OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 8, Iss. 1 — Feb. 4, 2013

Computational modeling of optical projection tomographic microscopy using the finite difference time domain method

Ryan L. Coe and Eric J. Seibel  »View Author Affiliations


JOSA A, Vol. 29, Issue 12, pp. 2696-2707 (2012)
http://dx.doi.org/10.1364/JOSAA.29.002696


View Full Text Article

Enhanced HTML    Acrobat PDF (806 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We present a method for modeling image formation in optical projection tomographic microscopy (OPTM) using high numerical aperture (NA) condensers and objectives. Similar to techniques used in computed tomography, OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The model is capable of simulating axial scanning of a microscope objective to produce projections, which are reconstructed using filtered backprojection. Simulation of optical scattering in transmission optical microscopy is designed to analyze all aspects of OPTM image formation, such as degree of specimen staining, refractive-index matching, and objective scanning. In this preliminary work, a set of simulations is performed to examine the effect of changing the condenser NA, objective scan range, and complex refractive index on the final reconstruction of a microshell with an outer radius of 1.5 μm and an inner radius of 0.9 μm. The model lays the groundwork for optimizing OPTM imaging parameters and triaging efforts to further improve the overall system design. As the model is expanded in the future, it will be used to simulate a more realistic cell, which could lead to even greater impact.

© 2012 Optical Society of America

OCIS Codes
(000.4430) General : Numerical approximation and analysis
(110.2990) Imaging systems : Image formation theory
(180.6900) Microscopy : Three-dimensional microscopy
(290.0290) Scattering : Scattering
(050.1755) Diffraction and gratings : Computational electromagnetic methods

ToC Category:
Microscopy

History
Original Manuscript: September 21, 2012
Revised Manuscript: November 2, 2012
Manuscript Accepted: November 7, 2012
Published: November 30, 2012

Virtual Issues
Vol. 8, Iss. 1 Virtual Journal for Biomedical Optics

Citation
Ryan L. Coe and Eric J. Seibel, "Computational modeling of optical projection tomographic microscopy using the finite difference time domain method," J. Opt. Soc. Am. A 29, 2696-2707 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=josaa-29-12-2696


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. Q. Miao, A. P. Reeves, F. W. Patten, and E. J. Seibel, “Multimodal 3D imaging of cells and tissue: bridging the gap between clinical and research microscopy,” Ann. Biomed. Eng. 40, 263–276 (2012). [CrossRef]
  2. M. G. Meyer, M. Fauver, J. R. Rahn, T. Neumann, and F. W. Patten, “Automated cell analysis in 2D and 3D: a comparative study,” Pattern Recogn. 42, 141–146 (2009). [CrossRef]
  3. M. Fauver, E. J. Seibel, J. R. Rahn, M. G. Meyer, F. W. Patten, T. Neumann, and A. C. Nelson, “Three-dimensional imaging of single isolated cell nuclei using optical projection tomography,” Opt. Express 13, 4210–4223 (2005). [CrossRef]
  4. I. T. Young, “Quantitative microscopy,” IEEE Eng. Med. Biol. 15, 59–66 (1996). [CrossRef]
  5. N. N. Boustany, S. A. Boppart, and V. Backman, “Microscopic imaging and spectroscopy with scattered light,” Annu. Rev. Biomed. Eng. 12, 285–314 (2010). [CrossRef]
  6. H. Subramanian, H. K. Roy, P. Pradhan, M. J. Goldberg, J. Muldoon, R. E. Brand, C. Sturgis, T. Hensing, D. Ray, A. Bogojevic, J. Mohammed, J. Chang, and V. Backman, “Nanoscale cellular changes in field carcinogenesis detected by partial wave spectroscopy,” Cancer Res. 69, 5357–5363 (2009). [CrossRef]
  7. I. R. Çapoglu, C. A. White, J. D. Rogers, H. Subramanian, A. Taflove, and V. Backman, “Numerical simulation of partially coherent broadband optical imaging using the finite-difference time-domain method,” Opt. Lett. 36, 1596–1598 (2011). [CrossRef]
  8. C. Smithpeter, A. K. Dunn, R. Drezek, T. Collier, and R. Richards-Kortum, “Near real time confocal microscopy of cultured amelanotic cells: sources of signal, contrast agents and limits of contrast,” J. Biomed. Opt. 3, 429–436 (1998). [CrossRef]
  9. N. Nakajima, “Phase retrieval from a high-numerical-aperture intensity distribution by use of an aperture-array filter,” J. Opt. Soc. Am. A 26, 2172–2180 (2009). [CrossRef]
  10. M. Totzeck, “Numerical simulation of high-NA quantitative polarization microscopy and corresponding near-fields,” Optik 112, 399–406 (2001). [CrossRef]
  11. F. Slimani, G. Grehan, G. Gouesbet, and D. Allano, “Near-field Lorenz–Mie theory and its application to microholography,” Appl. Opt. 23, 4140–4148 (1984). [CrossRef]
  12. G. Gouesbet, “Generalized Lorenz–Mie theory and applications,” Part. Part. Syst. Charact. 11, 22–34 (1994). [CrossRef]
  13. P. Török, P. R. T. Munro, and E. E. Kriezis, “Rigorous near- to far-field transformation for vectorial diffraction calculations and its numerical implementation,” J. Opt. Soc. Am. A 23, 713–722 (2006). [CrossRef]
  14. I. R. Çapoglu, A. Taflove, and V. Backman, “Generation of an incident focused light pulse in FDTD,” Opt. Express 16, 19208–19220 (2008). [CrossRef]
  15. A. Taflove and S. C. Hagness,Computational Electrodynamics: The Finite-Difference Time-Domain Method (Artech House, 2005).
  16. R. L. Coe and E. J. Seibel, “Improved near-field calculations using vectorial diffraction integrals in the finite-difference time-domain method,” J. Opt. Soc. Am. A 28, 1776–1783 (2011). [CrossRef]
  17. P. R. T. Munro and P. Török, “Calculation of the image of an arbitrary vectorial electromagnetic field,” Opt. Express 15, 9293–9307 (2007). [CrossRef]
  18. J. B. Schneider and K. Abdijalilov, “Analytic field propagation TFSF boundary for FDTD problems involving planar interfaces: PECs, TE, and TM,” IEEE Trans. Antennas. Propag. 54, 2531–2542 (2006). [CrossRef]
  19. P. Török, P. R. T. Munro, and E. E. Kriezis, “High numerical aperture vectorial imaging in coherent optical microscopes,” Opt. Express 16, 507–523 (2008). [CrossRef]
  20. B. Richards and E. Wolf, “Electromagnetic diffraction in optical systems. II. Structure of the image field in an aplanatic system,” Proc. R. Soc. A 253, 358–379 (1959). [CrossRef]
  21. M. Born and E. Wolf, Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light (Pergamon, 1980).
  22. I. R. Capoglu, J. D. Rogers, A. Taflove, and V. Backman, “The microscope in a computer: Image synthesis from three-dimensional full-vector solutions of Maxwell’s equations at the nanometer scale,” Prog. Opt.57, 1–91 (2012). [CrossRef]
  23. K. Yee, “Numerical solution of initial boundary value problems involving Maxwell’s equations in isotropic media,” IEEE Trans. Antennas Propag. 14, 302–307 (1966). [CrossRef]
  24. J. P. Berenger, “A perfectly matched layer for the absorption of electromagnetic waves,” J. Comput. Phys. 114, 185–200 (1994). [CrossRef]
  25. J. A. Roden and S. D. Gedney, “Convolution PML (CPML): an efficient FDTD implementation of the CFS–PML for arbitrary media,” Microw. Opt. Technol. Lett. 27, 334–339 (2000). [CrossRef]
  26. D. Merewether, R. Fisher, and F. W. Smith, “On implementing a numeric Huygen’s source scheme in a finite difference program to illuminate scattering bodies,” IEEE Trans. Nucl. Sci. 27, 1829–1833 (1980). [CrossRef]
  27. T. Martin, “An improved near- to far-zone transformation for the finite-difference time-domain method,” IEEE Trans. Antennas Propag. 46, 1263–1271 (1998). [CrossRef]
  28. D. J. Robinson and J. B. Schneider, “On the use of the geometric mean in FDTD near-to-far-field transformations,” IEEE Trans. Antennas Propag. 55, 3204–3211 (2007). [CrossRef]
  29. T. Martin, “On the FDTD near-to-far-field transformations for weakly scattering objects,” IEEE Trans. Antennas Propag. 58, 2794–2795 (2010). [CrossRef]
  30. A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging (IEEE, 1988).
  31. M. G. L. Gustafsson, “Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy,” J. Microsc. 198, 82–87 (2000). [CrossRef]
  32. N. Martini, J. Bewersdorf, and S. W. Hell, “A new high-aperture glycerol immersion objective lens and its application to 3D-fluorescence microscopy,” J. Microsc. 206, 146–151 (2002). [CrossRef]
  33. X. Ma, J. Q. Lu, R. S. Brock, K. M. Jacobs, P. Yang, and X.-H. Hu, “Determination of complex refractive index of polystyrene microspheres from 370 to 1610 nm,” Phys. Med. Biol. 48, 4165–4172 (2003). [CrossRef]
  34. C. Guiffaut and K. Mahdjoubi, “Perfect wideband plane wave injector for FDTD method,” in Proceedings of IEEE Antennas Propagation Society International Symposium (IEEE, 2000), pp. 236–239.
  35. T. H. Chow, W. M. Lee, K. M. Tan, B. K. Ng, and C. J. R. Sheppard, “Resolving interparticle position and optical forces along the axial direction using optical coherence gating,” Appl. Phys. Lett. 97, 231113 (2010). [CrossRef]
  36. J. P. Brody and S. R. Quake, “A self-assembled microlensing rotational probe,” Appl. Phys. Lett. 74, 144–146 (1999). [CrossRef]
  37. J. J. Schwartz, S. Stavrakis, and S. R. Quake, “Colloidal lenses allow high-temperature single-molecule imaging and improve fluorophore photostability,” Nat. Nanotechnol. 5, 127–132 (2009). [CrossRef]
  38. W. Choi, C. Fang-Yen, K. Badizadegan, S. Oh, N. Lue, R. R. Dasari, and M. S. Feld, “Tomographic phase microscopy,” Nat. Methods 4, 717–719 (2007). [CrossRef]
  39. R. Drezek, A. Dunn, and R. Richards-Kortum, “Light scattering from cells: finite-difference time-domain simulations and goniometric measurements,” Appl. Opt. 38, 3651–3661 (1999). [CrossRef]
  40. R. Drezek, A. Dunn, and R. Richards-Kortum, “A pulsed finite-difference time-domain (FDTD) method for calculating light scattering from biological cells over broad wavelength ranges,” Opt. Express 6, 147–157 (2000). [CrossRef]
  41. H. Subramanian, P. Pradhan, Y. Liu, I. R. Capoglu, J. D. Rogers, H. K. Roy, R. E. Brand, and V. Backman, “Partial-wave microscopic spectroscopy detects subwavelength refractive index fluctuations: an application to cancer diagnosis,” Opt. Lett. 34, 518–520 (2009). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited