OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 6, Iss. 1 — Jan. 3, 2011

Referencing techniques for the analog mean-delay method in fluorescence lifetime imaging

Young Jae Won, Sucbei Moon, Won-Taek Han, and Dug Young Kim  »View Author Affiliations


JOSA A, Vol. 27, Issue 11, pp. 2402-2410 (2010)
http://dx.doi.org/10.1364/JOSAA.27.002402


View Full Text Article

Enhanced HTML    Acrobat PDF (614 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

The analog mean-delay (AMD) method is a new powerful alternative method in determining the lifetime of a fluorescence molecule for high-speed confocal fluorescence lifetime imaging microscopy. Even though the photon economy and the lifetime precision of the AMD method are proven to be as good as those of the state-of-the-art time-correlated single photon counting method, there have been some speculations and concerns about the accuracy of this method with respect to the absolute lifetime value of a fluorescence probe. In the AMD method, the temporal waveform of an emitted fluorescence signal is directly recorded with a slow digitizer whose bandwidth is much lower than the temporal resolution of the lifetime to be measured. We have found that the drifts and the fluctuations of the absolute zero position in a measured temporal waveform are the major problems in the AMD method. We have proposed electrical and optical referencing techniques that may suppress these errors. It is shown that there may exist more than 2 ns drift in a measured temporal waveform during the period of the first 12 min after electronic components are turned on. The standard deviation of a measured lifetime after this warm-up period can be as large as 51 ps without any referencing technique. We have shown that this error can be reduced to 9 ps with our electronic referencing technique. It is demonstrated that this can be further reduced to 4 ps by the optical referencing technique we have introduced.

© 2010 Optical Society of America

OCIS Codes
(000.2170) General : Equipment and techniques
(170.1790) Medical optics and biotechnology : Confocal microscopy
(170.2520) Medical optics and biotechnology : Fluorescence microscopy
(170.3650) Medical optics and biotechnology : Lifetime-based sensing
(170.6920) Medical optics and biotechnology : Time-resolved imaging

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: July 2, 2010
Revised Manuscript: September 8, 2010
Manuscript Accepted: September 8, 2010
Published: October 15, 2010

Virtual Issues
Vol. 6, Iss. 1 Virtual Journal for Biomedical Optics

Citation
Young Jae Won, Sucbei Moon, Won-Taek Han, and Dug Young Kim, "Referencing techniques for the analog mean-delay method in fluorescence lifetime imaging," J. Opt. Soc. Am. A 27, 2402-2410 (2010)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=josaa-27-11-2402


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. V. Ntziachristos, “Fluorescence molecular imaging,” Annu. Rev. Biomed. Eng. 8, 1–33 (2006). [CrossRef] [PubMed]
  2. H. C. Gerristen, A. Draaijer, D. J. van den Heuvel, and A. V. Agronskaia, “Fluorescence lifetime imaging in scanning microscopy,” in Handbook of Biological Confocal Microscopy, 3rd ed., J.B.Pawley, ed. (Springer, 2006).
  3. R. Sanders, H. Gerritsen, A. Draaijer, P. Houpt, and Y. K. Levine, “Fluorescence lifetime imaging of free calcium in single cells,” Bioimaging 2, 131–138 (1994). [CrossRef]
  4. J. M. Vroom, K. J. de Grauw, H. C. Gerritsen, D. J. Bradshaw, P. D. Marsh, G. K. Watson, J. J. Birmingham, and C. Allison, “Depth penetration and detection of pH gradients in biofilms by two-photon excitation microscopy,” Appl. Environ. Microbiol. 65, 3502–3511 (1999). [PubMed]
  5. E. A. Jares-Erijman and T. M. Jovin, “FRET imaging,” Nat. Biotechnol. 21, 1387–1395 (2003). [CrossRef] [PubMed]
  6. D. K. Nair, M. Jose, T. Kuner, W. Zuschratter, and R. Hartig, “FRET-FLIM at nanometer spectral resolution from living cells,” Opt. Express 14, 12217–12229 (2006). [CrossRef] [PubMed]
  7. W. Zhong, M. Wu, C. Chang, K. A. Merrick, S. D. Merajver, and M. Mycek, “Picosecond-resolution fluorescence lifetime imaging microscopy: a useful tool for sensing molecular interactions in vivo via FRET,” Opt. Express 15, 18220–18235 (2007). [CrossRef] [PubMed]
  8. W. Becker, A. Bergmann, M. A. Hink, K. König, K. Benndorf, and C. Biskup, “Fluorescence lifetime imaging by time-correlated single-photon counting,” Microsc. Res. Tech. 63, 58–66 (2004). [CrossRef]
  9. T. H. Chia, A. Williamson, D. D. Spencer, and M. J. Levene, “Multiphoton fluorescence lifetime imaging of intrinsic fluorescence in human and rat brain tissue reveals spatially distinct NADH binding,” Opt. Express 16, 4237–4249 (2008). [CrossRef] [PubMed]
  10. H. C. Gerritsen, D. J. Van den Heuvel, and A. V. Agronskaia, “High-speed fluorescence lifetime imaging,” Proc. SPIE 5323, 77–87 (2004). [CrossRef]
  11. R. V. Krishnan, H. Saitoh, H. Terada, V. E. Centonze, and B. Herman, “Development of a multiphoton fluorescence lifetime imaging microscopy system using a streak camera,” Rev. Sci. Instrum. 74, 2714–2721 (2003). [CrossRef]
  12. A. V. Agronskaia, L. Tertoolen, and H. C. Gerritsen, “High frame rate fluorescence lifetime imaging,” J. Phys. D: Appl. Phys. 36, 1655–1662 (2003). [CrossRef]
  13. J. Requejo-Isidro, J. McGinty, I. Munro, D. S. Elson, N. P. Galletly, M. J. Lever, M. A. A. Neil, G. W. H. Stamp, P. M. W. French, P. A. Kellett, J. D. Hares, and A. K. L. Dymoke-Bradshaw, “High-speed wide-field time-gated endoscopic fluorescence-lifetime imaging,” Opt. Lett. 29, 2249–2251 (2004). [CrossRef] [PubMed]
  14. S. Moon, Y. Won, and D. Y. Kim, “Analog mean-delay method for high-speed fluorescence lifetime measurement,” Opt. Express 17, 2834–2849 (2009). [CrossRef] [PubMed]
  15. K. Carlsson and J. Philip, “Theoretical investigation of the signal-to-noise ratio for different fluorescence lifetime imaging techniques,” Proc. SPIE 4622, 1605–7422 (2002).
  16. J. Philip and K. Carlsson, “Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging,” J. Opt. Soc. Am. A 20, 368–379 (2003). [CrossRef]
  17. ISS, Inc., “Lifetime data of selected fluorophores,” http://www.iss.com/resources/fluorophores.html.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited