, J. Jiang, C. Mohr, A. C. Lin, C. Langrock, M. Snure, D. Bliss, M. Zhu, I. Hartl, J. S. Harris, M. E. Fermann, and M. M. Fejer, “Widely tunable midinfrared difference frequency generation in orientation-patterned GaAs pumped with a femtosecond Tm-fiber system,” Opt. Lett. 37(14), 2928–2930 (2012). [CrossRef] [PubMed]

22.

A. Steinmann, B. Metzger, R. Hegenbarth, and H. Giessen, “Compact 7.4 W femtosecond oscillator for white-light generation and nonlinear microscopy,” Conference on Lasers and Electro-Optics, OSA Technical Digest (CD) (Optical Society of America, 2011), paper CThAA5.

23.

B. Metzger, A. Steinmann, F. Hoos, S. Pricking, and H. Giessen, “Compact laser source for high-power white-light and widely tunable sub 65 fs laser pulses,” Opt. Lett. 35(23), 3961–3963 (2010). [CrossRef] [PubMed]

24.

M. Conforti, F. Baronio, and C. De Angelis, “Nonlinear envelope equation for broadband optical pulses in quadratic media,” Phys. Rev. A 81(5), 053841 (2010). [CrossRef]

25.

M. Conforti, F. Baronio, and C. De Angelis, “Modelling of ultrabroadband and single-cycle phenomena in anisotropic quadratic crystal,” J. Opt. Soc. Am. B 28(5), 1231–1237 (2011). [CrossRef]

OCIS Codes
(190.4360) Nonlinear optics : Nonlinear optics, devices
(190.4970) Nonlinear optics : Parametric oscillators and amplifiers

ToC Category:
Nonlinear Optics

History
Original Manuscript: March 6, 2013
Revised Manuscript: April 18, 2013
Manuscript Accepted: April 27, 2013
Published: May 3, 2013

Citation
Joachim Krauth, Andy Steinmann, Robin Hegenbarth, Matteo Conforti, and Harald Giessen, "Broadly tunable femtosecond near- and mid-IR source by direct pumping of an OPA with a 41.7 MHz Yb:KGW oscillator," Opt. Express 21, 11516-11522 (2013)
http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-21-9-11516


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. G. Cerullo and S. De Silvestri, “Ultrafast optical parametric amplifiers,” Rev. Sci. Instrum.74(1), 1–18 (2003). [CrossRef]
  2. T. Südmeyer, J. Aus der Au, R. Paschotta, U. Keller, P. G. R. Smith, G. W. Ross, and D. C. Hanna, “Femtosecond fiber-feedback optical parametric oscillator,” Opt. Lett.26(5), 304–306 (2001). [CrossRef] [PubMed]
  3. F. Adler, K. C. Cossel, M. J. Thorpe, I. Hartl, M. E. Fermann, and J. Ye, “Phase-stabilized, 1.5 W frequency comb at 2.8-4.8 microm,” Opt. Lett.34(9), 1330–1332 (2009). [CrossRef] [PubMed]
  4. R. Hegenbarth, A. Steinmann, G. Tóth, J. Hebling, and H. Giessen, “Two-color femtosecond optical parametric oscillator with 1.7 W output pumped by a 7.4 W Yb:KGW laser,” J. Opt. Soc. Am. B28(5), 1344–1352 (2011). [CrossRef]
  5. D. Brida, M. Marangoni, C. Manzoni, S. D. Silvestri, and G. Cerullo, “Two-optical-cycle pulses in the mid-infrared from an optical parametric amplifier,” Opt. Lett.33(24), 2901–2903 (2008). [CrossRef] [PubMed]
  6. O. D. Mücke, D. Sidorov, P. Dombi, A. Pugžlys, A. Baltuška, S. Ališauskas, V. Smilgevičius, J. Pocius, L. Giniūnas, R. Danielius, and N. Forget, “Scalable Yb-MOPA-driven carrier-envelope phase-stable few-cycle parametric amplifier at 1.5 microm,” Opt. Lett.34(2), 118–120 (2009). [CrossRef] [PubMed]
  7. F. Silva, P. K. Bates, A. Esteban-Martin, M. Ebrahim-Zadeh, and J. Biegert, “High-average-power, carrier-envelope phase-stable, few-cycle pulses at 2.1 μm from a collinear BiB3O6 optical parametric amplifier,” Opt. Lett.37(5), 933–935 (2012). [CrossRef] [PubMed]
  8. A. Killi, A. Steinmann, G. Palmer, U. Morgner, H. Bartelt, and J. Kobelke, “Megahertz optical parametric amplifier pumped by a femtosecond oscillator,” Opt. Lett.31(1), 125–127 (2006). [CrossRef] [PubMed]
  9. A. Steinmann, A. Killi, G. Palmer, T. Binhammer, and U. Morgner, “Generation of few-cycle pulses directly from a MHz-NOPA,” Opt. Express14(22), 10627–10630 (2006). [CrossRef] [PubMed]
  10. M. Marangoni, R. Osellame, R. Ramponi, G. Cerullo, A. Steinmann, and U. Morgner, “Near-infrared optical parametric amplifier at 1 MHz directly pumped by a femtosecond oscillator,” Opt. Lett.32(11), 1489–1491 (2007). [CrossRef] [PubMed]
  11. T. V. Andersen, O. Schmidt, C. Bruchmann, J. Limpert, C. Aguergaray, E. Cormier, and A. Tünnermann, “High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier,” Opt. Express14(11), 4765–4773 (2006). [CrossRef] [PubMed]
  12. C. Schriever, S. Lochbrunner, P. Krok, and E. Riedle, “Tunable pulses from below 300 to 970 nm with durations down to 14 fs based on a 2 MHz ytterbium-doped fiber system,” Opt. Lett.33(2), 192–194 (2008). [CrossRef] [PubMed]
  13. Y.-W. Tzeng, Y.-Y. Lin, C.-H. Huang, J.-M. Liu, H.-C. Chui, H.-L. Liu, J. M. Stone, J. C. Knight, and S.-W. Chu, “Broadband tunable optical parametric amplification from a single 50 MHz ultrafast fiber laser,” Opt. Express17(9), 7304–7309 (2009). [CrossRef] [PubMed]
  14. A. Schliesser, N. Picqué, and T. W. Hänsch, “Mid-infrared frequency combs,” Nat. Photonics6(7), 440–449 (2012). [CrossRef]
  15. F. Huth, M. Schnell, J. Wittborn, N. Ocelic, and R. Hillenbrand, “Infrared-spectroscopic nanoimaging with a thermal source,” Nat. Mater.10(5), 352–356 (2011). [CrossRef] [PubMed]
  16. S. Marzenell, R. Beigang, and R. Wallenstein, “Synchronously pumped femtosecond optical parametric oscillator based on AgGaSe2 tunable from 2 µm to 8 µm,” Appl. Phys. B69(5-6), 423–428 (1999). [CrossRef]
  17. R. Hegenbarth, A. Steinmann, S. Sarkisov, and H. Giessen, “Milliwatt-level mid-infrared (10.5-16.5 μm) difference frequency generation with a femtosecond dual-signal-wavelength optical parametric oscillator,” Opt. Lett.37(17), 3513–3515 (2012). [CrossRef] [PubMed]
  18. C. Erny, K. Moutzouris, J. Biegert, D. Kühlke, F. Adler, A. Leitenstorfer, and U. Keller, “Mid-infrared difference-frequency generation of ultrashort pulses tunable between 3.2 and 4.8 microm from a compact fiber source,” Opt. Lett.32(9), 1138–1140 (2007). [CrossRef] [PubMed]
  19. T. W. Neely, T. A. Johnson, and S. A. Diddams, “High-power broadband laser source tunable from 3.0 μm to 4.4 μm based on a femtosecond Yb:fiber oscillator,” Opt. Lett.36(20), 4020–4022 (2011). [CrossRef] [PubMed]
  20. A. Ruehl, A. Gambetta, I. Hartl, M. E. Fermann, K. S. E. Eikema, and M. Marangoni, “Widely-tunable mid-infrared frequency comb source based on difference frequency generation,” Opt. Lett.37(12), 2232–2234 (2012). [CrossRef] [PubMed]
  21. C. R. Phillips, J. Jiang, C. Mohr, A. C. Lin, C. Langrock, M. Snure, D. Bliss, M. Zhu, I. Hartl, J. S. Harris, M. E. Fermann, and M. M. Fejer, “Widely tunable midinfrared difference frequency generation in orientation-patterned GaAs pumped with a femtosecond Tm-fiber system,” Opt. Lett.37(14), 2928–2930 (2012). [CrossRef] [PubMed]
  22. A. Steinmann, B. Metzger, R. Hegenbarth, and H. Giessen, “Compact 7.4 W femtosecond oscillator for white-light generation and nonlinear microscopy,” Conference on Lasers and Electro-Optics, OSA Technical Digest (CD) (Optical Society of America, 2011), paper CThAA5.
  23. B. Metzger, A. Steinmann, F. Hoos, S. Pricking, and H. Giessen, “Compact laser source for high-power white-light and widely tunable sub 65 fs laser pulses,” Opt. Lett.35(23), 3961–3963 (2010). [CrossRef] [PubMed]
  24. M. Conforti, F. Baronio, and C. De Angelis, “Nonlinear envelope equation for broadband optical pulses in quadratic media,” Phys. Rev. A81(5), 053841 (2010). [CrossRef]
  25. M. Conforti, F. Baronio, and C. De Angelis, “Modelling of ultrabroadband and single-cycle phenomena in anisotropic quadratic crystal,” J. Opt. Soc. Am. B28(5), 1231–1237 (2011). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited