Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region

Masahiko Daimon and Akira Masumura  »View Author Affiliations


Applied Optics, Vol. 46, Issue 18, pp. 3811-3820 (2007)
http://dx.doi.org/10.1364/AO.46.003811


View Full Text Article

Enhanced HTML    Acrobat PDF (1091 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

By the minimum deviation method using a prism shaped cell, the absolute refractive indices of high-performance liquid chromatography distilled water were measured at the wavelengths from 1129 to 182   nm , at the temperature of 19   ° C , 21 .5   ° C , and 24   ° C , and then dn∕dt at 21 .5   ° C was calculated. The coefficients of the four-term Sellmeier dispersion formula were determined by using the refractive indices at each temperature. As a result of the comparison of our refractive index data in the visible wavelength region with the formula by Tilton et al. at the National Bureau of Standards in 1938, both the refractive index data corresponded within 6 × 10 6 . In the UV region, the absolute refractive index at 193.39   nm calculated by the data measured nearby the wavelengths from 200 to 190   nm was 1.436517 ( 21 .5   ° C ) . The value was lower by 9 × 10 5 or 10 × 10 5 than the data measured by Burnett et al. at the National Institute of Standards and Technology.

© 2007 Optical Society of America

OCIS Codes
(010.7340) Atmospheric and oceanic optics : Water
(120.4530) Instrumentation, measurement, and metrology : Optical constants
(120.5710) Instrumentation, measurement, and metrology : Refraction
(160.4760) Materials : Optical properties

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: December 8, 2006
Manuscript Accepted: February 5, 2007
Published: May 31, 2007

Virtual Issues
Vol. 2, Iss. 7 Virtual Journal for Biomedical Optics

Citation
Masahiko Daimon and Akira Masumura, "Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region," Appl. Opt. 46, 3811-3820 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ao-46-18-3811


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. I. Thormählen, J. Straub, and U. Grigull, "Refractive index of water and its dependence on wavelength, temperature, and density," J. Phys. Chem. Ref. Data 14, 933-945 (1985). [CrossRef]
  2. P. Schiebener, J. Straub, J. M. H. L. Sengers, and J. S. Gallagher, "Refractive index of water and steam as function of wavelength, temperature and density," J. Phys. Chem. Ref. Data 19, 677-717 (1990). [CrossRef]
  3. A. H. Harvey, J. S. Gallagher, and J. M. H. L. Sengers, "Revised formulation for the refractive index of water and steam as a function of wavelength, temperature and density," J. Phys. Chem. Ref. Data 27, 761-774 (1998). [CrossRef]
  4. L. W. Tilton and J. K. Taylor, "Refractive index and dispersion of distilled water for visible radiation at temperatures 0 to 60 °C," J. Res. Natl. Bur. Stand. 20, 419-477 (1938).
  5. J. H. Burnett and S. G. Kaplan, "Measurement of the refractive index and thermo-optic coefficient of water near 193 nm," J. Microlithogr., Microfabr., Microsyst. 3, 68-72 (2004). [CrossRef]
  6. G.-J. Ulbrich and J. Trede, "Goniometer-spectrometer for index of refraction measurements from the near UV through the IR," in Proc. SPIE 1327, 32-39 (1990).
  7. M. Daimon and A. Masumura, "High-accuracy measurements of the refractive index and its temperature coefficient of calcium fluoride in a wide wavelength range from 138 to 2326 nm," Appl. Opt. 41, 5275-5281 (2002). [CrossRef] [PubMed]
  8. J. Reader, N. Acquista, C. J. Sansonetti, and J. E. Sansonetti, "Wavelengths and intensities of a platinum/neon hollow cathode lamp in the region 1100-4000 Å," Astrophys. J. Suppl. Ser. 72, 831-866 (1990). [CrossRef]
  9. J. E. Sansonetti, C. J. Sansonetti, J. Reader, N. Acquista, A. M. Sansonetti, and R. A. Dragoset, "Atlas of the spectrum of a platinum/neon hollow-cathode lamp in the region 1130-4330 Å," http://physics.nist.gov/PhysRefData/platinum/contents.html.
  10. E. R. Peck and B. N. Khanna, "Dispersion of nitrogen," J. Opt. Soc. Am. 56, 1059-1063 (1966). [CrossRef]
  11. U. Griesmann and J. H. Burnett, "Refractivity of nitrogen gas in the vacuum ultraviolet," Opt. Lett. 24, 1699-1701 (1999). [CrossRef]
  12. J. Koch, "UÜber die dispersion des lichtes in gasförmigen körpern innerhalb des ultravioletten spektrums," Arkiv Mat. Astron. Fys. 9, 1-11 (1913).
  13. M. Halmann and I. Platzner, "Temperature dependence of absorption of liquid water in the far-ultraviolet region," J. Phys. Chem. 70, 580-581 (1966). [CrossRef]
  14. L. R. Painter, R. D. Birkhoff, and E. T. Arakawa, "Optical measurements of liquid water in the vacuum ultraviolet," J. Chem. Phys. 51, 243-251 (1969). [CrossRef]
  15. G. M. Hale and M. R. Querry, "Optical constants of water in the 200-nm to 200-μm wavelength region," Appl. Opt. 12, 555-563 (1973). [CrossRef] [PubMed]
  16. B. Edlén, "The refractive index of air," Metrologia 2, 71-80 (1966). [CrossRef]
  17. R. Gupta and S. G. Kaplan, "High accuracy ultraviolet index of refraction measurements using a Fourier transform spectrometer," J. Res. Natl. Inst. Stand. Technol. 108, 429-437 (2003).
  18. V. Kaufman and B. Edlén, "Reference wavelengths from atomic spectra in the range 15 Å to 25000 Å," J. Phys. Chem. Ref. Data 3, 825-895 (1974). [CrossRef]
  19. A. H. Harvey, S. G. Kaplan, and J. H. Burnett, "Effect of dissolved air on the density and refractive index of water," Int. J. Thermophys. 26, 1495-1514 (2005). [CrossRef]
  20. R. Gupta, J. H. Burnett, U. Griesmann, and M. Walhout, "Absolute refractive indices and thermal coefficients of fused silica and calcium fluoride near 193 nm," Appl. Opt. 37, 5964-5968 (1998). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited