OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 1, Iss. 7 — Jul. 17, 2006

Characterization of objective transmittance for optical tweezers

N. B. Viana, M. S. Rocha, O. N. Mesquita, A. Mazolli, and P. A. Maia Neto  »View Author Affiliations


Applied Optics, Vol. 45, Issue 18, pp. 4263-4269 (2006)
http://dx.doi.org/10.1364/AO.45.004263


View Full Text Article

Enhanced HTML    Acrobat PDF (547 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We have measured the overall transmittance of a laser beam through an oil immersion objective as a function of the transverse size of the laser beam, using the dual-objective method. Our results show that the objective transmittance is not uniform and that its dependence on the radial beam's position can be modeled by a Gaussian function. This property affects the intensity distribution pattern in the sample region and should be taken into account in theoretical descriptions of optical tweezers. Moreover, one must consider this position dependence to determine the local laser power delivered at the sample region by the dual-objective method, especially when the beam overfills the objective's back entrance. If the transmittance is assumed to be uniform, the local power is overestimated.

© 2006 Optical Society of America

OCIS Codes
(110.0180) Imaging systems : Microscopy
(120.0120) Instrumentation, measurement, and metrology : Instrumentation, measurement, and metrology
(120.4640) Instrumentation, measurement, and metrology : Optical instruments
(140.7010) Lasers and laser optics : Laser trapping

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: August 24, 2005
Revised Manuscript: October 17, 2005
Manuscript Accepted: November 18, 2005

Virtual Issues
Vol. 1, Iss. 7 Virtual Journal for Biomedical Optics

Citation
N. B. Viana, M. S. Rocha, O. N. Mesquita, A. Mazolli, and P. A. Maia Neto, "Characterization of objective transmittance for optical tweezers," Appl. Opt. 45, 4263-4269 (2006)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ao-45-18-4263


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. Ashkin and J. M. Dziedzic, "Optical trapping and manipulation of viruses and bacteria," Science 235, 1517-1520 (1987). [CrossRef] [PubMed]
  2. K. C. Neuman and S. M. Block, "Optical trapping," Rev. Sci. Instrum. 75, 2787-2809 (2004). [CrossRef]
  3. A. Mazolli, P. A. Maia Neto, and H. M. Nussenzveig, "Theory of trapping forces in optical tweezers," Proc. R. Soc. London Ser. A 459, 3021-3041 (2003). [CrossRef]
  4. B. Richards and E. Wolf, "Electromagnetic diffraction in optical systems. 2. Structure of the image field in an aplanatic system," Proc. R. Soc. London Ser. A 253, 358-379 (1959). [CrossRef]
  5. C. J. R. Sheppard and P. Török, "Effects of specimen refractive index on confocal imaging," J. Microsc. 185, 366-374 (1997). [CrossRef]
  6. D. Ganic, X. Gan, and M. Gu, "Exact radiation trapping force calculation based on vectorial diffraction theory," Opt. Express 12, 2670-2675 (2004). [CrossRef] [PubMed]
  7. N. B. Viana, M. S. Rocha, O. N. Mesquita, A. Mazolli, P. A. Maia Neto, and H. M. Nussenzveig, "Absolute calibration of optical tweezers," Appl. Phys. Lett. 88, 131110 (2006).
  8. H. Misawa, M. Koshioka, K. Sasak, N. Kitamura, and H. Masuhara, "3-Dimensional optical trapping and laser ablation of a single polymer latex particle in water," J. App. Phys. 70, 3829-3836 (1991). [CrossRef]
  9. A. Ashkin, "Forces of a single-beam gradient laser trap on a dielectric sphere in the ray optics regime," Biophys. J. 61, 569-582 (1992). [CrossRef] [PubMed]
  10. N. B. Viana, O. N. Mesquita, and A. Mazolli, "In situ measurement of laser power at the focus of a high numerical aperture objective using a microbolometer," Appl. Phys. Lett. 81, 1765-1767 (2002). [CrossRef]
  11. If the refractive index of sample chamber nS is smaller than the numerical aperture NA, then the rays at a distance p > ≥ Rc = nSRobj/NA from the axis are eliminated by total internal reflection. This is the case for water samples (nS = 1.33) with objectives of 1.4 NA. In this case we could substitute Rc for Robj throughout this section. However, the effect of this replacement is negligible because of the transmittance decay for large radial distances. For instance, Eq. (9) would yield, with Rc instead of Robj, an output power smaller by only 2%.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited