OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 7, Iss. 10 — Oct. 5, 2012

Enhancement of imaging depth of two-photon microscopy using pinholes: Analytical simulation and experiments

Woosub Song, Jihoon Lee, and Hyuk-Sang Kwon  »View Author Affiliations


Optics Express, Vol. 20, Issue 18, pp. 20605-20622 (2012)
http://dx.doi.org/10.1364/OE.20.020605


View Full Text Article

Enhanced HTML    Acrobat PDF (1545 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Achieving a greater imaging depth with two-photon fluorescence microscopy (TPFM) is mainly limited by out-of-focus fluorescence generated from both ballistic and scattered light excitation. We report on an improved signal-to-noise ratio (SNR) in a highly scattering medium as demonstrated by analytical simulation and experiments for TPFM. Our technique is based on out-of-focus rejection using a confocal pinhole. We improved the SNR by introducing the pinhole in the collection beam path. Using the radiative transfer theory and the ray-optics approach, we analyzed the effects of different sizes of pinholes on the generation of the fluorescent signal in the TPFM system. The analytical simulation was evaluated by comparing its results with the experimental results in a scattering medium. In a combined confocal pinhole and two-photon microscopy system, the imaging depth limit of approximately 5 scattering mean free paths (MFP) was found to have improved to 6.2 MFP.

© 2012 OSA

OCIS Codes
(110.2990) Imaging systems : Image formation theory
(170.3660) Medical optics and biotechnology : Light propagation in tissues
(190.4180) Nonlinear optics : Multiphoton processes
(110.0113) Imaging systems : Imaging through turbid media
(180.4315) Microscopy : Nonlinear microscopy

ToC Category:
Microscopy

History
Original Manuscript: June 18, 2012
Revised Manuscript: August 13, 2012
Manuscript Accepted: August 15, 2012
Published: August 23, 2012

Virtual Issues
Vol. 7, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Woosub Song, Jihoon Lee, and Hyuk-Sang Kwon, "Enhancement of imaging depth of two-photon microscopy using pinholes: Analytical simulation and experiments," Opt. Express 20, 20605-20622 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-20-18-20605


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. S. Paddock, “Tech.Sight. Optical sectioning--slices of life,” Science295(5558), 1319–1321 (2002). [CrossRef] [PubMed]
  2. J. A. Conchello and J. W. Lichtman, “Optical sectioning microscopy,” Nat. Methods2(12), 920–931 (2005). [CrossRef] [PubMed]
  3. F. Helmchen and W. Denk, “Deep tissue two-photon microscopy,” Nat. Methods2(12), 932–940 (2005). [CrossRef] [PubMed]
  4. W. R. Zipfel, R. M. Williams, and W. W. Webb, “Nonlinear magic: multiphoton microscopy in the biosciences,” Nat. Biotechnol.21(11), 1369–1377 (2003). [CrossRef] [PubMed]
  5. J. G. White and W. B. Amos, “Confocal microscopy comes of age,” Nature328(6126), 183–184 (1987). [CrossRef]
  6. W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science248(4951), 73–76 (1990). [CrossRef] [PubMed]
  7. V. V. Tuchin, Tissue optics: Light scattering methods and instruments for medical diagnosis (Springer-Verlag, 2006).
  8. J. B. Pawley, Handbook of Biological Confocal Microscopy (Springer, 2006).
  9. P. Theer and W. Denk, “On the fundamental imaging-depth limit in two-photon microscopy,” J. Opt. Soc. Am. A23(12), 3139–3149 (2006). [CrossRef] [PubMed]
  10. P. Theer, M. T. Hasan, and W. Denk, “Two-photon imaging to a depth of 1000 microm in living brains by use of a Ti:Al2O3 regenerative amplifier,” Opt. Lett.28(12), 1022–1024 (2003). [CrossRef] [PubMed]
  11. Y. L. Grand, A. Leray, T. Guilbert, and C. Odin, “Non-descanned versus descanned epifluorescence collection in two-photon microscopy: Experiments and Monte Carlo simulations,” Opt. Commun.281(21), 5480–5486 (2008).
  12. C. J. Engelbrecht, W. Göbel, and F. Helmchen, “Enhanced fluorescence signal in nonlinear microscopy through supplementary fiber-optic light collection,” Opt. Express17(8), 6421–6435 (2009). [CrossRef] [PubMed]
  13. R. Gauderon, P. B. Lukins, and C. J. Sheppard, “Effect of a confocal pinhole in two-photon microscopy,” Microsc. Res. Tech.47(3), 210–214 (1999). [CrossRef] [PubMed]
  14. A. Leray, K. Lillis, and J. Mertz, “Enhanced background rejection in thick tissue with differential-aberration two-photon microscopy,” Biophys. J.94(4), 1449–1458 (2008). [CrossRef] [PubMed]
  15. A. Leray, C. Odin, and Y. L. Grand, “Out-of-focus fluorescence collection in two-photon microscopy of scattering media,” Opt. Commun.281(24), 6139–6144 (2008). [CrossRef]
  16. S. A. Prahl, M. Keijzer, S. L. Jacques, and A. J. Welch, “A Monte Carlo model of light propagation in tissue,” Proc. SPIE IS 5, 102–111 (1989).
  17. L. Wang, S. L. Jacques, and L. Zheng, “MCML-Monte Carlo modeling of light transport in multi-layered tissues,” Comput. Methods Programs Biomed.47(2), 131–146 (1995). [CrossRef] [PubMed]
  18. Z. Wang, Z. Zhang, Z. Xu, and Q. Lin, “Space-time profile of an ultrashort pulsed Gaussian beam,” IEEE J. Quant. Electron.33(4), 566–573 (1997). [CrossRef]
  19. M. A. Porras, “Ultrashort pulsed Gaussian light beams,” Phys. Rev. E58(1), 1086–1093 (1998). [CrossRef]
  20. X. Fu, H. Guo, W. Hu, and S. Yu, “Spatial nonparaxial correction of the ultrashort pulsed beam propagation in free space,” Phys. Rev. E Stat. Nonlin. Soft Matter Phys.65(5), 056611 (2002). [CrossRef] [PubMed]
  21. C. Xu and W. W. Webb, “Measurement of two-photon excitation cross sections of molecular fluorophores with data from 690 to 1050 nm,” J. Opt. Soc. Am. B13(3), 481–491 (1996). [CrossRef]
  22. P. Theer, “On the fundamental imaging-depth limit in two-photon microscopy,” Dissertation, University of Heidelberg (2004).
  23. J. W. McLean, J. D. Freeman, and R. E. Walker, “Beam spread function with time dispersion,” Appl. Opt.37(21), 4701–4711 (1998). [CrossRef] [PubMed]
  24. A. K. Dunn, V. P. Wallace, M. Coleno, M. W. Berns, and B. J. Tromberg, “Influence of optical properties on two-photon fluorescence imaging in turbid samples,” Appl. Opt.39(7), 1194–1201 (2000). [CrossRef] [PubMed]
  25. M. Oheim, E. Beaurepaire, E. Chaigneau, J. Mertz, and S. Charpak, “Two-photon microscopy in brain tissue: parameters influencing the imaging depth,” J. Neurosci. Methods111(1), 29–37 (2001). [CrossRef] [PubMed]
  26. E. Beaurepaire and J. Mertz, “Epifluorescence collection in two-photon microscopy,” Appl. Opt.41(25), 5376–5382 (2002). [CrossRef] [PubMed]
  27. J. D. Jackson, “Classical Electrodynamics,” John Wiley & Sons, Inc., New York, (1999).
  28. C. Matzler, Matlab Functions for Mie Scattering and Absorption (Institut fur Angewandte Physik: University of Heidelberg 2004).
  29. J. P. Zinter and M. J. Levene, “Maximizing fluorescence collection efficiency in multiphoton microscopy,” Opt. Express19(16), 15348–15362 (2011). [CrossRef] [PubMed]
  30. W. W. Hell, G. Reiner, C. Cremer, and E. H. K. Stelzer, “Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index,” J. Microsc.169(3), 391–405 (1993). [CrossRef]
  31. S. G. Parra, T. H. Chia, J. P. Zinter, and M. J. Levene, “Multiphoton microscopy of cleared mouse organs,” J. Biomed. Opt.15(3), 036017 (2010). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited