OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 2, Iss. 10 — Oct. 31, 2007

Optimization of image-forming optics for transmission optical projection tomography

Yi Wang and Ruikang K. Wang  »View Author Affiliations


Applied Optics, Vol. 46, Issue 27, pp. 6815-6820 (2007)
http://dx.doi.org/10.1364/AO.46.006815


View Full Text Article

Enhanced HTML    Acrobat PDF (446 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A new optical system for transmission optical projection tomography (TOPT) is presented to reduce the divergence of the projection data from the true parallel projections. This is performed by introducing an iris at the back focus of the objective lens. The influence of the defocusing on TOPT is demonstrated by computational simulations and experiments. We compare the performances of the new and conventional TOPT systems in order to optimize the optical system for three-dimensional imaging of the embryos of small animals. The optimal imaging performance is given by the new system with numerical apertures between 0.007 and 0.014, with which the spatial resolution of 25 μm is achieved. The optimal configuration is validated by TOPT of a phantom sample and a fixed five-day chick embryo.

© 2007 Optical Society of America

OCIS Codes
(170.0110) Medical optics and biotechnology : Imaging systems
(170.3880) Medical optics and biotechnology : Medical and biological imaging

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: January 29, 2007
Revised Manuscript: June 20, 2007
Manuscript Accepted: June 23, 2007
Published: September 19, 2007

Virtual Issues
Vol. 2, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Yi Wang and Ruikang K. Wang, "Optimization of image-forming optics for transmission optical projection tomography," Appl. Opt. 46, 6815-6820 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ao-46-27-6815


Sort:  Year  |  Journal  |  Reset  

References

  1. J. Sharpe, U. Ahlgren, P. Perry, B. Hill, A. Ross, J. Hecksher-Sorensen, R. Baldock, and D. Davidson, "Optical projection tomography as a tool for 3D microscopy and gene expression studies," Science 296, 541-545 (2002). [CrossRef] [PubMed]
  2. J. Sharpe, U. Ahlgren, P. Perry, B. Hill, A. Ross, J. Hecksher-Sorensen, R. Baldock, and D. Davidson, Sci. Online at www.sciencemag.org/cgi/content/full/296/5567/541/DC1.
  3. R. J. Bryson Richardson and P. D. Currie, "Optical projection tomography for spatio-temporal analysis in the Zebrafish," Methods Cell Biol. 76, 37-50 (2004). [CrossRef]
  4. M. Oldham, H. Sakhalkar, Y. M. Wang, P. Guo, T. Oliver, R. Bentley, Z. Vujaskovic, and M. Dewhirst, "Three-dimensional imaging of whole rodent organs using optical computed and emission tomography," J. Biomed. Opt. 12, 014009-1-10 (2007). [CrossRef] [PubMed]
  5. M. Oldham, H. Sakhalkar, T. Oliver, Y. M. Wang, Y. Cao, C. Badea, G. A. Johnson, and M. Dewhirst, "Three dimensional imaging of xenograft tumors using optical computed and emission tomography," Med. Phys. 33, 3193-3202 (2006). [CrossRef] [PubMed]
  6. M. Oldham, T. Oliver, and M. Dewhirst, "Optical imaging of tumor microvasculature in 3D," Med. Phys. 32, 2134 (2005). [CrossRef]
  7. J. C. Gore, M. Ranade, M. J. Maryanski, and R. J. Schulz, "Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner," Phys. Med. Biol. 41, 2695-2704 (1996). [CrossRef] [PubMed]
  8. R. G. Kelly, K. J. Jordan, and J. J. Battista, "Optical CT reconstruction of 3-D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter," Med. Phys. 25, 1741-1750 (1998). [CrossRef] [PubMed]
  9. J. G. Wolodzko, C. Marsden, and A. Appleby, "CCD imaging for optical tomography of gel radiation dosimeters," Med. Phys. 26, 2508-2513 (1999). [CrossRef] [PubMed]
  10. S. J. Doran, K. K. Koerkamp, M. A. Bero, P. Jenneson, E. J. Morton, and W. B. Gilboy, "A CCD-based optical CT scanner for high-resolution 3-D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results," Phys. Med. Biol. 46, 3191-3213 (2001). [CrossRef]
  11. N. Krstajic and S. J. Doran, "Focusing optics of a parallel beam CCD optical tomography apparatus for 3-D radiation gel dosimetry," Phys. Med. Biol. 51, 2055-2075 (2006). [CrossRef] [PubMed]
  12. J. Kerwin, M. Scott, J. Sharpe, L. Puelles, S. C. Robson, M. Martnez-de-la-Torre, J. L. Ferran, G. Feng, R. A. Baldock, T. Strachan, D. Davidson, and S. Lindsay, "3 dimensional modelling of early human brain development using optical projection tomography," BMC Neurosci. 5, 27 (2004). [CrossRef] [PubMed]
  13. I. Von Both, C. Silvestri, T. Erdemir, H. Lickert, J. R. Walls, R. M. Henkelman, J. Rossant, R. P. Harvey, L. Attisano, and J. L. Wrana, "Foxh1 is essential for development of the anterior heart field," Developmental Cell 7, 331-345 (2004). [CrossRef] [PubMed]
  14. H. Lickert, J. K. Takeuchi, I. Von Both, J. R. Walls, F. McAuliffe, S. L. Adamson, R. M. Henkelman, J. L. Wrana, J. Rossant, and B. G. Bruneau, "Baf60c is essential for function of BAF chromatin remodelling complexes in heart development," Nature 432, 107-112 (2004). [CrossRef] [PubMed]
  15. Y. Wang and R. K. Wang, "Imaging using parallel integrals in optical projection tomography," Phys. Med. Biol. 51, 6023-6032 (2006). [CrossRef] [PubMed]
  16. J. R. Walls, J. G. Sled, J. Sharpe, and R. M. Henkelman, "Correction of artefacts in optical projection tomography," Phys. Med. Biol. 50, 4645-4665 (2005). [CrossRef] [PubMed]
  17. M. Xu and L. H. Wang, "Time-domain reconstruction for thermoacoustic tomography in a spherical geometry," IEEE Trans. Med. Imaging 21, 814-822 (2002). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4 Fig. 5
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited