OSA's Digital Library

Optics Letters

Optics Letters

| RAPID, SHORT PUBLICATIONS ON THE LATEST IN OPTICAL DISCOVERIES

  • Editor: Alan E. Willner
  • Vol. 38, Iss. 16 — Aug. 15, 2013
  • pp: 2997–3000

Rapid time-gated polarimetric Stokes imaging using photoelastic modulators

Sanaz Alali, Tianyu Yang, and I. Alex Vitkin  »View Author Affiliations


Optics Letters, Vol. 38, Issue 16, pp. 2997-3000 (2013)
http://dx.doi.org/10.1364/OL.38.002997


View Full Text Article

Enhanced HTML    Acrobat PDF (481 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We report a rapid time-gated full Stokes imaging approach without mechanically moving parts, which is well-suited for biomedical applications, using two photoelastic modulators (PEMs). A charge-coupled device (CCD) with microsecond time-gating capability was used to acquire the images. To synchronize the CCD with the PEMs, thus gaining signal-to-noise ratio advantage, a field programmable gate array was employed. After calibration, an evolutionary algorithm was used to select four time points from which the full Stokes vector can be recovered. Using the images taken by the camera at these four times (in 80ms), the images of the full Stokes vectors of different incident polarization states were accurately derived.

© 2013 Optical Society of America

OCIS Codes
(110.5405) Imaging systems : Polarimetric imaging
(170.6935) Medical optics and biotechnology : Tissue characterization

ToC Category:
Imaging Systems

History
Original Manuscript: May 31, 2013
Revised Manuscript: July 9, 2013
Manuscript Accepted: July 9, 2013
Published: August 7, 2013

Virtual Issues
Vol. 8, Iss. 9 Virtual Journal for Biomedical Optics

Citation
Sanaz Alali, Tianyu Yang, and I. Alex Vitkin, "Rapid time-gated polarimetric Stokes imaging using photoelastic modulators," Opt. Lett. 38, 2997-3000 (2013)
http://www.opticsinfobase.org/ol/abstract.cfm?URI=ol-38-16-2997


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. V. V. Tuchin, Tissue Optics, 2nd ed. (SPIE, 2007).
  2. S. L. Jacques, J. R. Roman, and K. Lee, Lasers Surg. Med. 26, 119 (2000). [CrossRef]
  3. H. Luo, K. Oka, E. DeHoog, M. Kudenov, J. Schiewgerling, and E. L. Dereniak, Appl. Opt. 47, 4413 (2008). [CrossRef]
  4. M. W. Kudenov, M. J. Escuti, N. Hagen, E. L. Dereniak, and K. Oka, Opt. Lett. 37, 1367 (2012). [CrossRef]
  5. L. M. S. Aas, P. G. Ellingsen, M. Kildemo, and M. Lindgren, J. Mod. Opt. 57, 1603 (2010). [CrossRef]
  6. A. Pierangelo, S. Manhas, A. Benali, C. Fallet, J. L. Totobenazara, M. R. Antonelli, T. Novikova, B. Gayet, A. De Martino, and P. Validire, J. Biomed. Opt. 18, 046014 (2013). [CrossRef]
  7. C. Y. Han and Y. F. Chao, Rev. Sci. Instrum. 77, 023107 (2006). [CrossRef]
  8. D. J. Diner, A. Davis, B. Hancock, S. Geier, B. Rheingans, V. Jovanovic, M. Bull, D. M. Rider, R. A. Chipman, A. B. Mahler, and S. C. McClain, Appl. Opt. 49, 2929 (2010). [CrossRef]
  9. R. C. Thompson, J. R. Bottiger, and E. S. Fry, Appl. Opt. 19, 1323 (1980). [CrossRef]
  10. O. Arteaga, J. Freudenthal, B. Wang, and B. Kahr, Appl. Opt. 51, 6805 (2012). [CrossRef]
  11. M. F. G. Wood, X. Guo, and I. A. Vitkin, J. Biomed. Opt. 12, 014029 (2007). [CrossRef]
  12. G. E. Jellison and F. A. Modine, Appl. Opt. 36, 8190 (1997). [CrossRef]
  13. K. M. Twietmeyer and R. A. Chipman, Opt. Express 16, 11589 (2008). [CrossRef]
  14. E. Compain, S. Poirier, and B. Drévillon, Appl. Opt. 38, 3490 (1999). [CrossRef]
  15. L. M. S. Aas, P. G. Ellingsen, B. E. Fladmark, P. A. Letnes, and M. Kildemo, Opt. Express 21, 8753 (2013). [CrossRef]
  16. A. Ambirajan and D. C. Look, Opt. Eng. 34, 1656 (1995). [CrossRef]
  17. J. S. Tyo, Opt. Lett. 25, 1198 (2000). [CrossRef]
  18. F. Massoumian, S. Alali, and T. Mansouri, Opt. Lett. 34, 67 (2009). [CrossRef]
  19. W. F. Cheong, S. A. Prahl, and A. J. Welch, IEEE J. Quantum Electron. 26, 2166 (1990). [CrossRef]
  20. S. Alali, M. Ahmad, M. A. Kim, N. Vurgun, M. F. Wood, and I. A. Vitkin, J. Biomed. Opt. 17, 045004 (2012). [CrossRef]
  21. S. Alali and I. A. Vitkin, “Optimization of rapid Mueller matrix imaging of turbid media using four photoelastic modulators without mechanically moving parts,” Opt. Eng., submitted for publication.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: AVI (8695 KB)     
» Media 2: AVI (8690 KB)     

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited