OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 2, Iss. 5 — May. 17, 2007

Multiscan time-domain optical coherence tomography for retina imaging

Carla Carmelo Rosa, John Rogers, Justin Pedro, Richard Rosen, and Adrian Podoleanu  »View Author Affiliations


Applied Optics, Vol. 46, Issue 10, pp. 1795-1808 (2007)
http://dx.doi.org/10.1364/AO.46.001795


View Full Text Article

Enhanced HTML    Acrobat PDF (877 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A versatile time-domain optical coherence tomography system is presented that can generate cross-sectional images by using either transverse priority or depth priority scanning. This is made possible by using a transmissive scanning delay line compatible with balance detection operating at a speed similar to that of the transverse scanner used to scan the beam across the target. In vivo images from the retina are generated and shown using the same system switched to either transverse or depth priority scanning regime, by using the scanning delay line either in slow or fast scanning modes, respectively. A comparative analysis of different scanning regimes depending on image size to fit different areas to be imaged is presented. Safety thresholds due to the different continuous irradiation time per transverse pixel in different scanning regimes are also considered. We present the maximum exposure level for a variety of scanning procedures, employing either A scanning (depth priority) or T scanning (transverse priority) when generating cross-sectional images, en face images, or collecting 3D volumes.

© 2007 Optical Society of America

OCIS Codes
(110.4500) Imaging systems : Optical coherence tomography
(170.4470) Medical optics and biotechnology : Ophthalmology
(170.4500) Medical optics and biotechnology : Optical coherence tomography
(180.5810) Microscopy : Scanning microscopy

ToC Category:
Optical Coherence Tomography

History
Original Manuscript: July 10, 2006
Revised Manuscript: November 14, 2006
Manuscript Accepted: December 18, 2006
Published: March 13, 2007

Virtual Issues
Vol. 2, Iss. 5 Virtual Journal for Biomedical Optics

Citation
Carla Carmelo Rosa, John Rogers, Justin Pedro, Richard Rosen, and Adrian Podoleanu, "Multiscan time-domain optical coherence tomography for retina imaging," Appl. Opt. 46, 1795-1808 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ao-46-10-1795


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. F. Fercher, W. Drexler, C. K. Hitzenberger, and T. Lasser, "Optical coherence tomography--principles and applications," Rep. Prog. Phys. 66, 239-303 (2003). [CrossRef]
  2. A. D. Aguirre, P. Hsiung, T. H. Ko, I. Hartl, and J. G. Fujimoto, "High-resolution optical coherence microscopy for high-speed, in vivo cellular imaging," Opt. Lett. 28, 2064-2066 (2003). [CrossRef] [PubMed]
  3. J. Schmitt, S. L. Lee, and K. M. Yung, "An optical coherence microscope with enhanced resolving power in thick tissue," Opt. Commun. 142, 203-207 (1997). [CrossRef]
  4. Y. Zhang, B. Cense, J. Rha, R. S. Jonnal, W. Gao, R. J. Zawadzki, J. S. Werner, S. Jones, S. Olivier, and D. T. Miller, "High-speed volumetric imaging of cone photoreceptors with adaptive optics spectral-domain optical coherence tomography," Opt. Express 14, 4380-4394 (2006). [CrossRef] [PubMed]
  5. C. C. Rosa, J. Rogers, and A. G. Podoleanu, "Fast scanning transmissive delay line for optical coherence tomography," Opt. Lett. 30, 3263-3265 (2005). [CrossRef]
  6. D. Huang, E. Swanson, C. Lin, J. Schuman, W. Stinson, W. Chang, M. Hee, T. Flotte, K. Gregory, C. Puliafito, and J. G. Fujimoto, "Optical coherence tomography," Science 254, 1178-1181 (1991). [CrossRef] [PubMed]
  7. A. Podoleanu, G. Dobre, D. Webb, and D. Jackson, "Coherence imaging by use of a Newton rings sampling function," Opt. Lett. 21, 1789-1791 (1996). [CrossRef] [PubMed]
  8. C. C. Rosa, V. Shidlovski, J. A. Rogers, R. B. Rosen, and A. G. Podoleanu, "Broadband SLD-based source for retina investigations," Proc. SPIE 5690, 540-547 (2005). [CrossRef]
  9. G. J. Tearney, B. E. Bouma, and J. G. Fujimoto, "High-speed phase-and group-delay scanning with a grating-based phase control delay line," Opt. Lett. 22, 1811-1813 (1997). [CrossRef]
  10. C. C. Rosa and A. G. Podoleanu, "Limitation of the achievable signal-to-noise ratio in optical coherence tomography due to mismatch of the balanced receiver," Appl. Opt. 43, 4802-4815 (2004). [CrossRef] [PubMed]
  11. A. Podoleanu, G. Dobre, and D. Jackson, "En-face coherence imaging using galvanometer scanner modulation," Opt. Lett. 23, 147-149 (1998). [CrossRef]
  12. A. Podoleanu, M. Seeger, G. Dobre, D. Webb, D. Jackson, and F. Fitzke, "Transversal and longitudinal images from the retina of the living eye using low coherence reflectometry," J. Biomed. Opt. 3, 12-20 (1998). [CrossRef]
  13. A. G. H. Podoleanu, G. M. Dobre, D. J. Webb, and D. A. Jackson, "Simultaneous en-face imaging of two layers in human retina," Opt. Lett. 22, 1039-1041 (1997). [CrossRef] [PubMed]
  14. M. Mujat, R. C. Chan, B. Cense, B. H. Park, C. Joo, T. Akkin, T. C. Chen, and J. F. de Boer, "Retinal nerve fiber layer thickness map determined from optical coherence tomography images," Opt. Express 13, 9480-9491 (2005). [CrossRef] [PubMed]
  15. W. Drexler, U. Morgner, R. K. Ghanta, F. X. Kartner, J. S. Schuman, and J. G. Fujimoto, "Ultrahigh-resolution ophthalmic optical coherence tomography," Nat. Med. 7, 502-507 (2001). [CrossRef] [PubMed]
  16. J. M. Gorrand and M. F. C. Delori, "Reflectance and curvature of the inner limiting membrane at the foveola," J. Opt. Soc. Am. A 16, 1229-1237 (1999). [CrossRef]
  17. A. G. Podoleanu, G. M. Dobre, R. G. Cucu, R. Rosen, P. Garcia, J. Nieto, D. Will, R. Gentile, T. Muldoon, J. Walsh, L. A. Yannuzzi, Y. Fisher, D. Orlock, R. Weitz, J. A. Rogers, S. Dunne, and A. Boxer, "Combined multiplanar optical coherence tomography and confocal scanning ophthalmoscopy," J. Biomed. Opt. 9, 86-93 (2004). [CrossRef] [PubMed]
  18. A. G. Podoleanu, J. A. Rogers, and D. A. Jackson, "Three dimensional OCT images from retina and skin," Opt. Express 7, 292-298 (2000). [CrossRef] [PubMed]
  19. D. H. Sliney and M. A. Mainster, "Ophthalmic laser safety: tissue interactions, hazards, and protection," Lasers Ophthalmol. 11, 157-164 (1998).
  20. "Revision of guidelines on limits of exposure to laser radiation of wavelengths between 400 nm and 1.4 microm.," ICNRP-International Commission on Nonionizing Radiation Protection , Health Phys. 79431-440 (2000).
  21. "Safety of laser products--Part 1: Equipment classification, requirements and user's guide," International Electrotechnical Commission, 60825-1 (1997).
  22. American National Standard for Safe Use of Lasers, ANSI Z136.1 (2000).
  23. A. Roorda, F. Romero-Borja, W. J. Donnelly III, H. Queener, T. J. Hebert, and M. C. W. Campbell, "Adaptive optics scanning laser ophthalmoscopy," Opt. Express 10, 405-412 (2002). [PubMed]
  24. J. A. Izatt, M. R. Hee, G. M. Owen, E. A. Swanson, and J. G. Fujimoto, "Optical coherence microscopy in scattering media," Opt. Lett. 19, 590-593 (1994). [CrossRef] [PubMed]
  25. S. Murali and J. Rolland, "Dynamic-focusing microscope objective for optical coherence tomography," 63420H, P SOC PHOTO-OPT INS 6342: H3420-H3420 Parts 1-2 2006.
  26. V. X. D. Yang, Y. Mao, B. A. Standish, N. R. Munce, S. Chiu, D. Burnes, B. C. Wilson, I. A. Vitkin, P. A. Himmer, and D. L. Dickensheets, "Doppler optical coherence tomography with a micro-electro-mechanical membrane mirror for high-speed dynamic focus tracking," Opt. Lett. 31, 1262-1264 (2006). [CrossRef] [PubMed]
  27. R. Webb, Noninvasive Diagnostic Techniques in Ophthalmology, B.Masters, ed. (Springer-Verlag, 1990), Chap. 22, pp. 438-450. [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited