Molecular specificity in photoacoustic microscopy by time-resolved transient absorption

Not Accessible

Your library or personal account may give you access

Abstract

We have recently harnessed transient absorption, a resonant two-photon process, for ultrahigh resolution photoacoustic microscopy, achieving nearly an order of magnitude improvement in axial resolution. The axial resolution is optically constrained due to the two-photon process unlike traditional photoacoustic microscopy where the axial resolution is inversely proportional to the frequency bandwidth of the detector. As a resonant process, the arrival time of the two photons need not be instantaneous. Systematically recording the signal as a function of the delay between two pulses will result in the measurement of an exponential decay whose time constant is related to the molecular dynamics. This time constant, analogous to the fluorescence lifetime, but encompassing nonradiative decay as well, can be used to differentiate between molecular systems with overlapping absorption spectra. This is frequently the situation for closely related yet distinct molecules such as redox pairs. In order to enable the measure of the exponential decay, we have reconfigured our transient absorption ultrasonic microscopy (TAUM) system to incorporate two laser sources with precisely controlled pulse trains. The system was tested by measuring Rhodamine 6G, an efficient laser dye where the molecular dynamics are dominated by the fluorescence pathway. As expected, the measured exponential time constant or ground state recovery time, 3.3±0.7ns, was similar to the well-known fluorescence lifetime, 4.11±0.05ns. Oxy- and deoxy-hemoglobin are the quintessential pair whose relative concentration is related to the local blood oxygen saturation. We have measured the ground state recovery times of these two species in fully oxygenated and deoxygenated bovine whole blood to be 3.7±0.8ns and 7.9±1.0ns, respectively. Hence, even very closely related pairs of molecules may be differentiated with this technique.

© 2014 Optical Society of America

Full Article  |  PDF Article
More Like This
Simplified method for ultra high-resolution photoacoustic microscopy via transient absorption

Scott P. Mattison and Brian E. Applegate
Opt. Lett. 39(15) 4474-4477 (2014)

Ultrahigh resolution photoacoustic microscopy via transient absorption

Ryan L. Shelton and Brian E. Applegate
Biomed. Opt. Express 1(2) 676-686 (2010)

Single-wavelength functional photoacoustic microscopy in biological tissue

Amos Danielli, Christopher P. Favazza, Konstantin Maslov, and Lihong V. Wang
Opt. Lett. 36(5) 769-771 (2011)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (3)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (1)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.