Calibration-free B-scan images produced by master/slave optical coherence tomography

Adrian Bradu and Adrian Gh. Podoleanu  »View Author Affiliations


Optics Letters, Vol. 39, Issue 3, pp. 450-453 (2014)
http://dx.doi.org/10.1364/OL.39.000450


View Full Text Article

Enhanced HTML    Acrobat PDF (282 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We report on a novel method to produce B-scan images in spectral domain optical coherence tomography (SD-OCT). The method proceeds in two steps. In the first step, using a mirror in the sample arm of the interferometer, channelled spectra are acquired for different values of the optical path difference (OPD) and stored as masks. In the second step, the mirror is replaced with an object and the captured channelled spectrum is correlated with each mask, providing the interference strength from the OPD value used to collect the respective mask. Such a procedure does not require data organized in equal frequency slots, and therefore there is no need for resampling as practiced in the conventional fast Fourier transform (FFT)-based SD-OCT technology. We show that the sensitivity drop-off versus OPD and the quality of B-scan images of the novel method are similar to those obtained in the conventional FFT-based SD-OCT, using spectral data linearly organized in frequency.

© 2014 Optical Society of America

OCIS Codes
(110.4500) Imaging systems : Optical coherence tomography
(170.0110) Medical optics and biotechnology : Imaging systems
(100.3175) Image processing : Interferometric imaging

ToC Category:
Imaging Systems

History
Original Manuscript: August 29, 2013
Revised Manuscript: November 8, 2013
Manuscript Accepted: December 9, 2013
Published: January 20, 2014

Virtual Issues
Vol. 9, Iss. 4 Virtual Journal for Biomedical Optics

Citation
Adrian Bradu and Adrian Gh. Podoleanu, "Calibration-free B-scan images produced by master/slave optical coherence tomography," Opt. Lett. 39, 450-453 (2014)
http://www.opticsinfobase.org/ol/abstract.cfm?URI=ol-39-3-450


Sort:  Author  |  Year  |  Journal  |  Reset  

References

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1. Fig. 2. Fig. 3.
 
Fig. 4.
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited