Hyperspectral Confocal Fluorescence Imaging: Exploring Alternative Multivariate Curve Resolution Approaches

Not Accessible

Your library or personal account may give you access

Abstract

Hyperspectral confocal fluorescence microscopy, when combined with multivariate curve resolution (MCR), provides a powerful new tool for improved quantitative imaging of multi-fluorophore samples. Generally, fully non-negatively constrained models are used in the constrained alternating least squares MCR analyses of hyperspectral images since real emission components are expected to have non-negative pure emission spectra and concentrations. However, in this paper, we demonstrate four separate cases in which partially constrained models are preferred over the fully constrained MCR models. These partially constrained MCR models can sometimes be preferred when system artifacts are present in the data or where small perturbations of the major emission components are present due to environmental effects or small geometric changes in the fluorescing species. Here we demonstrate that in the cases of hyperspectral images obtained from multicomponent spherical beads, autofluorescence from fixed lung epithelial cells, fluorescence of quantum dots in aqueous solutions, and images of mercurochrome-stained endosperm portions of a wild-type corn seed, these alternative, partially constrained MCR analyses provide improved interpretability of the MCR solutions. Often the system artifacts or environmental effects are more readily described as first and/or second derivatives of the main emission components in these alternative MCR solutions since they indicate spectral shifts and/or spectral broadening or narrowing of the emission bands, respectively. Thus, this paper serves to demonstrate the need to test alternative partially constrained models when analyzing hyperspectral images with MCR methods.

PDF Article
More Like This
Hyperspectral confocal microscope

Michael B. Sinclair, David M. Haaland, Jerilyn A. Timlin, and Howland D. T. Jones
Appl. Opt. 45(24) 6283-6291 (2006)

Confocal hyperspectral microscopic imager for the detection and classification of individual microalgae

Jing Luo, Haodong Zhang, Erik Forsberg, Saimei Hou, Shuo Li, Zhanpeng Xu, Xiang Chen, Xiaohong Sun, and Sailing He
Opt. Express 29(23) 37281-37301 (2021)

Hyperspectral imaging in highly scattering media by the spectral phasor approach using two filters

Alexander Dvornikov and Enrico Gratton
Biomed. Opt. Express 9(8) 3503-3511 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved