Abstract
In this work, an optimum plane selection methodology is reported that can be applied to a wide range of single-beam phase retrieval techniques, based on the contrast transfer function. It is shown that the optimum measurement distances obtained by this method form a geometric series that maximizes the range of spatial frequencies to be recovered using a minimum number of planes. This allows a noise-robust phase reconstruction that does not rely on regularization techniques, i.e., an extensive search for a regularization parameter is avoided. Measurement systems that employ this optimization criteria give an instant deterministic noise-robust phase reconstruction with higher accuracy, and enable the phase retrieval of the entire object spectrum, including lower frequency components.
© 2013 Optical Society of America
Full Article | PDF ArticleMore Like This
Pablo Villanueva-Perez, Filippo Arcadu, Peter Cloetens, and Marco Stampanoni
Opt. Lett. 42(6) 1133-1136 (2017)
J. Martinez-Carranza, K. Falaggis, and T. Kozacki
Appl. Opt. 53(30) 7050-7058 (2014)
Chen Bai, Meiling Zhou, Junwei Min, Shipei Dang, Xianghua Yu, Peng Zhang, Tong Peng, and Baoli Yao
Opt. Lett. 44(21) 5141-5144 (2019)