Abstract
We present experiments that show that gray tracking modifies the parametric gain and the generated wavelengths of a KTP optical parametric oscillator pumped at 532 nm near degeneracy. These perturbations occur over a limited range of pump intensity. We propose a satisfactory model that takes into account photochromic damage, the thermo-optical effect, and the combined processes of creation and saturation of a two-photon absorber at 532 nm. The temperature dependence of Sellmeier equations of KTP is also established at 20–200 °C.
© 2000 Optical Society of America
Full Article | PDF ArticleMore Like This
V. Pasiskevicius, H. Karlsson, F. Laurell, R. Butkus, V. Smilgevicius, and A. Piskarskas
Opt. Lett. 26(10) 710-712 (2001)
Robert G. Batchko, Dennis R. Weise, Tomas Plettner, Gregory D. Miller, Martin M. Fejer, and Robert L. Byer
Opt. Lett. 23(3) 168-170 (1998)
A. Garashi, A. Arie, A. Skliar, and G. Rosenman
Opt. Lett. 23(22) 1739-1741 (1998)